Search criteria
17 vulnerabilities found for w18e by tenda
VAR-202505-3617
Vulnerability from variot - Updated: 2025-06-05 23:09An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code via the editing functionality of the account module in the goform/setmodules route. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware contains an access control vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202505-3617",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.11\\(2044\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.11(2044)"
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"cve": "CVE-2025-45343",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-45343",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-006174",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-45343",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2025-006174",
"trust": 0.8,
"value": "Critical"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code via the editing functionality of the account module in the goform/setmodules route. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware contains an access control vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-45343"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-45343",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2025-006174",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"id": "VAR-202505-3617",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5833333
},
"last_update_date": "2025-06-05T23:09:33.487000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-284",
"trust": 1.0
},
{
"problemtype": "Inappropriate access control (CWE-284) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "http://w18e.com"
},
{
"trust": 1.8,
"url": "https://gist.github.com/isstabber/b363d47966965e5c0a8ec26d445e090b"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-45343"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-04T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"date": "2025-05-28T16:15:33.240000",
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-04T01:47:00",
"db": "JVNDB",
"id": "JVNDB-2025-006174"
},
{
"date": "2025-06-03T15:36:32.347000",
"db": "NVD",
"id": "CVE-2025-45343"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Access control vulnerabilities in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-006174"
}
],
"trust": 0.8
}
}
VAR-202504-0831
Vulnerability from variot - Updated: 2025-05-15 23:07A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of w18e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Attackers can exploit this vulnerability to cause the program to crash
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202504-0831",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.11"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.11"
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.01.0.11"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09666"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"cve": "CVE-2025-3203",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-3203",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Partial",
"baseScore": 4.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-003110",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-09666",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2025-3203",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 4.3,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-003110",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-3203",
"trust": 1.0,
"value": "Medium"
},
{
"author": "OTHER",
"id": "JVNDB-2025-003110",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-09666",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09666"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of w18e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Attackers can exploit this vulnerability to cause the program to crash",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-3203"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"db": "CNVD",
"id": "CNVD-2025-09666"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-3203",
"trust": 3.2
},
{
"db": "VULDB",
"id": "303157",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003110",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09666",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09666"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"id": "VAR-202504-0831",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09666"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09666"
}
]
},
"last_update_date": "2025-05-15T23:07:33.097000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://vuldb.com/?id.303157"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.545883"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-3203"
},
{
"trust": 1.0,
"url": "https://github.com/zikh26/tmp_store_reports/blob/main/tenda-w18e.md"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.303157"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09666"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09666"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09666"
},
{
"date": "2025-04-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"date": "2025-04-04T03:15:14.207000",
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09666"
},
{
"date": "2025-04-09T08:28:00",
"db": "JVNDB",
"id": "JVNDB-2025-003110"
},
{
"date": "2025-04-08T13:41:35.810000",
"db": "NVD",
"id": "CVE-2025-3203"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-003110"
}
],
"trust": 0.8
}
}
VAR-202310-1257
Vulnerability from variot - Updated: 2025-05-13 23:19Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function. Tenda W18E is a wireless router from China's Tenda company. Attackers can exploit this vulnerability to execute arbitrary commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202310-1257",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1576\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.01.0.8(1576)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"cve": "CVE-2023-46370",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-09405",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-46370",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-46370",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2025-09405",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function. Tenda W18E is a wireless router from China\u0027s Tenda company. Attackers can exploit this vulnerability to execute arbitrary commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46370"
},
{
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"db": "VULMON",
"id": "CVE-2023-46370"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-46370",
"trust": 1.7
},
{
"db": "CNVD",
"id": "CNVD-2025-09405",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-46370",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"db": "VULMON",
"id": "CVE-2023-46370"
},
{
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"id": "VAR-202310-1257",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
}
]
},
"last_update_date": "2025-05-13T23:19:19.547000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.1,
"url": "https://github.com/archerber/bug_submit/blob/main/tenda/w18e/bug2.md"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-46370"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"db": "VULMON",
"id": "CVE-2023-46370"
},
{
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"db": "VULMON",
"id": "CVE-2023-46370"
},
{
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"date": "2023-10-25T00:00:00",
"db": "VULMON",
"id": "CVE-2023-46370"
},
{
"date": "2023-10-25T18:17:37.830000",
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09405"
},
{
"date": "2023-10-25T00:00:00",
"db": "VULMON",
"id": "CVE-2023-46370"
},
{
"date": "2023-11-01T20:05:45.640000",
"db": "NVD",
"id": "CVE-2023-46370"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E Command Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09405"
}
],
"trust": 0.6
}
}
VAR-202502-1335
Vulnerability from variot - Updated: 2025-05-13 23:11A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unauthenticated remote attacker to retrieve sensitive configuration information, including WiFi SSID, WiFi password, and base64-encoded administrator credentials, by sending a specially crafted HTTP POST request to the getQuickCfgWifiAndLogin function, bypassing authentication checks. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware has an information disclosure vulnerability.Information may be obtained.
Tenda W18E version 16.01.0.8(1625) has an information leakage vulnerability. The vulnerability is caused by the application's insufficient protection of sensitive information. Attackers can exploit this vulnerability to retrieve sensitive configuration information
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-1335",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09404"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"cve": "CVE-2024-46437",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-09404",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-46437",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020902",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46437",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020902",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-09404",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09404"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unauthenticated remote attacker to retrieve sensitive configuration information, including WiFi SSID, WiFi password, and base64-encoded administrator credentials, by sending a specially crafted HTTP POST request to the getQuickCfgWifiAndLogin function, bypassing authentication checks. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware has an information disclosure vulnerability.Information may be obtained. \n\nTenda W18E version 16.01.0.8(1625) has an information leakage vulnerability. The vulnerability is caused by the application\u0027s insufficient protection of sensitive information. Attackers can exploit this vulnerability to retrieve sensitive configuration information",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46437"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"db": "CNVD",
"id": "CNVD-2025-09404"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46437",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020902",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09404",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09404"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"id": "VAR-202502-1335",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09404"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09404"
}
]
},
"last_update_date": "2025-05-13T23:11:26.312000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.0
},
{
"problemtype": "information leak (CWE-200) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46437"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09404"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09404"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09404"
},
{
"date": "2025-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"date": "2025-02-10T19:15:39.200000",
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09404"
},
{
"date": "2025-03-26T00:36:00",
"db": "JVNDB",
"id": "JVNDB-2024-020902"
},
{
"date": "2025-03-25T17:38:44.810000",
"db": "NVD",
"id": "CVE-2024-46437"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Information disclosure vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020902"
}
],
"trust": 0.8
}
}
VAR-202502-0765
Vulnerability from variot - Updated: 2025-05-13 23:06A default credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using the default rzadmin account with administrative privileges. Shenzhen Tenda Technology Co.,Ltd. of w18e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-0765",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09402"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"cve": "CVE-2024-46433",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-09402",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-46433",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020921",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46433",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020921",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-09402",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09402"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A default credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using the default rzadmin account with administrative privileges. Shenzhen Tenda Technology Co.,Ltd. of w18e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46433"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"db": "CNVD",
"id": "CNVD-2025-09402"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46433",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020921",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09402",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09402"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"id": "VAR-202502-0765",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09402"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09402"
}
]
},
"last_update_date": "2025-05-13T23:06:39.253000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Use hard-coded credentials (CWE-798) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46433"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09402"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09402"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09402"
},
{
"date": "2025-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"date": "2025-02-10T19:15:38.683000",
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09402"
},
{
"date": "2025-03-26T02:10:00",
"db": "JVNDB",
"id": "JVNDB-2024-020921"
},
{
"date": "2025-03-25T18:13:12.293000",
"db": "NVD",
"id": "CVE-2024-46433"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020921"
}
],
"trust": 0.8
}
}
VAR-202502-1624
Vulnerability from variot - Updated: 2025-05-13 23:06A hardcoded credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using a default guest account with administrative privileges. Shenzhen Tenda Technology Co.,Ltd. of w18e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-1624",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09403"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"cve": "CVE-2024-46429",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-09403",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-46429",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-021131",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46429",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-021131",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-09403",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09403"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A hardcoded credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using a default guest account with administrative privileges. Shenzhen Tenda Technology Co.,Ltd. of w18e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46429"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"db": "CNVD",
"id": "CNVD-2025-09403"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46429",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021131",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09403",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09403"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"id": "VAR-202502-1624",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09403"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09403"
}
]
},
"last_update_date": "2025-05-13T23:06:39.205000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Use hard-coded credentials (CWE-798) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46429"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09403"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09403"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09403"
},
{
"date": "2025-04-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"date": "2025-02-10T19:15:38.153000",
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09403"
},
{
"date": "2025-04-01T04:16:00",
"db": "JVNDB",
"id": "JVNDB-2024-021131"
},
{
"date": "2025-03-28T18:21:38.930000",
"db": "NVD",
"id": "CVE-2024-46429"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-021131"
}
],
"trust": 0.8
}
}
VAR-202502-0396
Vulnerability from variot - Updated: 2025-05-13 23:03Tenda W18E V16.01.0.8(1625) is vulnerable to Buffer Overflow. An attacker with access to the web management portal can exploit this vulnerability by sending specially crafted data to the delWewifiPic function. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
Tenda W18E has a buffer overflow vulnerability, which is caused by the delWewifiPic function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-0396",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09400"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"cve": "CVE-2024-46431",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.7,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 5.1,
"id": "CNVD-2025-09400",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2024-46431",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.0,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020922",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46431",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020922",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-09400",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09400"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E V16.01.0.8(1625) is vulnerable to Buffer Overflow. An attacker with access to the web management portal can exploit this vulnerability by sending specially crafted data to the delWewifiPic function. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda W18E has a buffer overflow vulnerability, which is caused by the delWewifiPic function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46431"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"db": "CNVD",
"id": "CNVD-2025-09400"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46431",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020922",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09400",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09400"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"id": "VAR-202502-0396",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09400"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09400"
}
]
},
"last_update_date": "2025-05-13T23:03:35.639000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46431"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09400"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09400"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09400"
},
{
"date": "2025-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"date": "2025-02-10T19:15:38.390000",
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09400"
},
{
"date": "2025-03-26T02:10:00",
"db": "JVNDB",
"id": "JVNDB-2024-020922"
},
{
"date": "2025-03-25T18:12:49.380000",
"db": "NVD",
"id": "CVE-2024-46431"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Classic buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020922"
}
],
"trust": 0.8
}
}
VAR-202502-1067
Vulnerability from variot - Updated: 2025-05-13 19:36Hardcoded credentials in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to gain root access to the device over the telnet service. Shenzhen Tenda Technology Co.,Ltd. of w18e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
Tenda W18E has a trust management vulnerability, which is caused by the existence of hard-coded credentials. No detailed vulnerability details are currently available
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-1067",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09401"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"cve": "CVE-2024-46436",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 8.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-09401",
"impactScore": 9.5,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-46436",
"impactScore": 5.5,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 8.3,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020931",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46436",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020931",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-09401",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09401"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Hardcoded credentials in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to gain root access to the device over the telnet service. Shenzhen Tenda Technology Co.,Ltd. of w18e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda W18E has a trust management vulnerability, which is caused by the existence of hard-coded credentials. No detailed vulnerability details are currently available",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46436"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"db": "CNVD",
"id": "CNVD-2025-09401"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46436",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020931",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09401",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09401"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"id": "VAR-202502-1067",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09401"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09401"
}
]
},
"last_update_date": "2025-05-13T19:36:20.801000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Use hard-coded credentials (CWE-798) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46436"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09401"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09401"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09401"
},
{
"date": "2025-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"date": "2025-02-10T19:15:39.063000",
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09401"
},
{
"date": "2025-03-26T03:12:00",
"db": "JVNDB",
"id": "JVNDB-2024-020931"
},
{
"date": "2025-03-25T17:38:52.737000",
"db": "NVD",
"id": "CVE-2024-46436"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020931"
}
],
"trust": 0.8
}
}
VAR-202503-2702
Vulnerability from variot - Updated: 2025-04-26 22:56Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. Shenzhen Tenda Technology Co.,Ltd. of w18e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202503-2702",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.11"
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.11"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.01.0.11"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "2.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08313"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"cve": "CVE-2025-29217",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-08313",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2025-29217",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-002630",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-29217",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2025-002630",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-08313",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08313"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. Shenzhen Tenda Technology Co.,Ltd. of w18e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-29217"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"db": "CNVD",
"id": "CNVD-2025-08313"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-29217",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002630",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-08313",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08313"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"id": "VAR-202503-2702",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08313"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08313"
}
]
},
"last_update_date": "2025-04-26T22:56:01.168000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "http://w18e.com"
},
{
"trust": 1.8,
"url": "https://gist.github.com/isstabber/d170f68bd85ed97e66ff316e57634b99"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-29217"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08313"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-08313"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08313"
},
{
"date": "2025-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"date": "2025-03-20T19:15:37.680000",
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08313"
},
{
"date": "2025-03-27T02:12:00",
"db": "JVNDB",
"id": "JVNDB-2025-002630"
},
{
"date": "2025-03-25T17:38:28.670000",
"db": "NVD",
"id": "CVE-2025-29217"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002630"
}
],
"trust": 0.8
}
}
VAR-202503-2695
Vulnerability from variot - Updated: 2025-04-26 22:48Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. Shenzhen Tenda Technology Co.,Ltd. of w18e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202503-2695",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.11"
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.11"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.01.0.11"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "2.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08312"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"cve": "CVE-2025-29218",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-08312",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2025-29218",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-002624",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-29218",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2025-002624",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-08312",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08312"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. Shenzhen Tenda Technology Co.,Ltd. of w18e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-29218"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"db": "CNVD",
"id": "CNVD-2025-08312"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-29218",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002624",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-08312",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08312"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"id": "VAR-202503-2695",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08312"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08312"
}
]
},
"last_update_date": "2025-04-26T22:48:09.811000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://gist.github.com/isstabber/a03c9dc3e89d5cf3b9e46dbef1ee5bf1"
},
{
"trust": 1.8,
"url": "https://github.com/isstabber/my_vulnhub/blob/main/tendaw18ev2/poc_wifipwd_stack_overflow.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-29218"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08312"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-08312"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08312"
},
{
"date": "2025-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"date": "2025-03-20T19:15:37.790000",
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08312"
},
{
"date": "2025-03-27T01:26:00",
"db": "JVNDB",
"id": "JVNDB-2025-002624"
},
{
"date": "2025-03-26T18:23:20.987000",
"db": "NVD",
"id": "CVE-2025-29218"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002624"
}
],
"trust": 0.8
}
}
VAR-202502-0633
Vulnerability from variot - Updated: 2025-03-28 23:31Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. An attacker can send a specially crafted HTTP POST request to the setQuickCfgWifiAndLogin function, which allows unauthorized changes to WiFi configuration settings and administrative credentials. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware contains an access control vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-0633",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05374"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"cve": "CVE-2024-46432",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-05374",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-46432",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020988",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46432",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020988",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-05374",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05374"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. An attacker can send a specially crafted HTTP POST request to the setQuickCfgWifiAndLogin function, which allows unauthorized changes to WiFi configuration settings and administrative credentials. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware contains an access control vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46432"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"db": "CNVD",
"id": "CNVD-2025-05374"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46432",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020988",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-05374",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05374"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"id": "VAR-202502-0633",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05374"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05374"
}
]
},
"last_update_date": "2025-03-28T23:31:22.107000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-284",
"trust": 1.0
},
{
"problemtype": "Inappropriate access control (CWE-284) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46432"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05374"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-05374"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05374"
},
{
"date": "2025-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"date": "2025-02-10T19:15:38.540000",
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05374"
},
{
"date": "2025-03-27T02:30:00",
"db": "JVNDB",
"id": "JVNDB-2024-020988"
},
{
"date": "2025-03-25T18:13:06.687000",
"db": "NVD",
"id": "CVE-2024-46432"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Access control vulnerabilities in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020988"
}
],
"trust": 0.8
}
}
VAR-202502-0512
Vulnerability from variot - Updated: 2025-03-28 23:29A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote attacker to cause a denial of service or potentially execute arbitrary code. This vulnerability occurs due to improper input validation when handling user-supplied data in the delFacebookPic function. Shenzhen Tenda Technology Co.,Ltd. of w18e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
There is a buffer overflow vulnerability in the Tenda W18E 16.01.0.8 (1625) version
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-0512",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05372"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"cve": "CVE-2024-46435",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.7,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 5.1,
"id": "CNVD-2025-05372",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2024-46435",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.0,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020979",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46435",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020979",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-05372",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05372"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote attacker to cause a denial of service or potentially execute arbitrary code. This vulnerability occurs due to improper input validation when handling user-supplied data in the delFacebookPic function. Shenzhen Tenda Technology Co.,Ltd. of w18e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nThere is a buffer overflow vulnerability in the Tenda W18E 16.01.0.8 (1625) version",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46435"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"db": "CNVD",
"id": "CNVD-2025-05372"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46435",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020979",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-05372",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05372"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"id": "VAR-202502-0512",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05372"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05372"
}
]
},
"last_update_date": "2025-03-28T23:29:01.313000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46435"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05372"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-05372"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05372"
},
{
"date": "2025-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"date": "2025-02-10T19:15:38.930000",
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05372"
},
{
"date": "2025-03-27T02:12:00",
"db": "JVNDB",
"id": "JVNDB-2024-020979"
},
{
"date": "2025-03-25T17:38:59.910000",
"db": "NVD",
"id": "CVE-2024-46435"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020979"
}
],
"trust": 0.8
}
}
VAR-202502-0923
Vulnerability from variot - Updated: 2025-03-28 23:21Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request. Shenzhen Tenda Technology Co.,Ltd. of w18e An authentication vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
Tenda W18E 16.01.0.8(1625) version has an authorization issue vulnerability. The vulnerability is caused by improper authentication of the device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-0923",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05370"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"cve": "CVE-2024-46434",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-05370",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-46434",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020987",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46434",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020987",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-05370",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05370"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request. Shenzhen Tenda Technology Co.,Ltd. of w18e An authentication vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda W18E 16.01.0.8(1625) version has an authorization issue vulnerability. The vulnerability is caused by improper authentication of the device",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46434"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"db": "CNVD",
"id": "CNVD-2025-05370"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46434",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020987",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-05370",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05370"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"id": "VAR-202502-0923",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05370"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05370"
}
]
},
"last_update_date": "2025-03-28T23:21:56.007000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.0
},
{
"problemtype": "Inappropriate authentication (CWE-287) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46434"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05370"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-05370"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05370"
},
{
"date": "2025-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"date": "2025-02-10T19:15:38.803000",
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05370"
},
{
"date": "2025-03-27T02:30:00",
"db": "JVNDB",
"id": "JVNDB-2024-020987"
},
{
"date": "2025-03-25T18:13:15.993000",
"db": "NVD",
"id": "CVE-2024-46434"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Authentication vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020987"
}
],
"trust": 0.8
}
}
VAR-202502-1491
Vulnerability from variot - Updated: 2025-03-28 02:52Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism. Shenzhen Tenda Technology Co.,Ltd
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-1491",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1625\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w18e firmware 16.01.0.8(1625)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.8(1625)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05373"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"cve": "CVE-2024-46430",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-05373",
"impactScore": 6.9,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:C/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2024-46430",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-020903",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46430",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020903",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-05373",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05373"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism. Shenzhen Tenda Technology Co.,Ltd",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46430"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"db": "CNVD",
"id": "CNVD-2025-05373"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46430",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020903",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-05373",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05373"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"id": "VAR-202502-1491",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05373"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05373"
}
]
},
"last_update_date": "2025-03-28T02:52:25.158000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-284",
"trust": 1.0
},
{
"problemtype": "Inappropriate access control (CWE-284) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46430"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05373"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-05373"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05373"
},
{
"date": "2025-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"date": "2025-02-10T19:15:38.273000",
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05373"
},
{
"date": "2025-03-26T00:36:00",
"db": "JVNDB",
"id": "JVNDB-2024-020903"
},
{
"date": "2025-03-25T18:12:41.753000",
"db": "NVD",
"id": "CVE-2024-46430"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w18e\u00a0 Access control vulnerabilities in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020903"
}
],
"trust": 0.8
}
}
VAR-202310-1075
Vulnerability from variot - Updated: 2024-09-12 23:25Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function. Tenda W18E is a wireless router from China's Tenda company. The vulnerability is caused by the portMirrorMirroredPorts parameter in the formSetNetCheckTools function failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202310-1075",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w18e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8\\(1576\\)"
},
{
"model": "w18e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.01.0.8(1576)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"cve": "CVE-2023-46369",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-20280",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-46369",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-46369",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-46369",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-20280",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"db": "NVD",
"id": "CVE-2023-46369"
},
{
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function. Tenda W18E is a wireless router from China\u0027s Tenda company. The vulnerability is caused by the portMirrorMirroredPorts parameter in the formSetNetCheckTools function failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46369"
},
{
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"db": "VULMON",
"id": "CVE-2023-46369"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-46369",
"trust": 1.7
},
{
"db": "CNVD",
"id": "CNVD-2024-20280",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-46369",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"db": "VULMON",
"id": "CVE-2023-46369"
},
{
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"id": "VAR-202310-1075",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
}
],
"trust": 1.1833333000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
}
]
},
"last_update_date": "2024-09-12T23:25:11.482000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.1,
"url": "https://github.com/archerber/bug_submit/blob/main/tenda/w18e/bug1.md"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-46369"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"db": "VULMON",
"id": "CVE-2023-46369"
},
{
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"db": "VULMON",
"id": "CVE-2023-46369"
},
{
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-04-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"date": "2023-10-25T00:00:00",
"db": "VULMON",
"id": "CVE-2023-46369"
},
{
"date": "2023-10-25T18:17:37.790000",
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-04-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-20280"
},
{
"date": "2023-10-25T00:00:00",
"db": "VULMON",
"id": "CVE-2023-46369"
},
{
"date": "2024-09-11T18:35:12.640000",
"db": "NVD",
"id": "CVE-2023-46369"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W18E Buffer Overflow Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-20280"
}
],
"trust": 0.6
}
}
CVE-2025-3203 (GCVE-0-2025-3203)
Vulnerability from nvd – Published: 2025-04-04 02:31 – Updated: 2025-04-04 15:45| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3203",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T15:44:52.340781Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T15:45:15.623Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "W18E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.11"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ZIKH26 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda W18E 16.01.0.11 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion formSetAccountList der Datei /goform/setModules. Durch Manipulieren des Arguments Password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T02:31:09.829Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303157 | Tenda W18E setModules formSetAccountList stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.303157"
},
{
"name": "VDB-303157 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303157"
},
{
"name": "Submit #545883 | Tenda W18E W18E V2.0-V16.01.0.11 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.545883"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T15:02:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W18E setModules formSetAccountList stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3203",
"datePublished": "2025-04-04T02:31:09.829Z",
"dateReserved": "2025-04-03T12:57:22.556Z",
"dateUpdated": "2025-04-04T15:45:15.623Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3203 (GCVE-0-2025-3203)
Vulnerability from cvelistv5 – Published: 2025-04-04 02:31 – Updated: 2025-04-04 15:45| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3203",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T15:44:52.340781Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T15:45:15.623Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "W18E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.11"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ZIKH26 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda W18E 16.01.0.11 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion formSetAccountList der Datei /goform/setModules. Durch Manipulieren des Arguments Password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T02:31:09.829Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303157 | Tenda W18E setModules formSetAccountList stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.303157"
},
{
"name": "VDB-303157 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303157"
},
{
"name": "Submit #545883 | Tenda W18E W18E V2.0-V16.01.0.11 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.545883"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T15:02:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W18E setModules formSetAccountList stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3203",
"datePublished": "2025-04-04T02:31:09.829Z",
"dateReserved": "2025-04-03T12:57:22.556Z",
"dateUpdated": "2025-04-04T15:45:15.623Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",