Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for vnc_viewer by realvnc

    CVE-2022-41975 (GCVE-0-2022-41975)

    Vulnerability from nvd – Published: 2022-09-30 17:20 – Updated: 2025-05-20 16:02
    VLAI
    Summary
    RealVNC VNC Server before 6.11.0 and VNC Viewer before 6.22.826 on Windows allow local privilege escalation via MSI installer Repair mode.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-269 - Improper Privilege Management
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:56:39.201Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-41975",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-20T16:02:46.823279Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-20T16:02:59.158Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "RealVNC VNC Server before 6.11.0 and VNC Viewer before 6.22.826 on Windows allow local privilege escalation via MSI installer Repair mode."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-30T17:20:33.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-41975",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "RealVNC VNC Server before 6.11.0 and VNC Viewer before 6.22.826 on Windows allow local privilege escalation via MSI installer Repair mode."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2",
                  "refsource": "MISC",
                  "url": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-41975",
        "datePublished": "2022-09-30T17:20:33.000Z",
        "dateReserved": "2022-09-30T00:00:00.000Z",
        "dateUpdated": "2025-05-20T16:02:59.158Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-41380 (GCVE-0-2021-41380)

    Vulnerability from nvd – Published: 2021-09-17 19:14 – Updated: 2024-08-04 03:08 Disputed
    VLAI
    Summary
    RealVNC Viewer 6.21.406 allows remote VNC servers to cause a denial of service (application crash) via crafted RFB protocol data. NOTE: It is asserted that this issue requires social engineering a user into connecting to a fake VNC Server. The VNC Viewer application they are using will then hang, until terminated, but no memory leak occurs - the resources are freed once the hung process is terminated and the resource usage is constant during the hang. Only the process that is connected to the fake Server is affected. This is an application bug, not a security issue
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T03:08:32.392Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "RealVNC Viewer 6.21.406 allows remote VNC servers to cause a denial of service (application crash) via crafted RFB protocol data. NOTE: It is asserted that this issue requires social engineering a user into connecting to a fake VNC Server. The VNC Viewer application they are using will then hang, until terminated, but no memory leak occurs - the resources are freed once the hung process is terminated and the resource usage is constant during the hang. Only the process that is connected to the fake Server is affected. This is an application bug, not a security issue"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-24T15:34:47.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41380",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** RealVNC Viewer 6.21.406 allows remote VNC servers to cause a denial of service (application crash) via crafted RFB protocol data. NOTE: It is asserted that this issue requires social engineering a user into connecting to a fake VNC Server. The VNC Viewer application they are using will then hang, until terminated, but no memory leak occurs - the resources are freed once the hung process is terminated and the resource usage is constant during the hang. Only the process that is connected to the fake Server is affected. This is an application bug, not a security issue."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03",
                  "refsource": "MISC",
                  "url": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41380",
        "datePublished": "2021-09-17T19:14:44.000Z",
        "dateReserved": "2021-09-17T00:00:00.000Z",
        "dateUpdated": "2024-08-04T03:08:32.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-41975 (GCVE-0-2022-41975)

    Vulnerability from cvelistv5 – Published: 2022-09-30 17:20 – Updated: 2025-05-20 16:02
    VLAI
    Summary
    RealVNC VNC Server before 6.11.0 and VNC Viewer before 6.22.826 on Windows allow local privilege escalation via MSI installer Repair mode.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-269 - Improper Privilege Management
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:56:39.201Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-41975",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-20T16:02:46.823279Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-20T16:02:59.158Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "RealVNC VNC Server before 6.11.0 and VNC Viewer before 6.22.826 on Windows allow local privilege escalation via MSI installer Repair mode."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-30T17:20:33.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-41975",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "RealVNC VNC Server before 6.11.0 and VNC Viewer before 6.22.826 on Windows allow local privilege escalation via MSI installer Repair mode."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2",
                  "refsource": "MISC",
                  "url": "https://help.realvnc.com/hc/en-us/articles/360002253138-Release-Notes#vnc-server-6-11-0-released-0-2"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-41975",
        "datePublished": "2022-09-30T17:20:33.000Z",
        "dateReserved": "2022-09-30T00:00:00.000Z",
        "dateUpdated": "2025-05-20T16:02:59.158Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-41380 (GCVE-0-2021-41380)

    Vulnerability from cvelistv5 – Published: 2021-09-17 19:14 – Updated: 2024-08-04 03:08 Disputed
    VLAI
    Summary
    RealVNC Viewer 6.21.406 allows remote VNC servers to cause a denial of service (application crash) via crafted RFB protocol data. NOTE: It is asserted that this issue requires social engineering a user into connecting to a fake VNC Server. The VNC Viewer application they are using will then hang, until terminated, but no memory leak occurs - the resources are freed once the hung process is terminated and the resource usage is constant during the hang. Only the process that is connected to the fake Server is affected. This is an application bug, not a security issue
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T03:08:32.392Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "RealVNC Viewer 6.21.406 allows remote VNC servers to cause a denial of service (application crash) via crafted RFB protocol data. NOTE: It is asserted that this issue requires social engineering a user into connecting to a fake VNC Server. The VNC Viewer application they are using will then hang, until terminated, but no memory leak occurs - the resources are freed once the hung process is terminated and the resource usage is constant during the hang. Only the process that is connected to the fake Server is affected. This is an application bug, not a security issue"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-24T15:34:47.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41380",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** RealVNC Viewer 6.21.406 allows remote VNC servers to cause a denial of service (application crash) via crafted RFB protocol data. NOTE: It is asserted that this issue requires social engineering a user into connecting to a fake VNC Server. The VNC Viewer application they are using will then hang, until terminated, but no memory leak occurs - the resources are freed once the hung process is terminated and the resource usage is constant during the hang. Only the process that is connected to the fake Server is affected. This is an application bug, not a security issue."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03",
                  "refsource": "MISC",
                  "url": "https://gist.github.com/totaam/a90f2bb40f5b693ccec0ae903d021b03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41380",
        "datePublished": "2021-09-17T19:14:44.000Z",
        "dateReserved": "2021-09-17T00:00:00.000Z",
        "dateUpdated": "2024-08-04T03:08:32.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }