Search criteria

6 vulnerabilities found for vmu-c_pv_firmware by carlosgavazzi

CVE-2017-5146 (GCVE-0-2017-5146)

Vulnerability from nvd – Published: 2017-02-13 21:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text.
Severity ?
No CVSS data available.
CWE
  • Carlo Gavazzi VMU-C EM and VMU-C PV clear-text storage
Assigner
References
Impacted products
Vendor Product Version
n/a Carlo Gavazzi VMU-C EM and VMU-C PV Affected: Carlo Gavazzi VMU-C EM and VMU-C PV
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:34.228Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "95411",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/95411"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Carlo Gavazzi VMU-C EM and VMU-C PV",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Carlo Gavazzi VMU-C EM and VMU-C PV"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Carlo Gavazzi VMU-C EM and VMU-C PV clear-text storage",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "95411",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/95411"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-5146",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Carlo Gavazzi VMU-C EM and VMU-C PV",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Carlo Gavazzi VMU-C EM and VMU-C PV"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Carlo Gavazzi VMU-C EM and VMU-C PV clear-text storage"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "95411",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/95411"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-5146",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2017-01-03T00:00:00",
    "dateUpdated": "2024-08-05T14:55:34.228Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5145 (GCVE-0-2017-5145)

Vulnerability from nvd – Published: 2017-02-13 21:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
Severity ?
No CVSS data available.
CWE
  • Carlo Gavazzi VMU-C EM and VMU-C PV csrf
Assigner
References
Impacted products
Vendor Product Version
n/a Carlo Gavazzi VMU-C EM and VMU-C PV Affected: Carlo Gavazzi VMU-C EM and VMU-C PV
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:34.927Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "95411",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/95411"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Carlo Gavazzi VMU-C EM and VMU-C PV",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Carlo Gavazzi VMU-C EM and VMU-C PV"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Carlo Gavazzi VMU-C EM and VMU-C PV csrf",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "95411",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/95411"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-5145",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Carlo Gavazzi VMU-C EM and VMU-C PV",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Carlo Gavazzi VMU-C EM and VMU-C PV"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Carlo Gavazzi VMU-C EM and VMU-C PV csrf"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "95411",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/95411"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-5145",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2017-01-03T00:00:00",
    "dateUpdated": "2024-08-05T14:55:34.927Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5144 (GCVE-0-2017-5144)

Vulnerability from nvd – Published: 2017-02-13 21:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.
Severity ?
No CVSS data available.
CWE
  • Carlo Gavazzi VMU-C EM and VMU-C PV access control flaw
Assigner
References
Impacted products
Vendor Product Version
n/a Carlo Gavazzi VMU-C EM and VMU-C PV Affected: Carlo Gavazzi VMU-C EM and VMU-C PV
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.374Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "95411",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/95411"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Carlo Gavazzi VMU-C EM and VMU-C PV",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Carlo Gavazzi VMU-C EM and VMU-C PV"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Carlo Gavazzi VMU-C EM and VMU-C PV access control flaw",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "95411",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/95411"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-5144",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Carlo Gavazzi VMU-C EM and VMU-C PV",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Carlo Gavazzi VMU-C EM and VMU-C PV"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Carlo Gavazzi VMU-C EM and VMU-C PV access control flaw"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "95411",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/95411"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-5144",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2017-01-03T00:00:00",
    "dateUpdated": "2024-08-05T14:55:35.374Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5144 (GCVE-0-2017-5144)

Vulnerability from cvelistv5 – Published: 2017-02-13 21:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.
Severity ?
No CVSS data available.
CWE
  • Carlo Gavazzi VMU-C EM and VMU-C PV access control flaw
Assigner
References
Impacted products
Vendor Product Version
n/a Carlo Gavazzi VMU-C EM and VMU-C PV Affected: Carlo Gavazzi VMU-C EM and VMU-C PV
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.374Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "95411",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/95411"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Carlo Gavazzi VMU-C EM and VMU-C PV",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Carlo Gavazzi VMU-C EM and VMU-C PV"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Carlo Gavazzi VMU-C EM and VMU-C PV access control flaw",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "95411",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/95411"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-5144",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Carlo Gavazzi VMU-C EM and VMU-C PV",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Carlo Gavazzi VMU-C EM and VMU-C PV"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Carlo Gavazzi VMU-C EM and VMU-C PV access control flaw"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "95411",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/95411"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-5144",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2017-01-03T00:00:00",
    "dateUpdated": "2024-08-05T14:55:35.374Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5145 (GCVE-0-2017-5145)

Vulnerability from cvelistv5 – Published: 2017-02-13 21:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
Severity ?
No CVSS data available.
CWE
  • Carlo Gavazzi VMU-C EM and VMU-C PV csrf
Assigner
References
Impacted products
Vendor Product Version
n/a Carlo Gavazzi VMU-C EM and VMU-C PV Affected: Carlo Gavazzi VMU-C EM and VMU-C PV
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:34.927Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "95411",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/95411"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Carlo Gavazzi VMU-C EM and VMU-C PV",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Carlo Gavazzi VMU-C EM and VMU-C PV"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Carlo Gavazzi VMU-C EM and VMU-C PV csrf",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "95411",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/95411"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-5145",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Carlo Gavazzi VMU-C EM and VMU-C PV",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Carlo Gavazzi VMU-C EM and VMU-C PV"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Carlo Gavazzi VMU-C EM and VMU-C PV csrf"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "95411",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/95411"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-5145",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2017-01-03T00:00:00",
    "dateUpdated": "2024-08-05T14:55:34.927Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5146 (GCVE-0-2017-5146)

Vulnerability from cvelistv5 – Published: 2017-02-13 21:00 – Updated: 2024-08-05 14:55
VLAI?
Summary
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text.
Severity ?
No CVSS data available.
CWE
  • Carlo Gavazzi VMU-C EM and VMU-C PV clear-text storage
Assigner
References
Impacted products
Vendor Product Version
n/a Carlo Gavazzi VMU-C EM and VMU-C PV Affected: Carlo Gavazzi VMU-C EM and VMU-C PV
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:34.228Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "95411",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/95411"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Carlo Gavazzi VMU-C EM and VMU-C PV",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Carlo Gavazzi VMU-C EM and VMU-C PV"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Carlo Gavazzi VMU-C EM and VMU-C PV clear-text storage",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "95411",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/95411"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-5146",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Carlo Gavazzi VMU-C EM and VMU-C PV",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Carlo Gavazzi VMU-C EM and VMU-C PV"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Carlo Gavazzi VMU-C EM and VMU-C PV clear-text storage"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "95411",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/95411"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-5146",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2017-01-03T00:00:00",
    "dateUpdated": "2024-08-05T14:55:34.228Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}