Search

Find a vulnerability

Search criteria

    14 vulnerabilities found for vigorconnect by draytek

    CVE-2021-20129 (GCVE-0-2021-20129)

    Vulnerability from nvd – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs.
    Severity
    No CVSS data available.
    CWE
    • Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.422Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:49:35.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20129",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Exposure of Sensitive Information to an Unauthorized Actor"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20129",
        "datePublished": "2021-10-13T15:49:35.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20128 (GCVE-0-2021-20128)

    Vulnerability from nvd – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized.
    Severity
    No CVSS data available.
    CWE
    • Cross-site Scripting
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.492Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-site Scripting",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:49:30.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20128",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site Scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20128",
        "datePublished": "2021-10-13T15:49:30.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.492Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20127 (GCVE-0-2021-20127)

    Vulnerability from nvd – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges.
    Severity
    No CVSS data available.
    CWE
    • Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.367Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Access Control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:49:25.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20127",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20127",
        "datePublished": "2021-10-13T15:49:25.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20126 (GCVE-0-2021-20126)

    Vulnerability from nvd – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
    Severity
    No CVSS data available.
    CWE
    • Cross-Site Request Forgery
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.598Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:48:15.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20126",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-Site Request Forgery"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20126",
        "datePublished": "2021-10-13T15:48:15.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.598Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20125 (GCVE-0-2021-20125)

    Vulnerability from nvd – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges.
    Severity
    No CVSS data available.
    CWE
    • Unrestricted Upload of File with Dangerous Type
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.504Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:48:08.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20125",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Unrestricted Upload of File with Dangerous Type"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20125",
        "datePublished": "2021-10-13T15:48:08.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.504Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20124 (GCVE-0-2021-20124)

    Vulnerability from nvd – Published: 2021-10-13 15:48 – Updated: 2025-10-21 23:25
    Summary
    A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Path Traversal
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    draytek vigorconnect Affected: 1.6.0
        cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.526Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vigorconnect",
                "vendor": "draytek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.6.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-20124",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-03T12:28:51.460379Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2024-09-03",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-22",
                    "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:28.553Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2024-09-03T00:00:00.000Z",
                "value": "CVE-2021-20124 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Path Traversal",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:48:03.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20124",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Path Traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20124",
        "datePublished": "2021-10-13T15:48:03.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:28.553Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20123 (GCVE-0-2021-20123)

    Vulnerability from nvd – Published: 2021-10-13 15:47 – Updated: 2025-10-21 23:25
    Summary
    A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Path Traversal
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    draytek vigorconnect Affected: 1.6.0
        cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.620Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vigorconnect",
                "vendor": "draytek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.6.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-20123",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-03T12:29:01.834786Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2024-09-03",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-22",
                    "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:28.693Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2024-09-03T00:00:00.000Z",
                "value": "CVE-2021-20123 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Path Traversal",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:47:58.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20123",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Path Traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20123",
        "datePublished": "2021-10-13T15:47:58.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:28.693Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20129 (GCVE-0-2021-20129)

    Vulnerability from cvelistv5 – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs.
    Severity
    No CVSS data available.
    CWE
    • Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.422Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:49:35.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20129",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Exposure of Sensitive Information to an Unauthorized Actor"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20129",
        "datePublished": "2021-10-13T15:49:35.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20128 (GCVE-0-2021-20128)

    Vulnerability from cvelistv5 – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized.
    Severity
    No CVSS data available.
    CWE
    • Cross-site Scripting
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.492Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-site Scripting",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:49:30.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20128",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site Scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20128",
        "datePublished": "2021-10-13T15:49:30.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.492Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20127 (GCVE-0-2021-20127)

    Vulnerability from cvelistv5 – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges.
    Severity
    No CVSS data available.
    CWE
    • Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.367Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Access Control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:49:25.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20127",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20127",
        "datePublished": "2021-10-13T15:49:25.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20126 (GCVE-0-2021-20126)

    Vulnerability from cvelistv5 – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
    Severity
    No CVSS data available.
    CWE
    • Cross-Site Request Forgery
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.598Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:48:15.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20126",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-Site Request Forgery"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20126",
        "datePublished": "2021-10-13T15:48:15.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.598Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20125 (GCVE-0-2021-20125)

    Vulnerability from cvelistv5 – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges.
    Severity
    No CVSS data available.
    CWE
    • Unrestricted Upload of File with Dangerous Type
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.504Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:48:08.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20125",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Unrestricted Upload of File with Dangerous Type"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20125",
        "datePublished": "2021-10-13T15:48:08.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.504Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20124 (GCVE-0-2021-20124)

    Vulnerability from cvelistv5 – Published: 2021-10-13 15:48 – Updated: 2025-10-21 23:25
    Summary
    A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Path Traversal
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    draytek vigorconnect Affected: 1.6.0
        cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.526Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vigorconnect",
                "vendor": "draytek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.6.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-20124",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-03T12:28:51.460379Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2024-09-03",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-22",
                    "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:28.553Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2024-09-03T00:00:00.000Z",
                "value": "CVE-2021-20124 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Path Traversal",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:48:03.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20124",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Path Traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20124",
        "datePublished": "2021-10-13T15:48:03.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:28.553Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20123 (GCVE-0-2021-20123)

    Vulnerability from cvelistv5 – Published: 2021-10-13 15:47 – Updated: 2025-10-21 23:25
    Summary
    A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Path Traversal
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Draytek VigorConnect Affected: 1.6.0-B3
    draytek vigorconnect Affected: 1.6.0
        cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.620Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2021-42"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vigorconnect",
                "vendor": "draytek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.6.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-20123",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-03T12:29:01.834786Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2024-09-03",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-22",
                    "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:28.693Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2024-09-03T00:00:00.000Z",
                "value": "CVE-2021-20123 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Draytek VigorConnect",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.6.0-B3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Path Traversal",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-13T15:47:58.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2021-42"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2021-20123",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Draytek VigorConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.6.0-B3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Path Traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2021-42",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2021-42"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2021-20123",
        "datePublished": "2021-10-13T15:47:58.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:28.693Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }