Search criteria
8 vulnerabilities found for video_streaming_gateway by bosch
CVE-2023-32230 (GCVE-0-2023-32230)
Vulnerability from nvd – Published: 2023-12-18 12:58 – Updated: 2024-08-02 15:10
VLAI?
Summary
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation.
Severity ?
7.5 (High)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
0 , ≤ 04.10.0079
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:10:24.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "04.10.0079",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.1.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.0.0.178",
"status": "affected",
"version": "9.0.0",
"versionType": "custom"
}
]
},
{
"product": "Monitorwall",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.00.0164",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7513",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7523",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:58:08.690Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-32230",
"datePublished": "2023-12-18T12:58:08.690Z",
"dateReserved": "2023-05-04T21:01:16.508Z",
"dateUpdated": "2024-08-02T15:10:24.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6790 (GCVE-0-2020-6790)
Vulnerability from nvd – Published: 2021-03-25 15:53 – Updated: 2024-09-17 04:25
VLAI?
Title
Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer
Summary
Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from.
Severity ?
7.8 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | Video Streaming Gateway |
Affected:
unspecified , ≤ 6.45.10
(custom)
|
Credits
Dhiraj Mishra
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:11:05.015Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "6.45.10",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dhiraj Mishra"
}
],
"datePublic": "2021-03-24T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-25T15:53:57",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "EXTERNAL"
},
"title": "Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-03-24",
"ID": "CVE-2020-6790",
"STATE": "PUBLIC",
"TITLE": "Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Video Streaming Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "6.45.10"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dhiraj Mishra"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2020-6790",
"datePublished": "2021-03-25T15:53:57.342668Z",
"dateReserved": "2020-01-10T00:00:00",
"dateUpdated": "2024-09-17T04:25:29.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6769 (GCVE-0-2020-6769)
Vulnerability from nvd – Published: 2020-02-07 19:57 – Updated: 2024-09-16 21:03
VLAI?
Title
Missing Authentication for Critical Function in Bosch Video Streaming Gateway
Summary
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
Severity ?
10 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | DIVAR IP 2000 |
Affected:
unspecified , ≤ 3.62.0019
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:11:04.658Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIVAR IP 2000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.62.0019",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.80.0039",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "6.45.08",
"status": "affected",
"version": "6.45",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.44.0030",
"status": "affected",
"version": "6.44",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.43.0023",
"status": "affected",
"version": "6.43",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.42.10",
"status": "affected",
"version": "6.42 and older",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 3000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"product": "DIVAR IP 7000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "All"
}
]
}
],
"datePublic": "2020-01-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-07T19:57:12",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
}
],
"source": {
"advisory": "BOSCH-SA-260625-BT",
"discovery": "INTERNAL"
},
"title": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2020-01-29T13:00:00.000Z",
"ID": "CVE-2020-6769",
"STATE": "PUBLIC",
"TITLE": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIVAR IP 2000",
"version": {
"version_data": [
{
"configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed",
"version_affected": "\u003c=",
"version_value": "3.62.0019"
}
]
}
},
{
"product_name": "DIVAR IP 5000",
"version": {
"version_data": [
{
"configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed",
"version_affected": "\u003c=",
"version_value": "3.80.0039"
}
]
}
},
{
"product_name": "Video Streaming Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "6.45",
"version_value": "6.45.08"
},
{
"version_affected": "\u003c=",
"version_name": "6.44",
"version_value": "6.44.0030"
},
{
"version_affected": "\u003c=",
"version_name": "6.43",
"version_value": "6.43.0023"
},
{
"version_affected": "\u003c=",
"version_name": "6.42 and older",
"version_value": "6.42.10"
}
]
}
},
{
"product_name": "DIVAR IP 3000",
"version": {
"version_data": [
{
"configuration": "vulnerable VSG version installed",
"version_affected": "=",
"version_value": "All"
}
]
}
},
{
"product_name": "DIVAR IP 7000",
"version": {
"version_data": [
{
"configuration": "vulnerable VSG version installed",
"version_affected": "=",
"version_value": "All"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 5000",
"version": {
"version_data": [
{
"configuration": "vulnerable VSG version installed",
"version_affected": "=",
"version_value": "All"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-260625-BT",
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2020-6769",
"datePublished": "2020-02-07T19:57:12.914579Z",
"dateReserved": "2020-01-10T00:00:00",
"dateUpdated": "2024-09-16T21:03:26.539Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from nvd – Published: 2019-05-29 18:55 – Updated: 2024-09-16 16:38
VLAI?
Title
Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-04-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:55:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-04-04T22:00:00.000Z",
"ID": "CVE-2019-6957",
"STATE": "PUBLIC",
"TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6957",
"datePublished": "2019-05-29T18:55:20.387906Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-16T16:38:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32230 (GCVE-0-2023-32230)
Vulnerability from cvelistv5 – Published: 2023-12-18 12:58 – Updated: 2024-08-02 15:10
VLAI?
Summary
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation.
Severity ?
7.5 (High)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
0 , ≤ 04.10.0079
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:10:24.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "04.10.0079",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.1.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.0.0.178",
"status": "affected",
"version": "9.0.0",
"versionType": "custom"
}
]
},
{
"product": "Monitorwall",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.00.0164",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7513",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7523",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:58:08.690Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-32230",
"datePublished": "2023-12-18T12:58:08.690Z",
"dateReserved": "2023-05-04T21:01:16.508Z",
"dateUpdated": "2024-08-02T15:10:24.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6790 (GCVE-0-2020-6790)
Vulnerability from cvelistv5 – Published: 2021-03-25 15:53 – Updated: 2024-09-17 04:25
VLAI?
Title
Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer
Summary
Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from.
Severity ?
7.8 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | Video Streaming Gateway |
Affected:
unspecified , ≤ 6.45.10
(custom)
|
Credits
Dhiraj Mishra
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:11:05.015Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "6.45.10",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dhiraj Mishra"
}
],
"datePublic": "2021-03-24T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-25T15:53:57",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "EXTERNAL"
},
"title": "Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-03-24",
"ID": "CVE-2020-6790",
"STATE": "PUBLIC",
"TITLE": "Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Video Streaming Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "6.45.10"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dhiraj Mishra"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2020-6790",
"datePublished": "2021-03-25T15:53:57.342668Z",
"dateReserved": "2020-01-10T00:00:00",
"dateUpdated": "2024-09-17T04:25:29.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6769 (GCVE-0-2020-6769)
Vulnerability from cvelistv5 – Published: 2020-02-07 19:57 – Updated: 2024-09-16 21:03
VLAI?
Title
Missing Authentication for Critical Function in Bosch Video Streaming Gateway
Summary
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
Severity ?
10 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | DIVAR IP 2000 |
Affected:
unspecified , ≤ 3.62.0019
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:11:04.658Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIVAR IP 2000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.62.0019",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.80.0039",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "6.45.08",
"status": "affected",
"version": "6.45",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.44.0030",
"status": "affected",
"version": "6.44",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.43.0023",
"status": "affected",
"version": "6.43",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.42.10",
"status": "affected",
"version": "6.42 and older",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 3000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"product": "DIVAR IP 7000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "All"
}
]
}
],
"datePublic": "2020-01-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-07T19:57:12",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
}
],
"source": {
"advisory": "BOSCH-SA-260625-BT",
"discovery": "INTERNAL"
},
"title": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2020-01-29T13:00:00.000Z",
"ID": "CVE-2020-6769",
"STATE": "PUBLIC",
"TITLE": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIVAR IP 2000",
"version": {
"version_data": [
{
"configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed",
"version_affected": "\u003c=",
"version_value": "3.62.0019"
}
]
}
},
{
"product_name": "DIVAR IP 5000",
"version": {
"version_data": [
{
"configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed",
"version_affected": "\u003c=",
"version_value": "3.80.0039"
}
]
}
},
{
"product_name": "Video Streaming Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "6.45",
"version_value": "6.45.08"
},
{
"version_affected": "\u003c=",
"version_name": "6.44",
"version_value": "6.44.0030"
},
{
"version_affected": "\u003c=",
"version_name": "6.43",
"version_value": "6.43.0023"
},
{
"version_affected": "\u003c=",
"version_name": "6.42 and older",
"version_value": "6.42.10"
}
]
}
},
{
"product_name": "DIVAR IP 3000",
"version": {
"version_data": [
{
"configuration": "vulnerable VSG version installed",
"version_affected": "=",
"version_value": "All"
}
]
}
},
{
"product_name": "DIVAR IP 7000",
"version": {
"version_data": [
{
"configuration": "vulnerable VSG version installed",
"version_affected": "=",
"version_value": "All"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 5000",
"version": {
"version_data": [
{
"configuration": "vulnerable VSG version installed",
"version_affected": "=",
"version_value": "All"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-260625-BT",
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2020-6769",
"datePublished": "2020-02-07T19:57:12.914579Z",
"dateReserved": "2020-01-10T00:00:00",
"dateUpdated": "2024-09-16T21:03:26.539Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from cvelistv5 – Published: 2019-05-29 18:55 – Updated: 2024-09-16 16:38
VLAI?
Title
Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-04-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:55:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-04-04T22:00:00.000Z",
"ID": "CVE-2019-6957",
"STATE": "PUBLIC",
"TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6957",
"datePublished": "2019-05-29T18:55:20.387906Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-16T16:38:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}