Search
Find a vulnerability
Search criteria
21 vulnerabilities found for v1600d4l_firmware by vsolcn
FKIE_CVE-2020-29383
Vulnerability from fkie_nvd - Published: 2020-11-29 01:15 - Updated: 2026-06-17 03:11
Severity
Summary
An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vsolcn | v1600d4l_firmware | 1.01.49 | |
| vsolcn | v1600d4l | - | |
| vsolcn | v1600d-mini_firmware | 1.01.48 | |
| vsolcn | v1600d-mini | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d4l_firmware:1.01.49:*:*:*:*:*:*:*",
"matchCriteriaId": "6441837A-B3BA-4CB6-8507-40D089DC82BA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d4l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4991AB-71EA-4DF1-8142-E13985017197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d-mini_firmware:1.01.48:*:*:*:*:*:*:*",
"matchCriteriaId": "C40945D6-0A82-4EF6-8665-E177184874DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d-mini:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8407505-E9A3-4435-A8CC-70BD24245516",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos OLT V-SOL V1600D4L versi\u00f3n V1.01.49 y V1600D-MINI versi\u00f3n V1.01.48.\u0026#xa0;Una clave privada RSA embebida (espec\u00edfica para V1600D4L y V1600D-MINI) est\u00e1 contenida en las imagenes del firmware"
}
],
"id": "CVE-2020-29383",
"lastModified": "2026-06-17T03:11:15.210",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-29T01:15:11.317",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-29381
Vulnerability from fkie_nvd - Published: 2020-11-29 01:15 - Updated: 2026-06-17 03:11
Severity
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in "upload tftp syslog" and "upload tftp configuration" in the CLI via a crafted filename.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vsolcn | v1600d_firmware | 2.03.57 | |
| vsolcn | v1600d_firmware | 2.03.69 | |
| vsolcn | v1600d | - | |
| vsolcn | v1600d4l_firmware | 1.01.49 | |
| vsolcn | v1600d4l | - | |
| vsolcn | v1600d-mini_firmware | 1.01.48 | |
| vsolcn | v1600d-mini | - | |
| vsolcn | v1600g1_firmware | 1.9.7 | |
| vsolcn | v1600g1_firmware | 2.0.7 | |
| vsolcn | v1600g1 | - | |
| vsolcn | v1600g2_firmware | 1.1.4 | |
| vsolcn | v1600g2 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.57:*:*:*:*:*:*:*",
"matchCriteriaId": "9E209E77-9032-445E-8537-63D84ABB3E94",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.69:*:*:*:*:*:*:*",
"matchCriteriaId": "8CF8489F-58DC-4A4D-B19B-D31FD65356EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D6A406A6-DEBA-4715-9F9B-21D3FA94FCED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d4l_firmware:1.01.49:*:*:*:*:*:*:*",
"matchCriteriaId": "6441837A-B3BA-4CB6-8507-40D089DC82BA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d4l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4991AB-71EA-4DF1-8142-E13985017197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d-mini_firmware:1.01.48:*:*:*:*:*:*:*",
"matchCriteriaId": "C40945D6-0A82-4EF6-8665-E177184874DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d-mini:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8407505-E9A3-4435-A8CC-70BD24245516",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:1.9.7:*:*:*:*:*:*:*",
"matchCriteriaId": "5BDA94F4-CEBF-4CC3-8799-C2C6424A7127",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:2.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "0D5E0E91-7C0C-4696-9E8C-269D872B9E2A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "351D7DCA-129F-417A-822F-7FA2A2D6CE83",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g2_firmware:1.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "03765CFC-6994-41B0-9650-DD1EB2C5A886",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5892BFA9-5870-4C42-AD71-7984C975ABDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in \"upload tftp syslog\" and \"upload tftp configuration\" in the CLI via a crafted filename."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos OLT V-SOL V1600D versiones V2.03.69 y V2.03.57, V1600D4L versi\u00f3n V1.01.49, V1600D-MINI versi\u00f3n V1.01.48, V1600G1 versiones V2.0.7 y V1.9.7, y V1600G2 versi\u00f3n V1.1.4.\u0026#xa0;Una inyecci\u00f3n de comandos puede ocurrir en \"upload tftp syslog\" y \"upload tftp configuration\" en la CLI por medio de un nombre de archivo dise\u00f1ado"
}
],
"id": "CVE-2020-29381",
"lastModified": "2026-06-17T03:11:14.987",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-29T01:15:11.193",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-29380
Vulnerability from fkie_nvd - Published: 2020-11-29 01:15 - Updated: 2026-06-17 03:11
Severity
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vsolcn | v1600d_firmware | 2.03.57 | |
| vsolcn | v1600d_firmware | 2.03.69 | |
| vsolcn | v1600d | - | |
| vsolcn | v1600d4l_firmware | 1.01.49 | |
| vsolcn | v1600d4l | - | |
| vsolcn | v1600d-mini_firmware | 1.01.48 | |
| vsolcn | v1600d-mini | - | |
| vsolcn | v1600g1_firmware | 1.9.7 | |
| vsolcn | v1600g1_firmware | 2.0.7 | |
| vsolcn | v1600g1 | - | |
| vsolcn | v1600g2_firmware | 1.1.4 | |
| vsolcn | v1600g2 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.57:*:*:*:*:*:*:*",
"matchCriteriaId": "9E209E77-9032-445E-8537-63D84ABB3E94",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.69:*:*:*:*:*:*:*",
"matchCriteriaId": "8CF8489F-58DC-4A4D-B19B-D31FD65356EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D6A406A6-DEBA-4715-9F9B-21D3FA94FCED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d4l_firmware:1.01.49:*:*:*:*:*:*:*",
"matchCriteriaId": "6441837A-B3BA-4CB6-8507-40D089DC82BA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d4l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4991AB-71EA-4DF1-8142-E13985017197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d-mini_firmware:1.01.48:*:*:*:*:*:*:*",
"matchCriteriaId": "C40945D6-0A82-4EF6-8665-E177184874DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d-mini:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8407505-E9A3-4435-A8CC-70BD24245516",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:1.9.7:*:*:*:*:*:*:*",
"matchCriteriaId": "5BDA94F4-CEBF-4CC3-8799-C2C6424A7127",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:2.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "0D5E0E91-7C0C-4696-9E8C-269D872B9E2A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "351D7DCA-129F-417A-822F-7FA2A2D6CE83",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g2_firmware:1.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "03765CFC-6994-41B0-9650-DD1EB2C5A886",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5892BFA9-5870-4C42-AD71-7984C975ABDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos OLT V-SOL V1600D versiones V2.03.69 y V2.03.57, V1600D4L versi\u00f3n V1.01.49, V1600D-MINI versi\u00f3n V1.01.48, V1600G1 versiones V2.0.7 y V1.9.7, y V1600G2 versi\u00f3n V1.1.4.\u0026#xa0;TELNET es ofrecido por defecto, pero SSH no siempre est\u00e1 disponible.\u0026#xa0;Un atacante puede interceptar contrase\u00f1as enviadas en texto plano y conducir un ataque de tipo man-in-the-middle en la administraci\u00f3n del dispositivo"
}
],
"id": "CVE-2020-29380",
"lastModified": "2026-06-17T03:11:14.870",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-29T01:15:11.147",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
},
{
"lang": "en",
"value": "CWE-522"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-29379
Vulnerability from fkie_nvd - Published: 2020-11-29 01:15 - Updated: 2026-06-17 03:11
Severity
Summary
An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://seclists.org/fulldisclosure/2020/Jul/14 | Exploit, Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2020/Jul/14 | Exploit, Mailing List, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vsolcn | v1600d4l_firmware | 1.01.49 | |
| vsolcn | v1600d4l | - | |
| vsolcn | v1600d-mini_firmware | 1.01.48 | |
| vsolcn | v1600d-mini | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d4l_firmware:1.01.49:*:*:*:*:*:*:*",
"matchCriteriaId": "6441837A-B3BA-4CB6-8507-40D089DC82BA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d4l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4991AB-71EA-4DF1-8142-E13985017197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d-mini_firmware:1.01.48:*:*:*:*:*:*:*",
"matchCriteriaId": "C40945D6-0A82-4EF6-8665-E177184874DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d-mini:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8407505-E9A3-4435-A8CC-70BD24245516",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos OLT V-SOL V1600D4L versi\u00f3n V1.01.49 y V1600D-MINI versi\u00f3n V1.01.48.\u0026#xa0;Durante el proceso de actualizaci\u00f3n del firmware, el script de actualizaci\u00f3n inicia un proceso telnetd -l /bin/sh que no requiere autenticaci\u00f3n para el acceso TELNET"
}
],
"id": "CVE-2020-29379",
"lastModified": "2026-06-17T03:11:14.763",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-29T01:15:11.083",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-29378
Vulnerability from fkie_nvd - Published: 2020-11-29 01:15 - Updated: 2026-06-17 03:11
Severity
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vsolcn | v1600d_firmware | 2.03.57 | |
| vsolcn | v1600d_firmware | 2.03.69 | |
| vsolcn | v1600d | - | |
| vsolcn | v1600d4l_firmware | 1.01.49 | |
| vsolcn | v1600d4l | - | |
| vsolcn | v1600d-mini_firmware | 1.01.48 | |
| vsolcn | v1600d-mini | - | |
| vsolcn | v1600g1_firmware | 1.9.7 | |
| vsolcn | v1600g1_firmware | 2.0.7 | |
| vsolcn | v1600g1 | - | |
| vsolcn | v1600g2_firmware | 1.1.4 | |
| vsolcn | v1600g2 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.57:*:*:*:*:*:*:*",
"matchCriteriaId": "9E209E77-9032-445E-8537-63D84ABB3E94",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.69:*:*:*:*:*:*:*",
"matchCriteriaId": "8CF8489F-58DC-4A4D-B19B-D31FD65356EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D6A406A6-DEBA-4715-9F9B-21D3FA94FCED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d4l_firmware:1.01.49:*:*:*:*:*:*:*",
"matchCriteriaId": "6441837A-B3BA-4CB6-8507-40D089DC82BA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d4l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4991AB-71EA-4DF1-8142-E13985017197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d-mini_firmware:1.01.48:*:*:*:*:*:*:*",
"matchCriteriaId": "C40945D6-0A82-4EF6-8665-E177184874DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d-mini:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8407505-E9A3-4435-A8CC-70BD24245516",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:1.9.7:*:*:*:*:*:*:*",
"matchCriteriaId": "5BDA94F4-CEBF-4CC3-8799-C2C6424A7127",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:2.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "0D5E0E91-7C0C-4696-9E8C-269D872B9E2A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "351D7DCA-129F-417A-822F-7FA2A2D6CE83",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g2_firmware:1.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "03765CFC-6994-41B0-9650-DD1EB2C5A886",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5892BFA9-5870-4C42-AD71-7984C975ABDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos OLT V-SOL V1600D versiones V2.03.69 y V2.03.57, V1600D4L versi\u00f3n V1.01.49, V1600D-MINI versi\u00f3n V1.01.48, V1600G1 versiones V2.0.7 y V1.9.7, y V1600G2 versi\u00f3n V1.1.4.\u0026#xa0;Es posible elevar el privilegio de un usuario de la CLI (para acceso administrativo completo) mediante el uso de la contrase\u00f1a !j@l#y$z%x6x7q8c9z) para el comando habilitado"
}
],
"id": "CVE-2020-29378",
"lastModified": "2026-06-17T03:11:14.650",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-29T01:15:11.020",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-29376
Vulnerability from fkie_nvd - Published: 2020-11-29 01:15 - Updated: 2026-06-17 03:11
Severity
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://seclists.org/fulldisclosure/2020/Jul/14 | Exploit, Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2020/Jul/14 | Exploit, Mailing List, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vsolcn | v1600d_firmware | 2.03.57 | |
| vsolcn | v1600d_firmware | 2.03.69 | |
| vsolcn | v1600d | - | |
| vsolcn | v1600d4l_firmware | 1.01.49 | |
| vsolcn | v1600d4l | - | |
| vsolcn | v1600d-mini_firmware | 1.01.48 | |
| vsolcn | v1600d-mini | - | |
| vsolcn | v1600g1_firmware | 1.9.7 | |
| vsolcn | v1600g1_firmware | 2.0.7 | |
| vsolcn | v1600g1 | - | |
| vsolcn | v1600g2_firmware | 1.1.4 | |
| vsolcn | v1600g2 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.57:*:*:*:*:*:*:*",
"matchCriteriaId": "9E209E77-9032-445E-8537-63D84ABB3E94",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.69:*:*:*:*:*:*:*",
"matchCriteriaId": "8CF8489F-58DC-4A4D-B19B-D31FD65356EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D6A406A6-DEBA-4715-9F9B-21D3FA94FCED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d4l_firmware:1.01.49:*:*:*:*:*:*:*",
"matchCriteriaId": "6441837A-B3BA-4CB6-8507-40D089DC82BA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d4l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4991AB-71EA-4DF1-8142-E13985017197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d-mini_firmware:1.01.48:*:*:*:*:*:*:*",
"matchCriteriaId": "C40945D6-0A82-4EF6-8665-E177184874DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d-mini:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8407505-E9A3-4435-A8CC-70BD24245516",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:1.9.7:*:*:*:*:*:*:*",
"matchCriteriaId": "5BDA94F4-CEBF-4CC3-8799-C2C6424A7127",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:2.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "0D5E0E91-7C0C-4696-9E8C-269D872B9E2A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "351D7DCA-129F-417A-822F-7FA2A2D6CE83",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g2_firmware:1.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "03765CFC-6994-41B0-9650-DD1EB2C5A886",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5892BFA9-5870-4C42-AD71-7984C975ABDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos OLT V-SOL V1600D versiones V2.03.69 y V2.03.57, V1600D4L versi\u00f3n V1.01.49, V1600D-MINI versi\u00f3n V1.01.48, V1600G1 versiones V2.0.7 y V1.9.7, y V1600G2 versi\u00f3n V1.1.4.\u0026#xa0;Se presenta una contrase\u00f1a !j@l#y$z%x6x7q8c9z) para que la cuenta de administrador se autentique en el servicio TELNET"
}
],
"id": "CVE-2020-29376",
"lastModified": "2026-06-17T03:11:14.430",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-29T01:15:10.630",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-29375
Vulnerability from fkie_nvd - Published: 2020-11-29 01:15 - Updated: 2026-06-17 03:11
Severity
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2020/Jul/14 | Mailing List, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vsolcn | v1600d_firmware | 2.03.57 | |
| vsolcn | v1600d_firmware | 2.03.69 | |
| vsolcn | v1600d | - | |
| vsolcn | v1600d4l_firmware | 1.01.49 | |
| vsolcn | v1600d4l | - | |
| vsolcn | v1600d-mini_firmware | 1.01.48 | |
| vsolcn | v1600d-mini | - | |
| vsolcn | v1600g1_firmware | 1.9.7 | |
| vsolcn | v1600g1_firmware | 2.0.7 | |
| vsolcn | v1600g1 | - | |
| vsolcn | v1600g2_firmware | 1.1.4 | |
| vsolcn | v1600g2 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.57:*:*:*:*:*:*:*",
"matchCriteriaId": "9E209E77-9032-445E-8537-63D84ABB3E94",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600d_firmware:2.03.69:*:*:*:*:*:*:*",
"matchCriteriaId": "8CF8489F-58DC-4A4D-B19B-D31FD65356EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D6A406A6-DEBA-4715-9F9B-21D3FA94FCED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d4l_firmware:1.01.49:*:*:*:*:*:*:*",
"matchCriteriaId": "6441837A-B3BA-4CB6-8507-40D089DC82BA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d4l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4991AB-71EA-4DF1-8142-E13985017197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600d-mini_firmware:1.01.48:*:*:*:*:*:*:*",
"matchCriteriaId": "C40945D6-0A82-4EF6-8665-E177184874DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600d-mini:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8407505-E9A3-4435-A8CC-70BD24245516",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:1.9.7:*:*:*:*:*:*:*",
"matchCriteriaId": "5BDA94F4-CEBF-4CC3-8799-C2C6424A7127",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:vsolcn:v1600g1_firmware:2.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "0D5E0E91-7C0C-4696-9E8C-269D872B9E2A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "351D7DCA-129F-417A-822F-7FA2A2D6CE83",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:vsolcn:v1600g2_firmware:1.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "03765CFC-6994-41B0-9650-DD1EB2C5A886",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:vsolcn:v1600g2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5892BFA9-5870-4C42-AD71-7984C975ABDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos OLT V-SOL V1600D versiones V2.03.69 y V2.03.57, V1600D4L versi\u00f3n V1.01.49, V1600D-MINI versi\u00f3n V1.01.48, V1600G1 versiones V2.0.7 y V1.9.7, y V1600G2 versi\u00f3n V1.1.4. Un atacante poco privilegiado (no administrador) puede usar una contrase\u00f1a embebida (4ef9cea10b2362f15ba4558b1d5c081f) para crear un usuario administrador"
}
],
"id": "CVE-2020-29375",
"lastModified": "2026-06-17T03:11:14.317",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-29T01:15:10.567",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-29383 (GCVE-0-2020-29383)
Vulnerability from nvd – Published: 2020-11-29 00:45 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:10.050Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:45:55.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29383",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29383",
"datePublished": "2020-11-29T00:45:55.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:10.050Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29381 (GCVE-0-2020-29381)
Vulnerability from nvd – Published: 2020-11-29 00:46 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in "upload tftp syslog" and "upload tftp configuration" in the CLI via a crafted filename.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:09.254Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in \"upload tftp syslog\" and \"upload tftp configuration\" in the CLI via a crafted filename."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:46:24.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29381",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in \"upload tftp syslog\" and \"upload tftp configuration\" in the CLI via a crafted filename."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29381",
"datePublished": "2020-11-29T00:46:24.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:09.254Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29380 (GCVE-0-2020-29380)
Vulnerability from nvd – Published: 2020-11-29 00:46 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:10.445Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:46:34.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29380",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29380",
"datePublished": "2020-11-29T00:46:34.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:10.445Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29379 (GCVE-0-2020-29379)
Vulnerability from nvd – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:09.239Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:12.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29379",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29379",
"datePublished": "2020-11-29T00:47:12.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:09.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29378 (GCVE-0-2020-29378)
Vulnerability from nvd – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:48
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:21.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29378",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29378",
"datePublished": "2020-11-29T00:47:21.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.934Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29376 (GCVE-0-2020-29376)
Vulnerability from nvd – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:48
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.696Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:39.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29376",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29376",
"datePublished": "2020-11-29T00:47:39.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.696Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29375 (GCVE-0-2020-29375)
Vulnerability from nvd – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:48
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.982Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:49.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29375",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29375",
"datePublished": "2020-11-29T00:47:49.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.982Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29375 (GCVE-0-2020-29375)
Vulnerability from cvelistv5 – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:48
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.982Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:49.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29375",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an admin user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29375",
"datePublished": "2020-11-29T00:47:49.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.982Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29376 (GCVE-0-2020-29376)
Vulnerability from cvelistv5 – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:48
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.696Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:39.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29376",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29376",
"datePublished": "2020-11-29T00:47:39.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.696Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29378 (GCVE-0-2020-29378)
Vulnerability from cvelistv5 – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:48
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:21.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29378",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. It is possible to elevate the privilege of a CLI user (to full administrative access) by using the password !j@l#y$z%x6x7q8c9z) for the enable command."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29378",
"datePublished": "2020-11-29T00:47:21.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.934Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29379 (GCVE-0-2020-29379)
Vulnerability from cvelistv5 – Published: 2020-11-29 00:47 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:09.239Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:47:12.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29379",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. During the process of updating the firmware, the update script starts a telnetd -l /bin/sh process that does not require authentication for TELNET access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29379",
"datePublished": "2020-11-29T00:47:12.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:09.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29380 (GCVE-0-2020-29380)
Vulnerability from cvelistv5 – Published: 2020-11-29 00:46 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:10.445Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:46:34.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29380",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29380",
"datePublished": "2020-11-29T00:46:34.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:10.445Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29381 (GCVE-0-2020-29381)
Vulnerability from cvelistv5 – Published: 2020-11-29 00:46 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in "upload tftp syslog" and "upload tftp configuration" in the CLI via a crafted filename.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:09.254Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in \"upload tftp syslog\" and \"upload tftp configuration\" in the CLI via a crafted filename."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:46:24.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29381",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in \"upload tftp syslog\" and \"upload tftp configuration\" in the CLI via a crafted filename."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29381",
"datePublished": "2020-11-29T00:46:24.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:09.254Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29383 (GCVE-0-2020-29383)
Vulnerability from cvelistv5 – Published: 2020-11-29 00:45 – Updated: 2024-08-04 16:55
VLAI
EPSS
VEX
Summary
An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://seclists.org/fulldisclosure/2020/Jul/14 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:55:10.050Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-29T00:45:55.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-29383",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on V-SOL V1600D4L V1.01.49 and V1600D-MINI V1.01.48 OLT devices. A hardcoded RSA private key (specific to V1600D4L and V1600D-MINI) is contained in the firmware images."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://seclists.org/fulldisclosure/2020/Jul/14",
"refsource": "MISC",
"url": "https://seclists.org/fulldisclosure/2020/Jul/14"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-29383",
"datePublished": "2020-11-29T00:45:55.000Z",
"dateReserved": "2020-11-29T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:55:10.050Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}