CVE-2024-42028 (GCVE-0-2024-42028)
Vulnerability from nvd – Published: 2024-10-28 15:54 – Updated: 2024-10-28 18:53
VLAI
EPSS
VEX
Summary
A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-28 18:53 UTC
CWE
- CWE-276 - Incorrect Default Permissions
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.4.62 , ≤ 8.4.62
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 8.4.62
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "8.4.62",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-42028",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-28T18:53:01.066571Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T18:53:11.285Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThanOrEqual": "8.4.62",
"status": "affected",
"version": "8.4.62",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T15:54:15.384Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-043-043/28e45c75-314e-4f07-a4f3-d17f67bd53f7"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-42028",
"datePublished": "2024-10-28T15:54:15.384Z",
"dateReserved": "2024-07-27T01:04:08.014Z",
"dateUpdated": "2024-10-28T18:53:11.285Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-42025 (GCVE-0-2024-42025)
Vulnerability from nvd – Published: 2024-09-13 15:47 – Updated: 2024-09-28 17:44
VLAI
EPSS
VEX
Summary
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-13 16:23 UTC
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.4.59 , < 8.4.59
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 8.3.32
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "8.3.32",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-42025",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-13T16:23:49.335442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-28T17:44:02.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "8.4.59",
"status": "affected",
"version": "8.4.59",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T15:47:19.568Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-042-042/c4f68b56-cdc4-4128-b2cb-5870209d1704"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-42025",
"datePublished": "2024-09-13T15:47:19.568Z",
"dateReserved": "2024-07-27T01:04:08.013Z",
"dateUpdated": "2024-09-28T17:44:02.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-27981 (GCVE-0-2024-27981)
Vulnerability from nvd – Published: 2024-04-04 22:16 – Updated: 2025-03-18 20:10
VLAI
EPSS
VEX
Summary
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.0.28 and earlier) allows a malicious actor with UniFi Network Application Administrator credentials to escalate privileges to root on the host device.
Affected Products:
UniFi Network Application (Version 8.0.28 and earlier) .
Mitigation:
Update UniFi Network Application to Version 8.1.113 or later.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-08 15:00 UTC
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.1.113 , < 8.1.113
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , < 8.1.113
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThan": "8.1.113",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-27981",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-08T15:00:54.373621Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T20:10:28.730Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:41:56.017Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-038-038/9d13fead-47de-4372-b2c1-745b8d6b0399"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "8.1.113",
"status": "affected",
"version": "8.1.113",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.0.28 and earlier) allows a malicious actor with UniFi Network Application Administrator credentials to escalate privileges to root on the host device.\r\n\r\nAffected Products:\r\nUniFi Network Application (Version 8.0.28 and earlier) .\r\n \r\nMitigation:\r\nUpdate UniFi Network Application to Version 8.1.113 or later."
}
],
"providerMetadata": {
"dateUpdated": "2024-04-04T22:16:29.361Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-038-038/9d13fead-47de-4372-b2c1-745b8d6b0399"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-27981",
"datePublished": "2024-04-04T22:16:29.361Z",
"dateReserved": "2024-02-29T01:04:06.640Z",
"dateUpdated": "2025-03-18T20:10:28.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41721 (GCVE-0-2023-41721)
Vulnerability from nvd – Published: 2023-10-25 00:24 – Updated: 2024-09-13 16:28
VLAI
EPSS
VEX
Summary
Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.
Affected Products:
UDM
UDM-PRO
UDM-SE
UDR
UDW
Mitigation:
Update UniFi Network to Version 7.5.187 or later.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 20:25 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti | UniFi Network Application |
Affected:
7.5.176 , ≤ 7.5.176
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.5.176
(custom)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:01:35.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41721",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T20:25:31.300359Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T16:28:08.626Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "7.5.176",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.\n\nAffected Products:\nUDM\nUDM-PRO\nUDM-SE\nUDR\nUDW\n \nMitigation:\nUpdate UniFi Network to Version 7.5.187 or later.\n"
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T00:24:34.072Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-41721",
"datePublished": "2023-10-25T00:24:34.072Z",
"dateReserved": "2023-08-31T01:00:11.771Z",
"dateUpdated": "2024-09-13T16:28:08.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28365 (GCVE-0-2023-28365)
Vulnerability from nvd – Published: 2023-06-30 23:40 – Updated: 2024-11-27 17:23
VLAI
EPSS
VEX
Summary
A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-27 17:22 UTC
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc. | UniFi Network application |
Affected:
7.3.83 , ≤ 7.3.83
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.3.83
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:38:25.371Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T17:22:20.390330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T17:23:23.036Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network application",
"vendor": "Ubiquiti Inc.",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "7.3.83",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-30T23:40:13.388Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-28365",
"datePublished": "2023-06-30T23:40:13.388Z",
"dateReserved": "2023-03-15T01:00:13.221Z",
"dateUpdated": "2024-11-27T17:23:23.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-42028 (GCVE-0-2024-42028)
Vulnerability from cvelistv5 – Published: 2024-10-28 15:54 – Updated: 2024-10-28 18:53
VLAI
EPSS
VEX
Summary
A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-28 18:53 UTC
CWE
- CWE-276 - Incorrect Default Permissions
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.4.62 , ≤ 8.4.62
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 8.4.62
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "8.4.62",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-42028",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-28T18:53:01.066571Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T18:53:11.285Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThanOrEqual": "8.4.62",
"status": "affected",
"version": "8.4.62",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T15:54:15.384Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-043-043/28e45c75-314e-4f07-a4f3-d17f67bd53f7"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-42028",
"datePublished": "2024-10-28T15:54:15.384Z",
"dateReserved": "2024-07-27T01:04:08.014Z",
"dateUpdated": "2024-10-28T18:53:11.285Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-42025 (GCVE-0-2024-42025)
Vulnerability from cvelistv5 – Published: 2024-09-13 15:47 – Updated: 2024-09-28 17:44
VLAI
EPSS
VEX
Summary
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-13 16:23 UTC
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.4.59 , < 8.4.59
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 8.3.32
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "8.3.32",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-42025",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-13T16:23:49.335442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-28T17:44:02.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "8.4.59",
"status": "affected",
"version": "8.4.59",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T15:47:19.568Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-042-042/c4f68b56-cdc4-4128-b2cb-5870209d1704"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-42025",
"datePublished": "2024-09-13T15:47:19.568Z",
"dateReserved": "2024-07-27T01:04:08.013Z",
"dateUpdated": "2024-09-28T17:44:02.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-27981 (GCVE-0-2024-27981)
Vulnerability from cvelistv5 – Published: 2024-04-04 22:16 – Updated: 2025-03-18 20:10
VLAI
EPSS
VEX
Summary
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.0.28 and earlier) allows a malicious actor with UniFi Network Application Administrator credentials to escalate privileges to root on the host device.
Affected Products:
UniFi Network Application (Version 8.0.28 and earlier) .
Mitigation:
Update UniFi Network Application to Version 8.1.113 or later.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-08 15:00 UTC
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.1.113 , < 8.1.113
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , < 8.1.113
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThan": "8.1.113",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-27981",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-08T15:00:54.373621Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T20:10:28.730Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:41:56.017Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-038-038/9d13fead-47de-4372-b2c1-745b8d6b0399"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "8.1.113",
"status": "affected",
"version": "8.1.113",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.0.28 and earlier) allows a malicious actor with UniFi Network Application Administrator credentials to escalate privileges to root on the host device.\r\n\r\nAffected Products:\r\nUniFi Network Application (Version 8.0.28 and earlier) .\r\n \r\nMitigation:\r\nUpdate UniFi Network Application to Version 8.1.113 or later."
}
],
"providerMetadata": {
"dateUpdated": "2024-04-04T22:16:29.361Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-038-038/9d13fead-47de-4372-b2c1-745b8d6b0399"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-27981",
"datePublished": "2024-04-04T22:16:29.361Z",
"dateReserved": "2024-02-29T01:04:06.640Z",
"dateUpdated": "2025-03-18T20:10:28.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41721 (GCVE-0-2023-41721)
Vulnerability from cvelistv5 – Published: 2023-10-25 00:24 – Updated: 2024-09-13 16:28
VLAI
EPSS
VEX
Summary
Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.
Affected Products:
UDM
UDM-PRO
UDM-SE
UDR
UDW
Mitigation:
Update UniFi Network to Version 7.5.187 or later.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 20:25 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti | UniFi Network Application |
Affected:
7.5.176 , ≤ 7.5.176
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.5.176
(custom)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:01:35.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41721",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T20:25:31.300359Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T16:28:08.626Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "7.5.176",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.\n\nAffected Products:\nUDM\nUDM-PRO\nUDM-SE\nUDR\nUDW\n \nMitigation:\nUpdate UniFi Network to Version 7.5.187 or later.\n"
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T00:24:34.072Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-41721",
"datePublished": "2023-10-25T00:24:34.072Z",
"dateReserved": "2023-08-31T01:00:11.771Z",
"dateUpdated": "2024-09-13T16:28:08.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28365 (GCVE-0-2023-28365)
Vulnerability from cvelistv5 – Published: 2023-06-30 23:40 – Updated: 2024-11-27 17:23
VLAI
EPSS
VEX
Summary
A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-27 17:22 UTC
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc. | UniFi Network application |
Affected:
7.3.83 , ≤ 7.3.83
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.3.83
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:38:25.371Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T17:22:20.390330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T17:23:23.036Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network application",
"vendor": "Ubiquiti Inc.",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "7.3.83",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-30T23:40:13.388Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-28365",
"datePublished": "2023-06-30T23:40:13.388Z",
"dateReserved": "2023-03-15T01:00:13.221Z",
"dateUpdated": "2024-11-27T17:23:23.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}