CVE-2020-7477 (GCVE-0-2020-7477)
Vulnerability from nvd – Published: 2020-03-23 19:14 – Updated: 2026-05-28 20:19
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet – 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions) |
Affected:
Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet – 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:18.651Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7477",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T20:19:17.040046Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T20:19:32.265Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:14:31.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7477",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)",
"version": {
"version_data": [
{
"version_value": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7477",
"datePublished": "2020-03-23T19:14:31.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-28T20:19:32.265Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6857 (GCVE-0-2019-6857)
Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:41
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) |
Affected:
Modicon M580
Affected: Modicon M340 Affected: Modicon Quantum Affected: Modicon Premium (see security notification for specific versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.438Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6857",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:39:16.673211Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:41:14.779Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M580"
},
{
"status": "affected",
"version": "Modicon M340"
},
{
"status": "affected",
"version": "Modicon Quantum"
},
{
"status": "affected",
"version": "Modicon Premium (see security notification for specific versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-21T23:03:43.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6857",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M580"
},
{
"version_value": "Modicon M340"
},
{
"version_value": "Modicon Quantum"
},
{
"version_value": "Modicon Premium (see security notification for specific versions)"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6857",
"datePublished": "2020-01-06T22:57:05.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:41:14.779Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6856 (GCVE-0-2019-6856)
Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:37
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) |
Affected:
Modicon M580
Affected: Modicon M340 Affected: Modicon Quantum Affected: Modicon Premium (see security notification for specific versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.415Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6856",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:36:59.205058Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:37:57.750Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M580"
},
{
"status": "affected",
"version": "Modicon M340"
},
{
"status": "affected",
"version": "Modicon Quantum"
},
{
"status": "affected",
"version": "Modicon Premium (see security notification for specific versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-21T23:04:36.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6856",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M580"
},
{
"version_value": "Modicon M340"
},
{
"version_value": "Modicon Quantum"
},
{
"version_value": "Modicon Premium (see security notification for specific versions)"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6856",
"datePublished": "2020-01-06T22:57:02.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:37:57.750Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7794 (GCVE-0-2018-7794)
Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:05
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) |
Affected:
Modicon M580
Affected: Modicon M340 Affected: Modicon Quantum Affected: Modicon Premium (see security notification for specific versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.272Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7794",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:04:08.954870Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:05:11.611Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M580"
},
{
"status": "affected",
"version": "Modicon M340"
},
{
"status": "affected",
"version": "Modicon Quantum"
},
{
"status": "affected",
"version": "Modicon Premium (see security notification for specific versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-06T22:57:09.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7794",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M580"
},
{
"version_value": "Modicon M340"
},
{
"version_value": "Modicon Quantum"
},
{
"version_value": "Modicon Premium (see security notification for specific versions)"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7794",
"datePublished": "2020-01-06T22:57:09.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:05:11.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7762 (GCVE-0-2018-7762)
Vulnerability from nvd – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
Severity
No CVSS data available.
CWE
- Buffer overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0203
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:58.095Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0203"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the web services to process SOAP requests in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0203"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in the web services to process SOAP requests in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7762",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:58.095Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7761 (GCVE-0-2018-7761)
Vulnerability from nvd – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
Severity
No CVSS data available.
CWE
- Arbritrary Code Execution
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0202
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:57.953Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0202"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the HTTP request parser in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbritrary Code Execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7761",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0202"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in the HTTP request parser in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Arbritrary Code Execution"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7761",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:57.953Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7760 (GCVE-0-2018-7760)
Vulnerability from nvd – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
Severity
No CVSS data available.
CWE
- Authorization Bypass
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0201
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.111Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0201"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An authorization bypass vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Authorization Bypass",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7760",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0201"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An authorization bypass vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authorization Bypass"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7760",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:59.111Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7759 (GCVE-0-2018-7759)
Vulnerability from nvd – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.
Severity
No CVSS data available.
CWE
- Buffer overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0200
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:57.979Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0200"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7759",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0200"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer overflow vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7759",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:57.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7242 (GCVE-0-2018-7242)
Vulnerability from nvd – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:24
VLAI
Summary
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.
Severity
No CVSS data available.
CWE
- Vulnerable Hash Algorithms
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01 | x_refsource_MISC |
| http://www.securityfocus.com/bid/103543 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200 |
Affected:
All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:24:11.352Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
},
{
"name": "103543",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103543"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerable hash algorithms exists in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Vulnerable Hash Algorithms",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-05T20:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
},
{
"name": "103543",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103543"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7242",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"version": {
"version_data": [
{
"version_value": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerable hash algorithms exists in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Vulnerable Hash Algorithms"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
},
{
"name": "103543",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103543"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7242",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:24:11.352Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7241 (GCVE-0-2018-7241)
Vulnerability from nvd – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:24
VLAI
Summary
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
Severity
No CVSS data available.
CWE
- Hard-coded accounts
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/103542 | vdb-entryx_refsource_BID |
| https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200 |
Affected:
All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:24:11.691Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "103542",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103542"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Hard coded accounts exist in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Hard-coded accounts",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-05T20:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "103542",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103542"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7241",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"version": {
"version_data": [
{
"version_value": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Hard coded accounts exist in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Hard-coded accounts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "103542",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103542"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7241",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:24:11.691Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7477 (GCVE-0-2020-7477)
Vulnerability from cvelistv5 – Published: 2020-03-23 19:14 – Updated: 2026-05-28 20:19
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet – 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions) |
Affected:
Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet – 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:18.651Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-7477",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T20:19:17.040046Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T20:19:32.265Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:14:31.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7477",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)",
"version": {
"version_data": [
{
"version_value": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7477",
"datePublished": "2020-03-23T19:14:31.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2026-05-28T20:19:32.265Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7794 (GCVE-0-2018-7794)
Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:05
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) |
Affected:
Modicon M580
Affected: Modicon M340 Affected: Modicon Quantum Affected: Modicon Premium (see security notification for specific versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.272Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-7794",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:04:08.954870Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:05:11.611Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M580"
},
{
"status": "affected",
"version": "Modicon M340"
},
{
"status": "affected",
"version": "Modicon Quantum"
},
{
"status": "affected",
"version": "Modicon Premium (see security notification for specific versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-06T22:57:09.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7794",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M580"
},
{
"version_value": "Modicon M340"
},
{
"version_value": "Modicon Quantum"
},
{
"version_value": "Modicon Premium (see security notification for specific versions)"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7794",
"datePublished": "2020-01-06T22:57:09.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:05:11.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6857 (GCVE-0-2019-6857)
Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:41
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) |
Affected:
Modicon M580
Affected: Modicon M340 Affected: Modicon Quantum Affected: Modicon Premium (see security notification for specific versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.438Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6857",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:39:16.673211Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:41:14.779Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M580"
},
{
"status": "affected",
"version": "Modicon M340"
},
{
"status": "affected",
"version": "Modicon Quantum"
},
{
"status": "affected",
"version": "Modicon Premium (see security notification for specific versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-21T23:03:43.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6857",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M580"
},
{
"version_value": "Modicon M340"
},
{
"version_value": "Modicon Quantum"
},
{
"version_value": "Modicon Premium (see security notification for specific versions)"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6857",
"datePublished": "2020-01-06T22:57:05.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:41:14.779Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6856 (GCVE-0-2019-6856)
Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2026-05-29 14:37
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) |
Affected:
Modicon M580
Affected: Modicon M340 Affected: Modicon Quantum Affected: Modicon Premium (see security notification for specific versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.415Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6856",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:36:59.205058Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:37:57.750Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Modicon M580"
},
{
"status": "affected",
"version": "Modicon M340"
},
{
"status": "affected",
"version": "Modicon Quantum"
},
{
"status": "affected",
"version": "Modicon Premium (see security notification for specific versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-21T23:04:36.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6856",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)",
"version": {
"version_data": [
{
"version_value": "Modicon M580"
},
{
"version_value": "Modicon M340"
},
{
"version_value": "Modicon Quantum"
},
{
"version_value": "Modicon Premium (see security notification for specific versions)"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6856",
"datePublished": "2020-01-06T22:57:02.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:37:57.750Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-7242 (GCVE-0-2018-7242)
Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:24
VLAI
Summary
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.
Severity
No CVSS data available.
CWE
- Vulnerable Hash Algorithms
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01 | x_refsource_MISC |
| http://www.securityfocus.com/bid/103543 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200 |
Affected:
All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:24:11.352Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
},
{
"name": "103543",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103543"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerable hash algorithms exists in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Vulnerable Hash Algorithms",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-05T20:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
},
{
"name": "103543",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103543"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7242",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"version": {
"version_data": [
{
"version_value": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerable hash algorithms exists in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Vulnerable Hash Algorithms"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
},
{
"name": "103543",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103543"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7242",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:24:11.352Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7759 (GCVE-0-2018-7759)
Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.
Severity
No CVSS data available.
CWE
- Buffer overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0200
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:57.979Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0200"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7759",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0200"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer overflow vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7759",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:57.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7761 (GCVE-0-2018-7761)
Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
Severity
No CVSS data available.
CWE
- Arbritrary Code Execution
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0202
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:57.953Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0202"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the HTTP request parser in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbritrary Code Execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7761",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0202"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in the HTTP request parser in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Arbritrary Code Execution"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7761",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:57.953Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7762 (GCVE-0-2018-7762)
Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
Severity
No CVSS data available.
CWE
- Buffer overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0203
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:58.095Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0203"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the web services to process SOAP requests in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0203"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in the web services to process SOAP requests in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7762",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:58.095Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7760 (GCVE-0-2018-7760)
Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:37
VLAI
Summary
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
Severity
No CVSS data available.
CWE
- Authorization Bypass
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201 |
Affected:
All Modicon M340, Premium, Quantum PLCs and BMXNOR0201
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.111Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0201"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An authorization bypass vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Authorization Bypass",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-18T19:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7760",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201",
"version": {
"version_data": [
{
"version_value": "All Modicon M340, Premium, Quantum PLCs and BMXNOR0201"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An authorization bypass vulnerability exists in Schneider Electric\u0027s Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authorization Bypass"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7760",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:59.111Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7241 (GCVE-0-2018-7241)
Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-08-05 06:24
VLAI
Summary
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
Severity
No CVSS data available.
CWE
- Hard-coded accounts
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/103542 | vdb-entryx_refsource_BID |
| https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200 |
Affected:
All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200
|
Date Public
2018-03-22 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:24:11.691Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "103542",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103542"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
],
"datePublic": "2018-03-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Hard coded accounts exist in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Hard-coded accounts",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-05T20:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "103542",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103542"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7241",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200",
"version": {
"version_data": [
{
"version_value": "All versions of communication modules for Modicon Premium, Quantum, M340 and BMXNOR0200"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Hard coded accounts exist in Schneider Electric\u0027s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Hard-coded accounts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01/"
},
{
"name": "103542",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103542"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7241",
"datePublished": "2018-04-18T20:00:00.000Z",
"dateReserved": "2018-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:24:11.691Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}