Search

Find a vulnerability

Search criteria

    3 vulnerabilities found for triconex_tristation_emulator by schneider-electric

    FKIE_CVE-2018-7803

    Vulnerability from fkie_nvd - Published: 2019-05-22 21:29 - Updated: 2026-06-17 02:03
    Summary
    A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant.
    Impacted products
    Vendor Product Version
    schneider-electric triconex_tristation_emulator 1.2.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "Triconex TriStation Emulator V1.2.0",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Triconex TriStation Emulator V1.2.0"
                }
              ]
            }
          ],
          "source": "cybersecurity@se.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:triconex_tristation_emulator:1.2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AB9CF5BE-97F7-4585-B9DF-B42D5EFE914D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant."
        },
        {
          "lang": "es",
          "value": "Una CWE-754: Existe una vulnerabilidad de Comprobaci\u00f3n Inapropiada  para condiciones inusuales o excepcionales en Triconex TriStation Emulator V1.2.0, que podr\u00eda hacer que el emulador se bloquee al enviar un paquete creado especialmente. El emulador se utiliza con poca frecuencia para pruebas l\u00f3gica de aplicaci\u00f3n. Es susceptible a un ataque solo mientras se ejecuta en modo Off-Line. Esta vulnerabilidad no existe en los productos de hardware de Triconex y por lo tanto no tiene efectos en las funciones de seguridad operativa en una planta."
        }
      ],
      "id": "CVE-2018-7803",
      "lastModified": "2026-06-17T02:03:46.000",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-05-22T21:29:00.277",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-754"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2018-7803 (GCVE-0-2018-7803)

    Vulnerability from nvd – Published: 2019-05-22 20:08 – Updated: 2024-08-05 06:37
    VLAI
    Summary
    A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant.
    Severity
    No CVSS data available.
    CWE
    • Improper Check for Unusual or Exceptional Conditions
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Triconex TriStation Emulator V1.2.0 Affected: Triconex TriStation Emulator V1.2.0
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.619Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Triconex TriStation Emulator V1.2.0",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Triconex TriStation Emulator V1.2.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-22T20:08:29.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7803",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Triconex TriStation Emulator V1.2.0",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Triconex TriStation Emulator V1.2.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03",
                  "refsource": "MISC",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7803",
        "datePublished": "2019-05-22T20:08:29.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:37:59.619Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7803 (GCVE-0-2018-7803)

    Vulnerability from cvelistv5 – Published: 2019-05-22 20:08 – Updated: 2024-08-05 06:37
    VLAI
    Summary
    A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant.
    Severity
    No CVSS data available.
    CWE
    • Improper Check for Unusual or Exceptional Conditions
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Triconex TriStation Emulator V1.2.0 Affected: Triconex TriStation Emulator V1.2.0
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.619Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Triconex TriStation Emulator V1.2.0",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Triconex TriStation Emulator V1.2.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-22T20:08:29.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7803",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Triconex TriStation Emulator V1.2.0",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Triconex TriStation Emulator V1.2.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03",
                  "refsource": "MISC",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7803",
        "datePublished": "2019-05-22T20:08:29.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:37:59.619Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }