Search

Find a vulnerability

Search criteria

    18 vulnerabilities found for tia_administrator by siemens

    FKIE_CVE-2026-111497

    Vulnerability from fkie_nvd - Published: 2026-10-22 14:17 - Updated: 2026-11-18 19:17
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    References
    cve-coordination@google.comhttps://github.com/andybalholm/brotli/releases/tag/v1.2.7Release Notes
    cve-coordination@google.comhttps://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---highThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/23/25Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/24/6Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/12Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/13Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/16Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/11/03/2Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://broccoli2shell.comThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/advisories/GHSA-9v8h-qqgm-4m35Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/dotnet/announcements/issues/494Issue Tracking, Mitigation, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.0.10Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.1.1Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.2.1Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2026/10/msg00049.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://patchtheplanet.org/brotliThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497Third Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-045512.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-242944.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-443410.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-678870.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-898633.htmlThird Party Advisory
    134c704f-9b21-4f2e-91b3-4a467353bcc0https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/Third Party Advisory
    134c704f-9b21-4f2e-91b3-4a467353bcc0https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497US Government Resource
    Impacted products
    Vendor Product Version
    google brotli *
    google brotli *
    google brotli *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    python-hyper brotlicffi *
    microsoft .net *
    microsoft .net *
    microsoft .net *
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    debian debian_linux 12.0
    istio istio *
    istio istio *
    istio istio *
    anthropic bun *
    envoyproxy envoy *
    envoyproxy envoy *
    envoyproxy envoy *
    tianocore edk2 *
    google woff2 -
    duckdb duckdb *
    clickhouse clickhouse *
    apache arrow *
    apache arrow 27.0.0
    mcmilk 7-zip-zstd *
    7-zip p7zip *
    andybalholm brotli *
    siemens ruggedcom_ape1808_firmware -
    siemens ruggedcom_ape1808 -
    siemens common_configurator -
    siemens data_flow_monitoring *
    siemens dataxess_configurator *
    siemens edge_opc_ua_server_configurator *
    siemens flow_creator_configurator *
    siemens industrial_edge_cloud_connector_configurator *
    siemens industrial_edge_databus_configurator *
    siemens industrial_edge_hub -
    siemens industrial_edge_management_cloud -
    siemens comos_walkinside -
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_profiling_tool -
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_wincc *
    siemens simatic_wincc_companion -
    siemens simatic_wincc_runtime -
    siemens simatic_wincc_unified_for_industrial_edge -
    siemens simatic_wincc_unified_pc_runtime -
    siemens simatic_wincc_unified_siqence -
    siemens tia_administrator -
    siemens tia_project-server_web_administration_tool -
    siemens user_management_component -
    siemens hyperlynx -
    siemens innexis_architecture_native_acceleration -
    siemens insights_hub -
    siemens opcenter_connect_electronics -
    siemens opcenter_connect_manufacturing_operations_management -
    siemens opcenter_execution_core -
    siemens opcenter_execution_discrete -
    siemens opcenter_execution_foundation -
    siemens opcenter_execution_pharma -
    siemens opcenter_execution_process -
    siemens opcenter_intelligence -
    siemens opcenter_quality -
    siemens opcenter_rd\&l -
    siemens opcenter_x -
    siemens pads_professional -
    siemens pads_professional -
    siemens pave360_automotive 2026
    siemens process_preparation_x -
    siemens simcenter_executable_digital_twin -
    siemens simcenter_studio -
    siemens teamcenter 2412.0
    siemens teamcenter 2506.0
    siemens teamcenter 2512.0
    siemens teamcenter 2606.0
    siemens xpedition_designer -
    siemens xpedition_enterprise -

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "cve-coordination@google.com"
        },
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 100 NX3 M8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 100 NX3 M8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 125 NX3 M10",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Gridscale X DSA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.4",
                  "status": "affected",
                  "version": "V5.3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Gridscale X PSS\u00aeE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V36.8.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Dual Port 60kW",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Flex Pro",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Integrated PA Suite Tester",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SENTRON Powermanager V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SENTRON Powermanager V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICAM PAS CC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V6.02",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICAM SCC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V7.01",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICHARGE FLEX",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICHARGE UC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Sifinity Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Sifinity Setup",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "VersiCharge AC Series",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "VersiCloud",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Cloud Connector Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.24.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Common Configurator\u00a0(CC on IEM)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Common Configurator on Device\u00a0(CC on Edge)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Data Flow Monitoring",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.18",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Databus Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "DataXess Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.5.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Edge OPC UA Server Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Flow Creator Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge Hub",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge Management Cloud",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "HyperLynx",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Innexis Architecture Native Acceleration 2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Insights Hub",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Connect Electronics",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Connect MOM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Core",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Discrete",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Pharma",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Process",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Intelligence",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Intra Plant Logistics",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter RDnL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Pro Essentials",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Pro Student Edition",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Professional",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PAVE360 Automotive 2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Process Preparation X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Executable Digital Twin",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Studio",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2606",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Xpedition Designer",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Xpedition Enterprise",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "COMOS Walkinside",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Project Server Web Administration Tool",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC BRAUMAT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2 Update 5",
                  "status": "affected",
                  "version": "V8.2 Update 1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Profiling Tool",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC SISTAR",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2 Update 5",
                  "status": "affected",
                  "version": "V8.2 Update 1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Companion",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC OA V3.20",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.20.17.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC OA V3.21",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.21.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Runtime Professional",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified for Industrial Edge",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified PC Runtime",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified SIQENCE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7/V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
        }
      ],
      "cisaActionDue": "2026-11-10",
      "cisaExploitAdd": "2026-10-27",
      "cisaRequiredAction": "Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA\u2019s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA\u2019s \u201cForensics Triage Requirements\u201d (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset\u0027s internet exposure and ensuring adherence to BOD 26-04 patching guidelines.",
      "cisaVulnerabilityName": "Google Brotli Unchecked Return Value Vulnerability",
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "8A7BE60F-21B0-4779-8D59-6E5E58C5826B",
                  "versionEndExcluding": "1.0.10",
                  "versionStartIncluding": "1.0.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "48E72297-AFBD-4460-A732-5A6803CCCDB0",
                  "versionEndExcluding": "1.1.1",
                  "versionStartIncluding": "1.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "C8CA5C74-26A8-44E3-B893-1FA01CED49F5",
                  "versionEndExcluding": "1.2.1",
                  "versionStartIncluding": "1.2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "02348F18-5E17-4427-8B78-63B4082F2FB4",
                  "versionEndExcluding": "22.23.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "852D09BB-A396-4813-81C9-7D89D5DD5FB6",
                  "versionEndExcluding": "24.22.1",
                  "versionStartIncluding": "23.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "219CA855-3A40-42CE-BAB6-79CCFEE7746F",
                  "versionEndExcluding": "26.12.1",
                  "versionStartIncluding": "25.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:python-hyper:brotlicffi:*:*:*:*:*:python:*:*",
                  "matchCriteriaId": "E732E75B-4BEF-4D7E-8520-E03B707FB4F6",
                  "versionEndExcluding": "1.2.1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "65DCE51C-2CD9-4179-9354-5323D28573AA",
                  "versionEndExcluding": "8.0.33",
                  "versionStartIncluding": "8.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "98654489-8C4E-4801-8728-29B01A22DEED",
                  "versionEndExcluding": "9.0.22",
                  "versionStartIncluding": "9.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "27DF5CF4-58E3-4F01-A3AA-D44B7DCC3D67",
                  "versionEndExcluding": "10.0.14",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview1:*:*:*:*:*:*",
                  "matchCriteriaId": "5DACF2FE-CF61-43E4-8A3F-F7A358DE8A01",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview2:*:*:*:*:*:*",
                  "matchCriteriaId": "280B2E64-3163-40AB-A048-14D58DEC42FD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview3:*:*:*:*:*:*",
                  "matchCriteriaId": "12357908-3294-46EF-85A0-DA3F86C97489",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview4:*:*:*:*:*:*",
                  "matchCriteriaId": "849FC8F5-86CD-4B5D-ADFD-9CB16EA75D09",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview5:*:*:*:*:*:*",
                  "matchCriteriaId": "C86E87E2-B236-4AC9-B6C3-64B9CDEC91EB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview6:*:*:*:*:*:*",
                  "matchCriteriaId": "9B14656E-2BB0-4B4B-B518-F3D5108253ED",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview7:*:*:*:*:*:*",
                  "matchCriteriaId": "E09C9DB3-F42C-4442-9CF0-24A780D094C8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc1:*:*:*:*:*:*",
                  "matchCriteriaId": "67035E86-61F5-421E-B243-EF64458AD8BA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc2:*:*:*:*:*:*",
                  "matchCriteriaId": "C46300CA-BA84-48B3-85C5-C20CB487C733",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:12.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "46D69DCC-AE4D-4EA5-861C-D60951444C6C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F01FA9D-7190-431F-84DD-24D4EBC41A2D",
                  "versionEndExcluding": "1.29.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8DE25CE-AFCB-4685-9836-B8EC9C820975",
                  "versionEndExcluding": "1.30.6",
                  "versionStartIncluding": "1.30.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "55EBE231-2EB8-4C9C-B279-D07F82EA5B55",
                  "versionEndExcluding": "1.31.2",
                  "versionStartIncluding": "1.31.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:anthropic:bun:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "51DD72B3-85F6-4B10-AEB4-41E0679ED0AA",
                  "versionEndExcluding": "1.4.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE6278D-A48A-427C-8A7E-1D4103E2ADF7",
                  "versionEndExcluding": "1.37.8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDCA301F-83CA-4DDB-AAE4-24D5235EE2D5",
                  "versionEndExcluding": "1.38.6",
                  "versionStartIncluding": "1.38.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B9A47DD3-2655-4722-9B9D-3888B590C82F",
                  "versionEndExcluding": "1.39.3",
                  "versionStartIncluding": "1.39.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C4CFCBFB-4A38-481B-93AE-7D86CCDC6FB5",
                  "versionEndIncluding": "202608",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:google:woff2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D1FC23A-20F7-48F7-ABB8-8D37903DFB58",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:duckdb:duckdb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0DFA4F95-92F9-4369-BE42-387520F0765B",
                  "versionEndIncluding": "2.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:clickhouse:clickhouse:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B40EE389-E2AC-4D86-91B2-79A895470317",
                  "versionEndIncluding": "26.10.2.103",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:apache:arrow:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "46A78CA5-1E4A-4DAA-B40D-387B96C1E2F9",
                  "versionEndIncluding": "26.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:apache:arrow:27.0.0:dev:*:*:*:*:*:*",
                  "matchCriteriaId": "130A7077-7885-43CB-8AFF-B6056D380156",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mcmilk:7-zip-zstd:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FB91A353-9BE9-49E7-86FD-6B5FBB291351",
                  "versionEndIncluding": "26.02-1.5.7-r2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:7-zip:p7zip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76A26292-08BE-459A-B25A-CA14AF8D3C29",
                  "versionEndIncluding": "16.02",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:andybalholm:brotli:*:*:*:*:*:go:*:*",
                  "matchCriteriaId": "F3E50F12-AEFE-4B4F-B474-3676F145E032",
                  "versionEndExcluding": "1.2.7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "37FDCA69-9049-40B4-88AF-F476901022B6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B89A6863-B602-4404-8D26-337FECABFFF0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:common_configurator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1F93AD0A-C29E-4FA6-A18B-1F0D03CC900C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:data_flow_monitoring:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3562BB8C-6E76-4B16-A2EF-D343EED30DA0",
                  "versionEndExcluding": "3.0.18",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:dataxess_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "076198F2-9992-4803-8377-8B264E1D7ADA",
                  "versionEndExcluding": "1.5.7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:edge_opc_ua_server_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F1122EBA-DB7C-4680-AEEF-309C95843D0D",
                  "versionEndExcluding": "2.3.10",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:flow_creator_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90BE4EB2-0B14-44F4-881D-F0DBAFCEF322",
                  "versionEndExcluding": "1.15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_cloud_connector_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0E0C6F6-40D0-4D71-ABCE-84449C4E743A",
                  "versionEndExcluding": "1.24.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_databus_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B57AD29D-69CF-4C76-AACA-3EAE3F8CBC15",
                  "versionEndExcluding": "4.0.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_hub:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "70BA5718-0A9F-4B7D-9175-D6719B795363",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_management_cloud:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4EA7E869-9428-4D5E-95C0-F19B6BC1BFA9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:comos_walkinside:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8C7AAED9-567F-4EE0-BC1B-F18E1109D316",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "EFA8804E-1E7E-482F-A701-B988F6C0BCE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "A7C12A3B-925A-4219-909B-6D2D0ADA6131",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "3288CF66-F9D9-4DDD-9CAA-1EB2E075C87A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "9B3EF16B-8281-4159-ABDE-A36881CD8460",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "9DF55BA1-F06B-4868-AC51-15ADC8BFED3C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_profiling_tool:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0D473CE5-B139-422C-AFCF-5FBBDB2C0759",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "28A180EC-5DB8-4E8A-B063-813FA3973068",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "31122237-42B0-4B10-B33B-D6E6DEBC19B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "2955D58B-350F-4F96-A41F-6594639403DA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "0E95149C-B212-4670-8DFC-EEC713E87741",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "173F36F4-23F4-4650-805F-25A9032AF64A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DA06F4BD-1512-4700-AD3E-25C6CDA60246",
                  "versionEndIncluding": "8.2",
                  "versionStartIncluding": "7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_companion:-:*:*:*:*:-:*:*",
                  "matchCriteriaId": "174C0674-3100-4CCB-B55E-6BB1FB8F8442",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
                  "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_for_industrial_edge:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4DC1EDC8-DA6D-476F-9656-0FB9809F9E30",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_pc_runtime:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49B72BEA-DE75-4A5E-8658-30E5EBBFFF69",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_siqence:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E2E193FF-ED70-432A-8B33-2453A8B2B21B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FC8C7680-9033-4ECF-9764-5179A4033F64",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_project-server_web_administration_tool:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14BA6E1D-4D4E-4133-8869-5ADEC9CE545C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:user_management_component:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7139EEDB-2DCD-4C55-9DAC-423FB5807D11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:hyperlynx:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "92D6ED26-34E3-46A6-B025-F7DC263AA75A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:innexis_architecture_native_acceleration:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BE57EA6F-BA70-409D-B037-EDD603FAC0B9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:insights_hub:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1B8E91A0-4BF0-4BDE-8F83-4FF374697A76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_connect_electronics:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0EC96381-D0C9-4949-86E7-1A1E8239A8F2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_connect_manufacturing_operations_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0F5FAC2-E6E0-4ECA-86B6-9D082C1D674B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_core:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0A6E1786-F0A9-498F-9DE9-F503B5DAD84A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F04BAB87-71BB-4AB4-BC42-F89616698EEF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE353B7-07A1-4B50-8A43-62577C2208EE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_pharma:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4CC50DA8-906E-4BD5-9861-668273EE3A76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CCA2643-1E89-49AE-B8CB-3A9CDA3031A6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E3FA7CB-6931-4D0C-A3E6-1BE71EA0D30F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "69EDC5E0-6CCE-4120-913C-E598E0FE2D24",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A12051E1-2DC9-47C6-A320-927D0A7B9F47",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:essentials:*:*:*",
                  "matchCriteriaId": "C9033337-D032-403D-8BBF-3EA50253A40E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:student:*:*:*",
                  "matchCriteriaId": "F06B80D2-6A35-4AF5-A07A-0F5C3370C3E7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pave360_automotive:2026:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8DBFD9C-B213-4238-B39C-D4B537523CB1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:process_preparation_x:-:*:*:*:-:*:*:*",
                  "matchCriteriaId": "FEBDB60C-D759-476D-AF06-3C0691FC72CF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simcenter_executable_digital_twin:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F6ACF933-A876-4DE5-BBA7-D5BF97DB1AB4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simcenter_studio:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8C684EC-BECB-4833-B1F9-F773225A6172",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2412.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "963C8AAA-D3E0-4B10-93AE-DB15619EC5EE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2506.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "261C46FE-1C63-4A1F-8C8E-FC331E8F119E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2512.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7946C16C-5B81-42D2-BA6D-C8AA8FD5AD0C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2606.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86E64B27-FE8F-45AD-BE78-219E4067F8DE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:xpedition_designer:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F52F6405-0228-4C3D-842F-839192076657",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:xpedition_enterprise:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD525494-2807-48EA-AED0-11B9CB5A6A9B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
        }
      ],
      "id": "CVE-2026-111497",
      "lastModified": "2026-11-18T19:17:27.513",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "PRESENT",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 9.2,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@google.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-111497",
              "options": [
                {
                  "exploitation": "active"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-23T00:00:00+00:00",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-10-22T14:17:37.190",
      "references": [
        {
          "source": "cve-coordination@google.com",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
        },
        {
          "source": "cve-coordination@google.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://broccoli2shell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Mitigation",
            "Third Party Advisory"
          ],
          "url": "https://github.com/dotnet/announcements/issues/494"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://patchtheplanet.org/brotli"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
        }
      ],
      "sourceIdentifier": "cve-coordination@google.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-252"
            },
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "cve-coordination@google.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-3449

    Vulnerability from fkie_nvd - Published: 2021-03-25 15:15 - Updated: 2026-10-08 22:17
    Summary
    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
    References
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
    openssl-security@openssl.orghttps://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    openssl-security@openssl.orghttps://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    openssl-security@openssl.orghttps://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    openssl-security@openssl.orghttps://security.gentoo.org/glsa/202103-03Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20240621-0006/
    openssl-security@openssl.orghttps://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    openssl-security@openssl.orghttps://www.debian.org/security/2021/dsa-4875Third Party Advisory
    openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    openssl-security@openssl.orghttps://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-05Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-06Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-09Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-10Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
    af854a3a-2127-422b-91ae-364da2661108https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202103-03Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
    af854a3a-2127-422b-91ae-364da2661108https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2021/dsa-4875Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-05Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-06Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-09Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-10Third Party Advisory
    Impacted products
    Vendor Product Version
    openssl openssl *
    debian debian_linux 9.0
    debian debian_linux 10.0
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    netapp active_iq_unified_manager -
    netapp cloud_volumes_ontap_mediator -
    netapp e-series_performance_analyzer -
    netapp oncommand_insight -
    netapp oncommand_workflow_automation -
    netapp ontap_select_deploy_administration_utility -
    netapp santricity_smi-s_provider -
    netapp snapcenter -
    netapp storagegrid -
    tenable log_correlation_engine *
    tenable nessus *
    tenable nessus_network_monitor 5.11.0
    tenable nessus_network_monitor 5.11.1
    tenable nessus_network_monitor 5.12.0
    tenable nessus_network_monitor 5.12.1
    tenable nessus_network_monitor 5.13.0
    tenable tenable.sc *
    fedoraproject fedora 34
    mcafee web_gateway 8.2.19
    mcafee web_gateway 9.2.10
    mcafee web_gateway 10.1.1
    mcafee web_gateway_cloud_service 8.2.19
    mcafee web_gateway_cloud_service 9.2.10
    mcafee web_gateway_cloud_service 10.1.1
    checkpoint quantum_security_management_firmware r80.40
    checkpoint quantum_security_management_firmware r81
    checkpoint quantum_security_management -
    checkpoint multi-domain_management_firmware r80.40
    checkpoint multi-domain_management_firmware r81
    checkpoint multi-domain_management -
    checkpoint quantum_security_gateway_firmware r80.40
    checkpoint quantum_security_gateway_firmware r81
    checkpoint quantum_security_gateway -
    oracle communications_communications_policy_management 12.6.0.0.0
    oracle enterprise_manager_for_storage_management 13.4.0.0
    oracle essbase 21.2
    oracle graalvm 19.3.5
    oracle graalvm 20.3.1.2
    oracle graalvm 21.0.0.2
    oracle jd_edwards_enterpriseone_tools *
    oracle jd_edwards_world_security a9.4
    oracle mysql_connectors *
    oracle mysql_server *
    oracle mysql_server *
    oracle mysql_workbench *
    oracle peoplesoft_enterprise_peopletools 8.57
    oracle peoplesoft_enterprise_peopletools 8.58
    oracle peoplesoft_enterprise_peopletools 8.59
    oracle primavera_unifier *
    oracle primavera_unifier 19.12
    oracle primavera_unifier 20.12
    oracle primavera_unifier 21.12
    oracle secure_backup *
    oracle secure_global_desktop 5.6
    oracle zfs_storage_appliance_kit 8.8
    sonicwall sma100_firmware *
    sonicwall sma100 -
    sonicwall capture_client 3.5
    sonicwall sonicos 7.0.1.0
    siemens ruggedcom_rcm1224_firmware *
    siemens ruggedcom_rcm1224 -
    siemens scalance_lpe9403_firmware *
    siemens scalance_lpe9403 -
    siemens scalance_m-800_firmware *
    siemens scalance_m-800 -
    siemens scalance_s602_firmware *
    siemens scalance_s602 -
    siemens scalance_s612_firmware *
    siemens scalance_s612 -
    siemens scalance_s615_firmware *
    siemens scalance_s615 -
    siemens scalance_s623_firmware *
    siemens scalance_s623 -
    siemens scalance_s627-2m_firmware *
    siemens scalance_s627-2m -
    siemens scalance_sc-600_firmware *
    siemens scalance_sc-600 -
    siemens scalance_w700_firmware *
    siemens scalance_w700 -
    siemens scalance_w1700_firmware *
    siemens scalance_w1700 -
    siemens scalance_xb-200_firmware *
    siemens scalance_xb-200 -
    siemens scalance_xc-200_firmware *
    siemens scalance_xc-200 -
    siemens scalance_xf-200ba_firmware *
    siemens scalance_xf-200ba -
    siemens scalance_xm-400_firmware *
    siemens scalance_xm-400 -
    siemens scalance_xp-200_firmware *
    siemens scalance_xp-200 -
    siemens scalance_xr-300wg_firmware *
    siemens scalance_xr-300wg -
    siemens scalance_xr524-8c_firmware *
    siemens scalance_xr524-8c -
    siemens scalance_xr526-8c_firmware *
    siemens scalance_xr526-8c -
    siemens scalance_xr528-6m_firmware *
    siemens scalance_xr528-6m -
    siemens scalance_xr552-12_firmware *
    siemens scalance_xr552-12 -
    siemens simatic_cloud_connect_7_firmware *
    siemens simatic_cloud_connect_7_firmware -
    siemens simatic_cloud_connect_7 -
    siemens simatic_cp_1242-7_gprs_v2_firmware *
    siemens simatic_cp_1242-7_gprs_v2_firmware -
    siemens simatic_cp_1242-7_gprs_v2 -
    siemens simatic_hmi_basic_panels_2nd_generation_firmware *
    siemens simatic_hmi_basic_panels_2nd_generation -
    siemens simatic_hmi_comfort_outdoor_panels_firmware *
    siemens simatic_hmi_comfort_outdoor_panels -
    siemens simatic_hmi_ktp_mobile_panels_firmware *
    siemens simatic_hmi_ktp_mobile_panels -
    siemens simatic_mv500_firmware *
    siemens simatic_mv500 -
    siemens simatic_net_cp_1243-1_firmware *
    siemens simatic_net_cp_1243-1 -
    siemens simatic_net_cp1243-7_lte_eu_firmware *
    siemens simatic_net_cp1243-7_lte_eu -
    siemens simatic_net_cp1243-7_lte_us_firmware *
    siemens simatic_net_cp1243-7_lte_us -
    siemens simatic_net_cp_1243-8_irc_firmware *
    siemens simatic_net_cp_1243-8_irc -
    siemens simatic_net_cp_1542sp-1_irc_firmware *
    siemens simatic_net_cp_1542sp-1_irc -
    siemens simatic_net_cp_1543-1_firmware *
    siemens simatic_net_cp_1543-1 -
    siemens simatic_net_cp_1543sp-1_firmware *
    siemens simatic_net_cp_1543sp-1 -
    siemens simatic_net_cp_1545-1_firmware *
    siemens simatic_net_cp_1545-1 -
    siemens simatic_pcs_7_telecontrol_firmware *
    siemens simatic_pcs_7_telecontrol -
    siemens simatic_pcs_neo_firmware *
    siemens simatic_pcs_neo -
    siemens simatic_pdm_firmware *
    siemens simatic_pdm -
    siemens simatic_process_historian_opc_ua_server_firmware *
    siemens simatic_process_historian_opc_ua_server -
    siemens simatic_rf166c_firmware *
    siemens simatic_rf166c -
    siemens simatic_rf185c_firmware *
    siemens simatic_rf185c -
    siemens simatic_rf186c_firmware *
    siemens simatic_rf186c -
    siemens simatic_rf186ci_firmware *
    siemens simatic_rf186ci -
    siemens simatic_rf188c_firmware *
    siemens simatic_rf188c -
    siemens simatic_rf188ci_firmware *
    siemens simatic_rf188ci -
    siemens simatic_rf360r_firmware *
    siemens simatic_rf360r -
    siemens simatic_s7-1200_cpu_1211c_firmware *
    siemens simatic_s7-1200_cpu_1211c -
    siemens simatic_s7-1200_cpu_1212c_firmware *
    siemens simatic_s7-1200_cpu_1212c -
    siemens simatic_s7-1200_cpu_1212fc_firmware *
    siemens simatic_s7-1200_cpu_1212fc -
    siemens simatic_s7-1200_cpu_1214_fc_firmware *
    siemens simatic_s7-1200_cpu_1214_fc -
    siemens simatic_s7-1200_cpu_1214c_firmware *
    siemens simatic_s7-1200_cpu_1214c -
    siemens simatic_s7-1200_cpu_1214_fc_firmware *
    siemens simatic_s7-1200_cpu_1214_fc -
    siemens simatic_s7-1200_cpu_1215_fc_firmware *
    siemens simatic_s7-1200_cpu_1215_fc -
    siemens simatic_s7-1200_cpu_1215c_firmware *
    siemens simatic_s7-1200_cpu_1215c -
    siemens simatic_s7-1200_cpu_1217c_firmware *
    siemens simatic_s7-1200_cpu_1217c -
    siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
    siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
    siemens sinamics_connect_300_firmware *
    siemens sinamics_connect_300 -
    siemens tim_1531_irc_firmware *
    siemens tim_1531_irc -
    siemens simatic_logon *
    siemens simatic_logon 1.5
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_telecontrol -
    siemens sinec_nms 1.0
    siemens sinec_nms 1.0
    siemens sinec_pni -
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinumerik_opc_ua_server *
    siemens tia_administrator *
    siemens sinec_infrastructure_network_services *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
                }
              ]
            }
          ],
          "source": "openssl-security@openssl.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8",
                  "versionEndExcluding": "1.1.1k",
                  "versionStartIncluding": "1.1.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*",
                  "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*",
                  "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*",
                  "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014",
                  "versionEndExcluding": "6.0.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30",
                  "versionEndIncluding": "8.13.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05",
                  "versionEndIncluding": "5.17.0",
                  "versionStartIncluding": "5.13.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982",
                  "versionEndExcluding": "9.2.6.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E",
                  "versionEndIncluding": "5.7.33",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB",
                  "versionEndIncluding": "8.0.23",
                  "versionStartIncluding": "8.0.15",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9",
                  "versionEndIncluding": "17.12",
                  "versionStartIncluding": "17.7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A",
                  "versionEndExcluding": "18.1.0.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D",
                  "versionEndExcluding": "10.2.1.0-17sv",
                  "versionStartIncluding": "10.2.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C",
                  "versionStartIncluding": "6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80",
                  "versionStartIncluding": "1.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491",
                  "versionStartIncluding": "2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB",
                  "versionEndExcluding": "3.0",
                  "versionStartIncluding": "2.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE",
                  "versionStartIncluding": "2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF",
                  "versionStartIncluding": "1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8",
                  "versionStartIncluding": "9.1.0.7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D",
                  "versionStartIncluding": "2019",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059",
                  "versionEndExcluding": "2.2",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A",
                  "versionStartIncluding": "1.6.0.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*",
                  "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*",
                  "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*",
                  "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*",
                  "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253",
                  "versionEndExcluding": "1.0.1.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031",
                  "versionEndIncluding": "10.12.0",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C",
                  "versionEndIncluding": "10.24.0",
                  "versionStartIncluding": "10.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A",
                  "versionEndIncluding": "12.12.0",
                  "versionStartIncluding": "12.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3",
                  "versionEndExcluding": "12.22.1",
                  "versionStartIncluding": "12.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482",
                  "versionEndIncluding": "14.14.0",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58",
                  "versionEndExcluding": "14.16.1",
                  "versionStartIncluding": "14.15.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3",
                  "versionEndExcluding": "15.14.0",
                  "versionStartIncluding": "15.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
        },
        {
          "lang": "es",
          "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)"
        }
      ],
      "id": "CVE-2021-3449",
      "lastModified": "2026-10-08T22:17:11.243",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-3449",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:05:43.522199Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-03-25T15:15:13.450",
      "references": [
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-10"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-10"
        }
      ],
      "sourceIdentifier": "openssl-security@openssl.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-476"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2025-23365

    Vulnerability from fkie_nvd - Published: 2025-07-08 11:15 - Updated: 2026-06-17 08:53
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.
    Impacted products
    Vendor Product Version
    siemens tia_administrator *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "43911B67-89C5-4858-8FD6-06F24E42E102",
                  "versionEndExcluding": "3.0.6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en TIA Administrator (todas las versiones anteriores a la V3.0.6). La aplicaci\u00f3n afectada permite a usuarios con pocos privilegios activar instalaciones sobrescribiendo archivos de cach\u00e9 y modificando la ruta de descarga. Esto permitir\u00eda a un atacante escalar privilegios y ejecutar c\u00f3digo arbitrario."
        }
      ],
      "id": "CVE-2025-23365",
      "lastModified": "2026-06-17T08:53:49.883",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-23365",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-07-08T14:26:04.504131Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-07-08T11:15:26.860",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-573669.html"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-284"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-23364

    Vulnerability from fkie_nvd - Published: 2025-07-08 11:15 - Updated: 2026-06-17 08:53
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly validates code signing certificates. This could allow an attacker to bypass the check and exceute arbitrary code during installations.
    Impacted products
    Vendor Product Version
    siemens tia_administrator *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "43911B67-89C5-4858-8FD6-06F24E42E102",
                  "versionEndExcluding": "3.0.6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3.0.6). The affected application improperly validates code signing certificates.\r\nThis could allow an attacker to bypass the check and exceute arbitrary code during installations."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en TIA Administrator (todas las versiones anteriores a la V3.0.6). La aplicaci\u00f3n afectada valida incorrectamente los certificados de firma de c\u00f3digo. Esto podr\u00eda permitir que un atacante omita la comprobaci\u00f3n y ejecute c\u00f3digo arbitrario durante las instalaciones."
        }
      ],
      "id": "CVE-2025-23364",
      "lastModified": "2026-06-17T08:53:49.383",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 6.2,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.5,
            "impactScore": 3.6,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.5,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 6.9,
              "baseSeverity": "MEDIUM",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "NONE",
              "vulnConfidentialityImpact": "NONE",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-23364",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-07-08T14:26:22.894853Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-07-08T11:15:26.683",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-573669.html"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-347"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-38533

    Vulnerability from fkie_nvd - Published: 2024-06-11 12:15 - Updated: 2026-06-17 06:10
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3 SP2). The affected component creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3 SP2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "tia_administrator",
              "vendor": "siemens",
              "versions": [
                {
                  "lessThan": "v3sp2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B97EEECD-CF90-4D12-9369-2087911A65FF",
                  "versionEndExcluding": "3.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:3.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "6641E5DC-8613-44F7-BECE-3B029D9E1633",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:3.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "55CA3EB4-384A-4151-9A9B-66E77C99C268",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3 SP2). The affected component creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en TIA Administrator (Todas las versiones \u0026lt; V3 SP2). El componente afectado crea archivos de descarga temporales en un directorio con permisos inseguros. Esto podr\u00eda permitir que cualquier atacante autenticado en Windows interrumpa el proceso de actualizaci\u00f3n."
        }
      ],
      "id": "CVE-2023-38533",
      "lastModified": "2026-06-17T06:10:40.397",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "LOW",
              "baseScore": 3.3,
              "baseSeverity": "LOW",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 1.4,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "LOW",
              "vulnConfidentialityImpact": "NONE",
              "vulnIntegrityImpact": "NONE",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-38533",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-06-11T13:18:41.492079Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-06-11T12:15:12.297",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-319319.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-319319.html"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-379"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2019-10915

    Vulnerability from fkie_nvd - Published: 2019-07-11 22:15 - Updated: 2026-06-17 02:11
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
    Impacted products
    Vendor Product Version
    siemens tia_administrator 1.0
    siemens sinetplan 2.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "TIA Administrator",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V1.0 SP1 Upd1"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:1.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "3DC7C974-2812-4760-B2AE-F264AD2335A9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:sinetplan:2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "77BA7DF4-7836-43FC-8163-86F0F9BC2FB7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en TIA Administrator (todas las versiones anteriores a V1.0 SP1 Upd1). La aplicaci\u00f3n web de configuraci\u00f3n integrada (TIA Administrator) permite ejecutar determinados comandos de la aplicaci\u00f3n sin la autenticaci\u00f3n apropiada. La vulnerabilidad podr\u00eda ser explotada por un atacante con acceso local en el sistema afectado. La explotaci\u00f3n con \u00e9xito no requiere privilegios ni interacci\u00f3n con el usuario. Un atacante podr\u00eda usar la vulnerabilidad para comprometer la confidencialidad, la integridad y la disponibilidad del sistema afectado. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad."
        }
      ],
      "id": "CVE-2019-10915",
      "lastModified": "2026-06-17T02:11:53.693",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-11T22:15:11.047",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/109124"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/109124"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from nvd – Published: 2026-10-22 13:35 – Updated: 2026-11-18 18:32
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 78/100 over 37 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens blueplanet 100 NX3 M8 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 125 NX3 M10 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 100 – 165 TL3 (HV) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Integrated PA Suite Tester Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICAM PAS CC Affected: V6.02 , < * (custom)
    Create a notification for this product.
    Siemens SICAM SCC Affected: V7.01 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < V3.0.18 (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < V4.0.1 (custom)
    Create a notification for this product.
    Siemens DataXess Configurator Affected: 0 , < V1.5.7 (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < V2.3.10 (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < V1.15.1 (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Innexis Architecture Native Acceleration 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Process Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intelligence Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intra Plant Logistics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Quality Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Essentials Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Student Edition Affected: 0 , < * (custom)
    Create a notification for this product.

    50 of 76 products shown. All of them on the page of CVE-2026-111497.

    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 125 NX3 M10",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Integrated PA Suite Tester",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM PAS CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V6.02",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM SCC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V7.01",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20.17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.21.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.4.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:29.836Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-18T18:32:29.836Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-23365 (GCVE-0-2025-23365)

    Vulnerability from nvd – Published: 2025-07-08 10:34 – Updated: 2025-07-08 16:11
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-07-08 14:26 UTC
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens TIA Administrator Affected: 0 , < V3.0.6 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23365",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-08T14:26:04.504131Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-08T16:11:49.350Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:30.226Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-573669.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23365",
        "datePublished": "2025-07-08T10:34:30.226Z",
        "dateReserved": "2025-01-14T14:17:17.382Z",
        "dateUpdated": "2025-07-08T16:11:49.350Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23364 (GCVE-0-2025-23364)

    Vulnerability from nvd – Published: 2025-07-08 10:34 – Updated: 2025-07-08 16:11
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly validates code signing certificates. This could allow an attacker to bypass the check and exceute arbitrary code during installations.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-07-08 14:26 UTC
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens TIA Administrator Affected: 0 , < V3.0.6 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23364",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-08T14:26:22.894853Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-08T16:11:54.563Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3.0.6). The affected application improperly validates code signing certificates.\r\nThis could allow an attacker to bypass the check and exceute arbitrary code during installations."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347: Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:28.904Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-573669.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23364",
        "datePublished": "2025-07-08T10:34:28.904Z",
        "dateReserved": "2025-01-14T14:16:18.187Z",
        "dateUpdated": "2025-07-08T16:11:54.563Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38533 (GCVE-0-2023-38533)

    Vulnerability from nvd – Published: 2024-06-11 11:14 – Updated: 2024-08-02 17:46
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3 SP2). The affected component creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-11 13:18 UTC
    CWE
    • CWE-379 - Creation of Temporary File in Directory with Insecure Permissions
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens TIA Administrator Affected: 0 , < V3 SP2 (custom)
    Create a notification for this product.
    siemens tia_administrator Affected: 0 , < v3sp2 (custom)
        cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "tia_administrator",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "v3sp2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-38533",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-11T13:18:41.492079Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-11T13:32:12.104Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:46:55.859Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-319319.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3 SP2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3 SP2). The affected component creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:T/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-379",
                  "description": "CWE-379: Creation of Temporary File in Directory with Insecure Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-11T14:20:02.683Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-319319.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-38533",
        "datePublished": "2024-06-11T11:14:55.951Z",
        "dateReserved": "2023-07-19T13:07:08.565Z",
        "dateUpdated": "2024-08-02T17:46:55.859Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3449 (GCVE-0-2021-3449)

    Vulnerability from nvd – Published: 2021-03-25 14:25 – Updated: 2026-10-08 21:13
    VLAI
    Title
    NULL pointer deref in signature_algorithms processing
    Summary
    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-08 21:05 UTC
    CWE
    • NULL pointer dereference
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 77/100 over 56 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20210325.txt
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://tools.cisco.com/security/center/content/C… vendor-advisory
    https://www.debian.org/security/2021/dsa-4875 vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/03/27/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/27/2 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/3 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/4 mailing-list
    https://security.gentoo.org/glsa/202103-03 vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://www.oracle.com/security-alerts/cpuApr2021.html
    https://www.tenable.com/security/tns-2021-10
    https://www.tenable.com/security/tns-2021-09
    https://security.netapp.com/advisory/ntap-2021051…
    https://security.netapp.com/advisory/ntap-2021032…
    https://security.FreeBSD.org/advisories/FreeBSD-S…
    https://www.tenable.com/security/tns-2021-06
    https://www.tenable.com/security/tns-2021-05
    https://kc.mcafee.com/corporate/index?page=conten…
    https://www.oracle.com//security-alerts/cpujul2021.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://kb.pulsesecure.net/articles/Pulse_Securit…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://lists.debian.org/debian-lts-announce/2021… mailing-list
    https://www.oracle.com/security-alerts/cpuoct2021.html
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://www.oracle.com/security-alerts/cpujul2022.html
    https://security.netapp.com/advisory/ntap-2024062…
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)
    Create a notification for this product.
    Date Public
    2021-03-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T16:53:17.609Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20210325.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
              },
              {
                "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
              },
              {
                "name": "DSA-4875",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-4875"
              },
              {
                "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
              },
              {
                "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
              },
              {
                "name": "GLSA-202103-03",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202103-03"
              },
              {
                "name": "FEDORA-2021-cbf14ab8f9",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-10"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-09"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-06"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-05"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
              },
              {
                "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T21:05:43.522199Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T21:13:50.095Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
            }
          ],
          "datePublic": "2021-03-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "NULL pointer dereference",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-21T19:05:57.096Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "url": "https://www.openssl.org/news/secadv/20210325.txt"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
            },
            {
              "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
            },
            {
              "name": "DSA-4875",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2021/dsa-4875"
            },
            {
              "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
            },
            {
              "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
            },
            {
              "name": "GLSA-202103-03",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202103-03"
            },
            {
              "name": "FEDORA-2021-cbf14ab8f9",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-10"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-09"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
            },
            {
              "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-06"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-05"
            },
            {
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
            },
            {
              "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
            },
            {
              "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
            },
            {
              "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
            }
          ],
          "title": "NULL pointer deref in signature_algorithms processing"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2021-3449",
        "datePublished": "2021-03-25T14:25:13.659Z",
        "dateReserved": "2021-03-17T00:00:00.000Z",
        "dateUpdated": "2026-10-08T21:13:50.095Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-10915 (GCVE-0-2019-10915)

    Vulnerability from nvd – Published: 2019-07-11 21:17 – Updated: 2024-08-04 22:40
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
    Severity
    No CVSS data available.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens AG TIA Administrator Affected: All versions < V1.0 SP1 Upd1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:40:15.369Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
              },
              {
                "name": "109124",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/109124"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "TIA Administrator",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V1.0 SP1 Upd1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-24T15:35:14.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
            },
            {
              "name": "109124",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/109124"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-10915",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "TIA Administrator",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V1.0 SP1 Upd1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
                },
                {
                  "name": "109124",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/109124"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-10915",
        "datePublished": "2019-07-11T21:17:46.000Z",
        "dateReserved": "2019-04-08T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:40:15.369Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from cvelistv5 – Published: 2026-10-22 13:35 – Updated: 2026-11-18 18:32
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 78/100 over 37 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens blueplanet 100 NX3 M8 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 125 NX3 M10 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 100 – 165 TL3 (HV) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Integrated PA Suite Tester Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICAM PAS CC Affected: V6.02 , < * (custom)
    Create a notification for this product.
    Siemens SICAM SCC Affected: V7.01 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < V3.0.18 (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < V4.0.1 (custom)
    Create a notification for this product.
    Siemens DataXess Configurator Affected: 0 , < V1.5.7 (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < V2.3.10 (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < V1.15.1 (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Innexis Architecture Native Acceleration 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Process Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intelligence Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intra Plant Logistics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Quality Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Essentials Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Student Edition Affected: 0 , < * (custom)
    Create a notification for this product.

    50 of 76 products shown. All of them on the page of CVE-2026-111497.

    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 125 NX3 M10",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Integrated PA Suite Tester",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM PAS CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V6.02",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM SCC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V7.01",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20.17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.21.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.4.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:29.836Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-18T18:32:29.836Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-23365 (GCVE-0-2025-23365)

    Vulnerability from cvelistv5 – Published: 2025-07-08 10:34 – Updated: 2025-07-08 16:11
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-07-08 14:26 UTC
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens TIA Administrator Affected: 0 , < V3.0.6 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23365",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-08T14:26:04.504131Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-08T16:11:49.350Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:30.226Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-573669.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23365",
        "datePublished": "2025-07-08T10:34:30.226Z",
        "dateReserved": "2025-01-14T14:17:17.382Z",
        "dateUpdated": "2025-07-08T16:11:49.350Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23364 (GCVE-0-2025-23364)

    Vulnerability from cvelistv5 – Published: 2025-07-08 10:34 – Updated: 2025-07-08 16:11
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly validates code signing certificates. This could allow an attacker to bypass the check and exceute arbitrary code during installations.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-07-08 14:26 UTC
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens TIA Administrator Affected: 0 , < V3.0.6 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23364",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-08T14:26:22.894853Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-08T16:11:54.563Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3.0.6). The affected application improperly validates code signing certificates.\r\nThis could allow an attacker to bypass the check and exceute arbitrary code during installations."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347: Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:28.904Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-573669.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23364",
        "datePublished": "2025-07-08T10:34:28.904Z",
        "dateReserved": "2025-01-14T14:16:18.187Z",
        "dateUpdated": "2025-07-08T16:11:54.563Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38533 (GCVE-0-2023-38533)

    Vulnerability from cvelistv5 – Published: 2024-06-11 11:14 – Updated: 2024-08-02 17:46
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V3 SP2). The affected component creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-11 13:18 UTC
    CWE
    • CWE-379 - Creation of Temporary File in Directory with Insecure Permissions
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens TIA Administrator Affected: 0 , < V3 SP2 (custom)
    Create a notification for this product.
    siemens tia_administrator Affected: 0 , < v3sp2 (custom)
        cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "tia_administrator",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "v3sp2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-38533",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-11T13:18:41.492079Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-11T13:32:12.104Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:46:55.859Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-319319.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3 SP2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V3 SP2). The affected component creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:T/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-379",
                  "description": "CWE-379: Creation of Temporary File in Directory with Insecure Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-11T14:20:02.683Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-319319.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-38533",
        "datePublished": "2024-06-11T11:14:55.951Z",
        "dateReserved": "2023-07-19T13:07:08.565Z",
        "dateUpdated": "2024-08-02T17:46:55.859Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3449 (GCVE-0-2021-3449)

    Vulnerability from cvelistv5 – Published: 2021-03-25 14:25 – Updated: 2026-10-08 21:13
    VLAI
    Title
    NULL pointer deref in signature_algorithms processing
    Summary
    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-08 21:05 UTC
    CWE
    • NULL pointer dereference
    Assigner
    openssl CNA under the mitre root
    CNA scorecard B 77/100 over 56 records in the last 180 days details
    References
    URL Tags
    https://www.openssl.org/news/secadv/20210325.txt
    https://git.openssl.org/gitweb/?p=openssl.git%3Ba…
    https://tools.cisco.com/security/center/content/C… vendor-advisory
    https://www.debian.org/security/2021/dsa-4875 vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/03/27/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/27/2 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/3 mailing-list
    http://www.openwall.com/lists/oss-security/2021/03/28/4 mailing-list
    https://security.gentoo.org/glsa/202103-03 vendor-advisory
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://www.oracle.com/security-alerts/cpuApr2021.html
    https://www.tenable.com/security/tns-2021-10
    https://www.tenable.com/security/tns-2021-09
    https://security.netapp.com/advisory/ntap-2021051…
    https://security.netapp.com/advisory/ntap-2021032…
    https://security.FreeBSD.org/advisories/FreeBSD-S…
    https://www.tenable.com/security/tns-2021-06
    https://www.tenable.com/security/tns-2021-05
    https://kc.mcafee.com/corporate/index?page=conten…
    https://www.oracle.com//security-alerts/cpujul2021.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://kb.pulsesecure.net/articles/Pulse_Securit…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://lists.debian.org/debian-lts-announce/2021… mailing-list
    https://www.oracle.com/security-alerts/cpuoct2021.html
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://www.oracle.com/security-alerts/cpujul2022.html
    https://security.netapp.com/advisory/ntap-2024062…
    Impacted products
    Vendor Product Version
    OpenSSL OpenSSL Affected: Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)
    Create a notification for this product.
    Date Public
    2021-03-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T16:53:17.609Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.openssl.org/news/secadv/20210325.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
              },
              {
                "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
              },
              {
                "name": "DSA-4875",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-4875"
              },
              {
                "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
              },
              {
                "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
              },
              {
                "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
              },
              {
                "name": "GLSA-202103-03",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202103-03"
              },
              {
                "name": "FEDORA-2021-cbf14ab8f9",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-10"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-09"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-06"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/tns-2021-05"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
              },
              {
                "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T21:05:43.522199Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T21:13:50.095Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
            }
          ],
          "datePublic": "2021-03-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "lang": "eng",
                  "url": "https://www.openssl.org/policies/secpolicy.html#High",
                  "value": "High"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "NULL pointer dereference",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-21T19:05:57.096Z",
            "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
            "shortName": "openssl"
          },
          "references": [
            {
              "url": "https://www.openssl.org/news/secadv/20210325.txt"
            },
            {
              "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
            },
            {
              "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
            },
            {
              "name": "DSA-4875",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2021/dsa-4875"
            },
            {
              "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
            },
            {
              "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
            },
            {
              "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
            },
            {
              "name": "GLSA-202103-03",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://security.gentoo.org/glsa/202103-03"
            },
            {
              "name": "FEDORA-2021-cbf14ab8f9",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-10"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-09"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
            },
            {
              "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-06"
            },
            {
              "url": "https://www.tenable.com/security/tns-2021-05"
            },
            {
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
            },
            {
              "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
            },
            {
              "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
            },
            {
              "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
            }
          ],
          "title": "NULL pointer deref in signature_algorithms processing"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "assignerShortName": "openssl",
        "cveId": "CVE-2021-3449",
        "datePublished": "2021-03-25T14:25:13.659Z",
        "dateReserved": "2021-03-17T00:00:00.000Z",
        "dateUpdated": "2026-10-08T21:13:50.095Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2019-10915 (GCVE-0-2019-10915)

    Vulnerability from cvelistv5 – Published: 2019-07-11 21:17 – Updated: 2024-08-04 22:40
    VLAI
    Summary
    A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
    Severity
    No CVSS data available.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens AG TIA Administrator Affected: All versions < V1.0 SP1 Upd1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:40:15.369Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
              },
              {
                "name": "109124",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/109124"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "TIA Administrator",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V1.0 SP1 Upd1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-24T15:35:14.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
            },
            {
              "name": "109124",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/109124"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-10915",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "TIA Administrator",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V1.0 SP1 Upd1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf"
                },
                {
                  "name": "109124",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/109124"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf"
                },
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-10915",
        "datePublished": "2019-07-11T21:17:46.000Z",
        "dateReserved": "2019-04-08T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:40:15.369Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }