Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for ti-rp262i_firmware by trendnet

    CVE-2021-33317 (GCVE-0-2021-33317)

    Vulnerability from nvd – Published: 2022-05-11 17:34 – Updated: 2024-08-03 23:50
    VLAI
    Summary
    The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from a null pointer dereference vulnerability. This vulnerability exists in its lldp related component. Due to fail to check if ChassisID TLV is contained in the packet, by sending a crafted lldp packet to the device, an attacker can crash the process due to null pointer dereference.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:50:41.433Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from a null pointer dereference vulnerability. This vulnerability exists in its lldp related component. Due to fail to check if ChassisID TLV is contained in the packet, by sending a crafted lldp packet to the device, an attacker can crash the process due to null pointer dereference."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-11T17:34:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33317",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from a null pointer dereference vulnerability. This vulnerability exists in its lldp related component. Due to fail to check if ChassisID TLV is contained in the packet, by sending a crafted lldp packet to the device, an attacker can crash the process due to null pointer dereference."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81",
                  "refsource": "MISC",
                  "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33317",
        "datePublished": "2022-05-11T17:34:25.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:50:41.433Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33316 (GCVE-0-2021-33316)

    Vulnerability from nvd – Published: 2022-05-11 17:34 – Updated: 2024-08-03 23:50
    VLAI
    Summary
    The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of ChassisID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:50:41.558Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of ChassisID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-11T17:34:24.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33316",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of ChassisID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81",
                  "refsource": "MISC",
                  "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33316",
        "datePublished": "2022-05-11T17:34:24.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:50:41.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33315 (GCVE-0-2021-33315)

    Vulnerability from nvd – Published: 2022-05-11 17:34 – Updated: 2024-08-03 23:50
    VLAI
    Summary
    The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of PortID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:50:41.420Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of PortID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-11T17:34:24.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33315",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of PortID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81",
                  "refsource": "MISC",
                  "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33315",
        "datePublished": "2022-05-11T17:34:24.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:50:41.420Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33317 (GCVE-0-2021-33317)

    Vulnerability from cvelistv5 – Published: 2022-05-11 17:34 – Updated: 2024-08-03 23:50
    VLAI
    Summary
    The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from a null pointer dereference vulnerability. This vulnerability exists in its lldp related component. Due to fail to check if ChassisID TLV is contained in the packet, by sending a crafted lldp packet to the device, an attacker can crash the process due to null pointer dereference.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:50:41.433Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from a null pointer dereference vulnerability. This vulnerability exists in its lldp related component. Due to fail to check if ChassisID TLV is contained in the packet, by sending a crafted lldp packet to the device, an attacker can crash the process due to null pointer dereference."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-11T17:34:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33317",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from a null pointer dereference vulnerability. This vulnerability exists in its lldp related component. Due to fail to check if ChassisID TLV is contained in the packet, by sending a crafted lldp packet to the device, an attacker can crash the process due to null pointer dereference."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81",
                  "refsource": "MISC",
                  "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33317",
        "datePublished": "2022-05-11T17:34:25.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:50:41.433Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33316 (GCVE-0-2021-33316)

    Vulnerability from cvelistv5 – Published: 2022-05-11 17:34 – Updated: 2024-08-03 23:50
    VLAI
    Summary
    The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of ChassisID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:50:41.558Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of ChassisID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-11T17:34:24.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33316",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of ChassisID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81",
                  "refsource": "MISC",
                  "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33316",
        "datePublished": "2022-05-11T17:34:24.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:50:41.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33315 (GCVE-0-2021-33315)

    Vulnerability from cvelistv5 – Published: 2022-05-11 17:34 – Updated: 2024-08-03 23:50
    VLAI
    Summary
    The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of PortID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:50:41.420Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of PortID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-11T17:34:24.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33315",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TRENDnet TI-PG1284i switch(hw v2.0R) prior to version 2.0.2.S0 suffers from an integer underflow vulnerability. This vulnerability exists in its lldp related component. Due to lack of proper validation on length field of PortID TLV, by sending a crafted lldp packet to the device, integer underflow would occur and the negative number will be passed to memcpy() later, which may cause buffer overflow or invalid memory access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81",
                  "refsource": "MISC",
                  "url": "https://www.trendnet.com/support/view.asp?cat=4\u0026id=81"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33315",
        "datePublished": "2022-05-11T17:34:24.000Z",
        "dateReserved": "2021-05-20T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:50:41.420Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }