Search
Find a vulnerability
Search criteria
26 vulnerabilities found for thingworx_industrial_connectivity by ptc
CVE-2023-29447 (GCVE-0-2023-29447)
Vulnerability from nvd – Published: 2024-01-10 20:24 – Updated: 2025-06-17 20:59
VLAI
EPSS
VEX
Title
Insufficiently Protected Credentials in PTC's Kepware KEPServerEX
Summary
An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication.
Severity
5.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
| https://www.dragos.com/advisory/ptcs-kepserverex-… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.417Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29447",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-11T02:38:36.071314Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T20:59:11.540Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication."
}
],
"value": "An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication."
}
],
"impacts": [
{
"capecId": "CAPEC-94",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-94 Man in the Middle Attack"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T15:45:53.226Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insufficiently Protected Credentials in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29447",
"datePublished": "2024-01-10T20:24:52.983Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2025-06-17T20:59:11.540Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29446 (GCVE-0-2023-29446)
Vulnerability from nvd – Published: 2024-01-10 20:21 – Updated: 2024-11-14 17:23
VLAI
EPSS
VEX
Title
Improper Input Validation in PTC's Kepware KEPServerEX
Summary
An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline.
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-40 - Path Traversal: '\\UNC\share\name\' (Windows UNC Share)
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
| https://www.dragos.com/advisory/ptcs-kepserverex-… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.304Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29446",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-14T17:23:25.379414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-14T17:23:37.514Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline.\u0026nbsp;"
}
],
"value": "An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline."
}
],
"impacts": [
{
"capecId": "CAPEC-644",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-644 Use of Captured Hashes (Pass The Hash)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-40",
"description": "CWE-40: Path Traversal: \u0027\\\\UNC\\share\\name\\\u0027 (Windows UNC Share)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T15:13:16.725Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Improper Input Validation in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29446",
"datePublished": "2024-01-10T20:21:51.434Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2024-11-14T17:23:37.514Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29445 (GCVE-0-2023-29445)
Vulnerability from nvd – Published: 2024-01-10 20:17 – Updated: 2025-06-17 20:59
VLAI
EPSS
VEX
Title
Uncontrolled Search Path Element in PTC's Kepware KEPServerEX
Summary
An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
| https://www.dragos.com/advisory/ptcs-kepserverex-… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.126Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29445",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-11T20:16:37.750500Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T20:59:11.408Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM."
}
],
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-10T20:17:12.837Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Uncontrolled Search Path Element in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29445",
"datePublished": "2024-01-10T20:17:12.837Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2025-06-17T20:59:11.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29444 (GCVE-0-2023-29444)
Vulnerability from nvd – Published: 2024-01-10 17:06 – Updated: 2025-05-14 20:14
VLAI
EPSS
VEX
Title
Uncontrolled Search Path Element in PTC's Kepware KEPServerEX
Summary
An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.269Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29444",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-14T20:14:08.179087Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-14T20:14:19.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution."
}
],
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-10T17:06:35.965Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Uncontrolled Search Path Element in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29444",
"datePublished": "2024-01-10T17:06:35.965Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2025-05-14T20:14:19.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5909 (GCVE-0-2023-5909)
Vulnerability from nvd – Published: 2023-11-30 22:05 – Updated: 2026-02-25 17:20
VLAI
EPSS
VEX
Title
Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx
Summary
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-297 - Improper Validation of Certificate with Host Mismatch
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| PTC | OPC-Aggregator |
Affected:
0 , ≤ 6.14
(custom)
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ 1.7
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| GE Gigital | Industrial Gateway Server |
Affected:
0 , ≤ 7.614
(custom)
|
|
| Software Toolbox | TOP Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:24.693Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5909",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-12-09T05:06:00.963177Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-25T17:20:07.195Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "OPC-Aggregator",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "1.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Gateway Server",
"vendor": "GE Gigital",
"versions": [
{
"lessThanOrEqual": "7.614",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TOP Server",
"vendor": "Software Toolbox",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Shawn Hoffman"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n"
}
],
"value": "\n\n\n\n\n\n\n\n\nKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-297",
"description": "CWE-297 Improper Validation of Certificate with Host Mismatch",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T22:05:59.595Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nPTC has released and recommends users to update to the following versions:\n\n * KEPServerEX should upgrade to v6.15 or later\n * ThingWorx Kepware Server should upgrade to v6.15 or later\n * ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n * OPC-Aggregator should upgrade to v6.15 or later\n * ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-5909",
"datePublished": "2023-11-30T22:05:59.595Z",
"dateReserved": "2023-11-01T16:18:45.060Z",
"dateUpdated": "2026-02-25T17:20:07.195Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-5908 (GCVE-0-2023-5908)
Vulnerability from nvd – Published: 2023-11-30 22:03 – Updated: 2024-08-02 08:14
VLAI
EPSS
VEX
Title
Heap Based Buffer Overflow in PTC KEPServerEx
Summary
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
Severity
9.1 (Critical)
CWE
- CWE-122 - Heap-Based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| PTC | OPC-Aggregator |
Affected:
0 , ≤ 6.14
(custom)
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ 1.7
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| GE Gigital | Industrial Gateway Server |
Affected:
0 , ≤ 7.614
(custom)
|
|
| Software Toolbox | TOP Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:24.586Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "OPC-Aggregator",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "1.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Gateway Server",
"vendor": "GE Gigital",
"versions": [
{
"lessThanOrEqual": "7.614",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TOP Server",
"vendor": "Software Toolbox",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Shawn Hoffman"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\u003c/p\u003e\u003cbr\u003e\n\n"
}
],
"value": "\n\n\n\n\nKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-Based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T22:03:58.098Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nPTC has released and recommends users to update to the following versions:\n\n * KEPServerEX should upgrade to v6.15 or later\n * ThingWorx Kepware Server should upgrade to v6.15 or later\n * ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n * OPC-Aggregator should upgrade to v6.15 or later\n * ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap Based Buffer Overflow in PTC KEPServerEx",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-5908",
"datePublished": "2023-11-30T22:03:58.098Z",
"dateReserved": "2023-11-01T16:18:42.353Z",
"dateUpdated": "2024-08-02T08:14:24.586Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2848 (GCVE-0-2022-2848)
Vulnerability from nvd – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:42
VLAI
EPSS
VEX
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kepware | KEPServerEX |
Affected:
6.11.718.0
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:58.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2848",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T15:45:30.371828Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T16:42:21.939Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "KEPServerEX",
"vendor": "Kepware",
"versions": [
{
"status": "affected",
"version": "6.11.718.0"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-20T00:00:00.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-2848",
"datePublished": "2023-03-29T00:00:00.000Z",
"dateReserved": "2022-08-16T00:00:00.000Z",
"dateUpdated": "2025-02-18T16:42:21.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2825 (GCVE-0-2022-2825)
Vulnerability from nvd – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:16
VLAI
EPSS
VEX
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
Severity
9.8 (Critical)
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kepware | KEPServerEX |
Affected:
6.11.718.0
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:58.837Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-2825",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T15:48:06.564232Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T16:16:11.214Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "KEPServerEX",
"vendor": "Kepware",
"versions": [
{
"status": "affected",
"version": "6.11.718.0"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-20T00:00:00.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-2825",
"datePublished": "2023-03-29T00:00:00.000Z",
"dateReserved": "2022-08-15T00:00:00.000Z",
"dateUpdated": "2025-02-18T16:16:11.214Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0755 (GCVE-0-2023-0755)
Vulnerability from nvd – Published: 2023-02-23 21:23 – Updated: 2025-01-16 21:55
VLAI
EPSS
VEX
Summary
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-129 - Improper Validation of Array Index
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | ThingWorx Edge C-SDK |
Affected:
0 , ≤ v2.2.12.1052
(custom)
|
|
| Microsoft | .NET-SDK |
Affected:
0 , ≤ v5.8.4.971
(custom)
|
|
| PTC | ThingWorx Edge MicroServer (EMS) |
Affected:
0 , ≤ v5.4.10.0
(custom)
|
|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All Versions
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ v1.5
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ v6.12
(custom)
|
|
| General Electric | Digital Industrial Gateway Server |
Affected:
0 , ≤ v7.612
(custom)
|
Date Public
2023-02-23 17:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.155Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-0755",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:59:08.379075Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:55:52.537Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge C-SDK",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v2.2.12.1052 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": ".NET-SDK",
"vendor": "Microsoft",
"versions": [
{
"lessThanOrEqual": "v5.8.4.971 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge MicroServer (EMS)",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v5.4.10.0 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server ",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions "
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v1.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise ",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "v6.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital Industrial Gateway Server ",
"vendor": "General Electric ",
"versions": [
{
"lessThanOrEqual": "v7.612",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
}
],
"datePublic": "2023-02-23T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\u003c/span\u003e\n\n"
}
],
"value": "\nThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-129",
"description": "CWE-129 Improper Validation of Array Index",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-23T21:23:19.210Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
}
],
"value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-0755",
"datePublished": "2023-02-23T21:23:19.210Z",
"dateReserved": "2023-02-08T20:21:34.258Z",
"dateUpdated": "2025-01-16T21:55:52.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0754 (GCVE-0-2023-0754)
Vulnerability from nvd – Published: 2023-02-23 21:27 – Updated: 2025-01-16 21:55
VLAI
EPSS
VEX
Summary
The affected products are vulnerable to an integer
overflow or wraparound, which could allow an attacker to crash the server and remotely
execute arbitrary code.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | ThingWorx Edge C-SDK |
Affected:
0 , ≤ v2.2.12.1052
(custom)
|
|
| Microsoft | .NET-SDK |
Affected:
0 , ≤ v5.8.4.971
(custom)
|
|
| PTC | ThingWorx Edge MicroServer (EMS) |
Affected:
0 , ≤ v5.4.10.0
(custom)
|
|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All Versions
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ v1.5
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ v6.12
(custom)
|
|
| General Electric | Digital Industrial Gateway Server |
Affected:
0 , ≤ v7.612
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.053Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-0754",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:59:05.493845Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:55:46.607Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge C-SDK",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v2.2.12.1052 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": ".NET-SDK",
"vendor": "Microsoft",
"versions": [
{
"lessThanOrEqual": "v5.8.4.971 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge MicroServer (EMS)",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v5.4.10.0 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server ",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions "
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v1.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise ",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "v6.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital Industrial Gateway Server ",
"vendor": "General Electric ",
"versions": [
{
"lessThanOrEqual": "v7.612",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u0026nbsp;allow an attacker to crash the server and remotely\nexecute arbitrary code.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003c/p\u003e\n\n\n\n\n\n"
}
],
"value": "\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u00a0allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-23T21:27:09.964Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
}
],
"value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-0754",
"datePublished": "2023-02-23T21:27:09.964Z",
"dateReserved": "2023-02-08T20:15:58.394Z",
"dateUpdated": "2025-01-16T21:55:46.607Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27267 (GCVE-0-2020-27267)
Vulnerability from nvd – Published: 2021-01-13 23:25 – Updated: 2024-08-04 16:11
VLAI
EPSS
VEX
Summary
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity
No CVSS data available.
CWE
- CWE-416 - USE AFTER FREE CWE-416
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | PTC Kepware KEPServerEX |
Affected:
v6.0 to v6.9
|
|
| n/a | ThingWorx Kepware Server |
Affected:
v6.8 and v6.9
|
|
| n/a | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| n/a | OPC-Aggregator |
Affected:
All versions
|
|
| n/a | Rockwell Automation KEPServer Enterprise |
Affected:
All versions
|
|
| n/a | GE Digital Industrial Gateway Server |
Affected:
v7.68.804
Affected: v7.66 |
|
| n/a | Software Toolbox TOP Server |
Affected:
All 6.x versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:11:36.412Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PTC Kepware KEPServerEX",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.0 to v6.9"
}
]
},
{
"product": "ThingWorx Kepware Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.8 and v6.9"
}
]
},
{
"product": "ThingWorx Industrial Connectivity",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "OPC-Aggregator",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Rockwell Automation KEPServer Enterprise",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "GE Digital Industrial Gateway Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v7.68.804"
},
{
"status": "affected",
"version": "v7.66"
}
]
},
{
"product": "Software Toolbox TOP Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All 6.x versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "USE AFTER FREE CWE-416",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-13T23:25:07.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-27267",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PTC Kepware KEPServerEX",
"version": {
"version_data": [
{
"version_value": "v6.0 to v6.9"
}
]
}
},
{
"product_name": "ThingWorx Kepware Server",
"version": {
"version_data": [
{
"version_value": "v6.8 and v6.9"
}
]
}
},
{
"product_name": "ThingWorx Industrial Connectivity",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "OPC-Aggregator",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Rockwell Automation KEPServer Enterprise",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "GE Digital Industrial Gateway Server",
"version": {
"version_data": [
{
"version_value": "v7.68.804"
},
{
"version_value": "v7.66"
}
]
}
},
{
"product_name": "Software Toolbox TOP Server",
"version": {
"version_data": [
{
"version_value": "All 6.x versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE AFTER FREE CWE-416"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-27267",
"datePublished": "2021-01-13T23:25:07.000Z",
"dateReserved": "2020-10-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:11:36.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27265 (GCVE-0-2020-27265)
Vulnerability from nvd – Published: 2021-01-13 23:33 – Updated: 2024-08-04 16:11
VLAI
EPSS
VEX
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
Severity
No CVSS data available.
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server |
Affected:
v6.0 to v6.9
Affected: v6.8 and v6.9 Affected: All versions Affected: v7.68.804, v7.66 Affected: All 6.x versions |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:11:36.330Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.0 to v6.9"
},
{
"status": "affected",
"version": "v6.8 and v6.9"
},
{
"status": "affected",
"version": "All versions"
},
{
"status": "affected",
"version": "v7.68.804, v7.66"
},
{
"status": "affected",
"version": "All 6.x versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-13T23:33:45.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-27265",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
"version": {
"version_data": [
{
"version_value": "v6.0 to v6.9"
},
{
"version_value": "v6.8 and v6.9"
},
{
"version_value": "All versions"
},
{
"version_value": "All versions"
},
{
"version_value": "All versions"
},
{
"version_value": "v7.68.804, v7.66"
},
{
"version_value": "All 6.x versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-27265",
"datePublished": "2021-01-13T23:33:45.000Z",
"dateReserved": "2020-10-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:11:36.330Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27263 (GCVE-0-2020-27263)
Vulnerability from nvd – Published: 2021-01-13 23:30 – Updated: 2024-08-04 16:11
VLAI
EPSS
VEX
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity
No CVSS data available.
CWE
- CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | PTC Kepware KEPServerEX |
Affected:
v6.0 to v6.9
|
|
| n/a | ThingWorx Kepware Server |
Affected:
v6.8 and v6.9
|
|
| n/a | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| n/a | OPC-Aggregator |
Affected:
All versions
|
|
| n/a | Rockwell Automation KEPServer Enterprise |
Affected:
All versions
|
|
| n/a | GE Digital Industrial Gateway Server |
Affected:
v7.68.804
Affected: v7.66 |
|
| n/a | Software Toolbox TOP Server |
Affected:
All 6.x versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:11:36.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PTC Kepware KEPServerEX",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.0 to v6.9"
}
]
},
{
"product": "ThingWorx Kepware Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.8 and v6.9"
}
]
},
{
"product": "ThingWorx Industrial Connectivity",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "OPC-Aggregator",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Rockwell Automation KEPServer Enterprise",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "GE Digital Industrial Gateway Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v7.68.804"
},
{
"status": "affected",
"version": "v7.66"
}
]
},
{
"product": "Software Toolbox TOP Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All 6.x versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-13T23:30:08.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-27263",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PTC Kepware KEPServerEX",
"version": {
"version_data": [
{
"version_value": "v6.0 to v6.9"
}
]
}
},
{
"product_name": "ThingWorx Kepware Server",
"version": {
"version_data": [
{
"version_value": "v6.8 and v6.9"
}
]
}
},
{
"product_name": "ThingWorx Industrial Connectivity",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "OPC-Aggregator",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Rockwell Automation KEPServer Enterprise",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "GE Digital Industrial Gateway Server",
"version": {
"version_data": [
{
"version_value": "v7.68.804"
},
{
"version_value": "v7.66"
}
]
}
},
{
"product_name": "Software Toolbox TOP Server",
"version": {
"version_data": [
{
"version_value": "All 6.x versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-27263",
"datePublished": "2021-01-13T23:30:08.000Z",
"dateReserved": "2020-10-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:11:36.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29447 (GCVE-0-2023-29447)
Vulnerability from cvelistv5 – Published: 2024-01-10 20:24 – Updated: 2025-06-17 20:59
VLAI
EPSS
VEX
Title
Insufficiently Protected Credentials in PTC's Kepware KEPServerEX
Summary
An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication.
Severity
5.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
| https://www.dragos.com/advisory/ptcs-kepserverex-… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.417Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29447",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-11T02:38:36.071314Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T20:59:11.540Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication."
}
],
"value": "An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication."
}
],
"impacts": [
{
"capecId": "CAPEC-94",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-94 Man in the Middle Attack"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T15:45:53.226Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insufficiently Protected Credentials in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29447",
"datePublished": "2024-01-10T20:24:52.983Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2025-06-17T20:59:11.540Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29446 (GCVE-0-2023-29446)
Vulnerability from cvelistv5 – Published: 2024-01-10 20:21 – Updated: 2024-11-14 17:23
VLAI
EPSS
VEX
Title
Improper Input Validation in PTC's Kepware KEPServerEX
Summary
An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline.
Severity
4.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-40 - Path Traversal: '\\UNC\share\name\' (Windows UNC Share)
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
| https://www.dragos.com/advisory/ptcs-kepserverex-… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.304Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29446",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-14T17:23:25.379414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-14T17:23:37.514Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline.\u0026nbsp;"
}
],
"value": "An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline."
}
],
"impacts": [
{
"capecId": "CAPEC-644",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-644 Use of Captured Hashes (Pass The Hash)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-40",
"description": "CWE-40: Path Traversal: \u0027\\\\UNC\\share\\name\\\u0027 (Windows UNC Share)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T15:13:16.725Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Improper Input Validation in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29446",
"datePublished": "2024-01-10T20:21:51.434Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2024-11-14T17:23:37.514Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29445 (GCVE-0-2023-29445)
Vulnerability from cvelistv5 – Published: 2024-01-10 20:17 – Updated: 2025-06-17 20:59
VLAI
EPSS
VEX
Title
Uncontrolled Search Path Element in PTC's Kepware KEPServerEX
Summary
An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
| https://www.dragos.com/advisory/ptcs-kepserverex-… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.126Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29445",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-11T20:16:37.750500Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T20:59:11.408Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM."
}
],
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-10T20:17:12.837Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
},
{
"url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Uncontrolled Search Path Element in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29445",
"datePublished": "2024-01-10T20:17:12.837Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2025-06-17T20:59:11.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29444 (GCVE-0-2023-29444)
Vulnerability from cvelistv5 – Published: 2024-01-10 17:06 – Updated: 2025-05-14 20:14
VLAI
EPSS
VEX
Title
Uncontrolled Search Path Element in PTC's Kepware KEPServerEX
Summary
An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
| https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(0)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
8.0 , ≤ 8.5
(0)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.269Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29444",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-14T20:14:08.179087Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-14T20:14:19.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "0"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "8.5",
"status": "affected",
"version": "8.0",
"versionType": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Sam Hanson of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution."
}
],
"value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-10T17:06:35.965Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ptc.com/en/support/article/cs399528"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Uncontrolled Search Path Element in PTC\u0027s Kepware KEPServerEX",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2023-29444",
"datePublished": "2024-01-10T17:06:35.965Z",
"dateReserved": "2023-04-06T17:45:40.441Z",
"dateUpdated": "2025-05-14T20:14:19.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5909 (GCVE-0-2023-5909)
Vulnerability from cvelistv5 – Published: 2023-11-30 22:05 – Updated: 2026-02-25 17:20
VLAI
EPSS
VEX
Title
Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx
Summary
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-297 - Improper Validation of Certificate with Host Mismatch
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| PTC | OPC-Aggregator |
Affected:
0 , ≤ 6.14
(custom)
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ 1.7
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| GE Gigital | Industrial Gateway Server |
Affected:
0 , ≤ 7.614
(custom)
|
|
| Software Toolbox | TOP Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:24.693Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5909",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-12-09T05:06:00.963177Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-25T17:20:07.195Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "OPC-Aggregator",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "1.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Gateway Server",
"vendor": "GE Gigital",
"versions": [
{
"lessThanOrEqual": "7.614",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TOP Server",
"vendor": "Software Toolbox",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Shawn Hoffman"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n"
}
],
"value": "\n\n\n\n\n\n\n\n\nKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-297",
"description": "CWE-297 Improper Validation of Certificate with Host Mismatch",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T22:05:59.595Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nPTC has released and recommends users to update to the following versions:\n\n * KEPServerEX should upgrade to v6.15 or later\n * ThingWorx Kepware Server should upgrade to v6.15 or later\n * ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n * OPC-Aggregator should upgrade to v6.15 or later\n * ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-5909",
"datePublished": "2023-11-30T22:05:59.595Z",
"dateReserved": "2023-11-01T16:18:45.060Z",
"dateUpdated": "2026-02-25T17:20:07.195Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-5908 (GCVE-0-2023-5908)
Vulnerability from cvelistv5 – Published: 2023-11-30 22:03 – Updated: 2024-08-02 08:14
VLAI
EPSS
VEX
Title
Heap Based Buffer Overflow in PTC KEPServerEx
Summary
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
Severity
9.1 (Critical)
CWE
- CWE-122 - Heap-Based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | KEPServerEX |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| PTC | OPC-Aggregator |
Affected:
0 , ≤ 6.14
(custom)
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ 1.7
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
|
| GE Gigital | Industrial Gateway Server |
Affected:
0 , ≤ 7.614
(custom)
|
|
| Software Toolbox | TOP Server |
Affected:
0 , ≤ 6.14.263.0
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:24.586Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "OPC-Aggregator",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "6.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "1.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Industrial Gateway Server",
"vendor": "GE Gigital",
"versions": [
{
"lessThanOrEqual": "7.614",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "TOP Server",
"vendor": "Software Toolbox",
"versions": [
{
"lessThanOrEqual": "6.14.263.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Shawn Hoffman"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\u003c/p\u003e\u003cbr\u003e\n\n"
}
],
"value": "\n\n\n\n\nKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-Based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T22:03:58.098Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nPTC has released and recommends users to update to the following versions:\n\n * KEPServerEX should upgrade to v6.15 or later\n * ThingWorx Kepware Server should upgrade to v6.15 or later\n * ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n * OPC-Aggregator should upgrade to v6.15 or later\n * ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap Based Buffer Overflow in PTC KEPServerEx",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-5908",
"datePublished": "2023-11-30T22:03:58.098Z",
"dateReserved": "2023-11-01T16:18:42.353Z",
"dateUpdated": "2024-08-02T08:14:24.586Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2825 (GCVE-0-2022-2825)
Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:16
VLAI
EPSS
VEX
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
Severity
9.8 (Critical)
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kepware | KEPServerEX |
Affected:
6.11.718.0
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:58.837Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-2825",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T15:48:06.564232Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T16:16:11.214Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "KEPServerEX",
"vendor": "Kepware",
"versions": [
{
"status": "affected",
"version": "6.11.718.0"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-20T00:00:00.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-2825",
"datePublished": "2023-03-29T00:00:00.000Z",
"dateReserved": "2022-08-15T00:00:00.000Z",
"dateUpdated": "2025-02-18T16:16:11.214Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2848 (GCVE-0-2022-2848)
Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:42
VLAI
EPSS
VEX
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kepware | KEPServerEX |
Affected:
6.11.718.0
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:58.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2848",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T15:45:30.371828Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T16:42:21.939Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "KEPServerEX",
"vendor": "Kepware",
"versions": [
{
"status": "affected",
"version": "6.11.718.0"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-20T00:00:00.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-2848",
"datePublished": "2023-03-29T00:00:00.000Z",
"dateReserved": "2022-08-16T00:00:00.000Z",
"dateUpdated": "2025-02-18T16:42:21.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0754 (GCVE-0-2023-0754)
Vulnerability from cvelistv5 – Published: 2023-02-23 21:27 – Updated: 2025-01-16 21:55
VLAI
EPSS
VEX
Summary
The affected products are vulnerable to an integer
overflow or wraparound, which could allow an attacker to crash the server and remotely
execute arbitrary code.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | ThingWorx Edge C-SDK |
Affected:
0 , ≤ v2.2.12.1052
(custom)
|
|
| Microsoft | .NET-SDK |
Affected:
0 , ≤ v5.8.4.971
(custom)
|
|
| PTC | ThingWorx Edge MicroServer (EMS) |
Affected:
0 , ≤ v5.4.10.0
(custom)
|
|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All Versions
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ v1.5
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ v6.12
(custom)
|
|
| General Electric | Digital Industrial Gateway Server |
Affected:
0 , ≤ v7.612
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.053Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-0754",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:59:05.493845Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:55:46.607Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge C-SDK",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v2.2.12.1052 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": ".NET-SDK",
"vendor": "Microsoft",
"versions": [
{
"lessThanOrEqual": "v5.8.4.971 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge MicroServer (EMS)",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v5.4.10.0 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server ",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions "
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v1.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise ",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "v6.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital Industrial Gateway Server ",
"vendor": "General Electric ",
"versions": [
{
"lessThanOrEqual": "v7.612",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u0026nbsp;allow an attacker to crash the server and remotely\nexecute arbitrary code.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003c/p\u003e\n\n\n\n\n\n"
}
],
"value": "\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u00a0allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-23T21:27:09.964Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
}
],
"value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-0754",
"datePublished": "2023-02-23T21:27:09.964Z",
"dateReserved": "2023-02-08T20:15:58.394Z",
"dateUpdated": "2025-01-16T21:55:46.607Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0755 (GCVE-0-2023-0755)
Vulnerability from cvelistv5 – Published: 2023-02-23 21:23 – Updated: 2025-01-16 21:55
VLAI
EPSS
VEX
Summary
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-129 - Improper Validation of Array Index
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | ThingWorx Edge C-SDK |
Affected:
0 , ≤ v2.2.12.1052
(custom)
|
|
| Microsoft | .NET-SDK |
Affected:
0 , ≤ v5.8.4.971
(custom)
|
|
| PTC | ThingWorx Edge MicroServer (EMS) |
Affected:
0 , ≤ v5.4.10.0
(custom)
|
|
| PTC | Kepware KEPServerEX |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Kepware Server |
Affected:
0 , ≤ v6.12
(custom)
|
|
| PTC | ThingWorx Industrial Connectivity |
Affected:
All Versions
|
|
| PTC | ThingWorx Kepware Edge |
Affected:
0 , ≤ v1.5
(custom)
|
|
| Rockwell Automation | KEPServer Enterprise |
Affected:
0 , ≤ v6.12
(custom)
|
|
| General Electric | Digital Industrial Gateway Server |
Affected:
0 , ≤ v7.612
(custom)
|
Date Public
2023-02-23 17:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.155Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-0755",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:59:08.379075Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:55:52.537Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge C-SDK",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v2.2.12.1052 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": ".NET-SDK",
"vendor": "Microsoft",
"versions": [
{
"lessThanOrEqual": "v5.8.4.971 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Edge MicroServer (EMS)",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v5.4.10.0 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Kepware KEPServerEX",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Server ",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v6.12 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Industrial Connectivity",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions "
}
]
},
{
"defaultStatus": "unaffected",
"product": "ThingWorx Kepware Edge",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "v1.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "KEPServer Enterprise ",
"vendor": "Rockwell Automation ",
"versions": [
{
"lessThanOrEqual": "v6.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital Industrial Gateway Server ",
"vendor": "General Electric ",
"versions": [
{
"lessThanOrEqual": "v7.612",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
}
],
"datePublic": "2023-02-23T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\u003c/span\u003e\n\n"
}
],
"value": "\nThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-129",
"description": "CWE-129 Improper Validation of Array Index",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-23T21:23:19.210Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
}
],
"value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-0755",
"datePublished": "2023-02-23T21:23:19.210Z",
"dateReserved": "2023-02-08T20:21:34.258Z",
"dateUpdated": "2025-01-16T21:55:52.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27265 (GCVE-0-2020-27265)
Vulnerability from cvelistv5 – Published: 2021-01-13 23:33 – Updated: 2024-08-04 16:11
VLAI
EPSS
VEX
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
Severity
No CVSS data available.
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server |
Affected:
v6.0 to v6.9
Affected: v6.8 and v6.9 Affected: All versions Affected: v7.68.804, v7.66 Affected: All 6.x versions |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:11:36.330Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.0 to v6.9"
},
{
"status": "affected",
"version": "v6.8 and v6.9"
},
{
"status": "affected",
"version": "All versions"
},
{
"status": "affected",
"version": "v7.68.804, v7.66"
},
{
"status": "affected",
"version": "All 6.x versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-13T23:33:45.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-27265",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
"version": {
"version_data": [
{
"version_value": "v6.0 to v6.9"
},
{
"version_value": "v6.8 and v6.9"
},
{
"version_value": "All versions"
},
{
"version_value": "All versions"
},
{
"version_value": "All versions"
},
{
"version_value": "v7.68.804, v7.66"
},
{
"version_value": "All 6.x versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-27265",
"datePublished": "2021-01-13T23:33:45.000Z",
"dateReserved": "2020-10-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:11:36.330Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27263 (GCVE-0-2020-27263)
Vulnerability from cvelistv5 – Published: 2021-01-13 23:30 – Updated: 2024-08-04 16:11
VLAI
EPSS
VEX
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity
No CVSS data available.
CWE
- CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | PTC Kepware KEPServerEX |
Affected:
v6.0 to v6.9
|
|
| n/a | ThingWorx Kepware Server |
Affected:
v6.8 and v6.9
|
|
| n/a | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| n/a | OPC-Aggregator |
Affected:
All versions
|
|
| n/a | Rockwell Automation KEPServer Enterprise |
Affected:
All versions
|
|
| n/a | GE Digital Industrial Gateway Server |
Affected:
v7.68.804
Affected: v7.66 |
|
| n/a | Software Toolbox TOP Server |
Affected:
All 6.x versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:11:36.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PTC Kepware KEPServerEX",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.0 to v6.9"
}
]
},
{
"product": "ThingWorx Kepware Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.8 and v6.9"
}
]
},
{
"product": "ThingWorx Industrial Connectivity",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "OPC-Aggregator",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Rockwell Automation KEPServer Enterprise",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "GE Digital Industrial Gateway Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v7.68.804"
},
{
"status": "affected",
"version": "v7.66"
}
]
},
{
"product": "Software Toolbox TOP Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All 6.x versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-13T23:30:08.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-27263",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PTC Kepware KEPServerEX",
"version": {
"version_data": [
{
"version_value": "v6.0 to v6.9"
}
]
}
},
{
"product_name": "ThingWorx Kepware Server",
"version": {
"version_data": [
{
"version_value": "v6.8 and v6.9"
}
]
}
},
{
"product_name": "ThingWorx Industrial Connectivity",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "OPC-Aggregator",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Rockwell Automation KEPServer Enterprise",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "GE Digital Industrial Gateway Server",
"version": {
"version_data": [
{
"version_value": "v7.68.804"
},
{
"version_value": "v7.66"
}
]
}
},
{
"product_name": "Software Toolbox TOP Server",
"version": {
"version_data": [
{
"version_value": "All 6.x versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-27263",
"datePublished": "2021-01-13T23:30:08.000Z",
"dateReserved": "2020-10-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:11:36.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27267 (GCVE-0-2020-27267)
Vulnerability from cvelistv5 – Published: 2021-01-13 23:25 – Updated: 2024-08-04 16:11
VLAI
EPSS
VEX
Summary
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity
No CVSS data available.
CWE
- CWE-416 - USE AFTER FREE CWE-416
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | PTC Kepware KEPServerEX |
Affected:
v6.0 to v6.9
|
|
| n/a | ThingWorx Kepware Server |
Affected:
v6.8 and v6.9
|
|
| n/a | ThingWorx Industrial Connectivity |
Affected:
All versions
|
|
| n/a | OPC-Aggregator |
Affected:
All versions
|
|
| n/a | Rockwell Automation KEPServer Enterprise |
Affected:
All versions
|
|
| n/a | GE Digital Industrial Gateway Server |
Affected:
v7.68.804
Affected: v7.66 |
|
| n/a | Software Toolbox TOP Server |
Affected:
All 6.x versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:11:36.412Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PTC Kepware KEPServerEX",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.0 to v6.9"
}
]
},
{
"product": "ThingWorx Kepware Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v6.8 and v6.9"
}
]
},
{
"product": "ThingWorx Industrial Connectivity",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "OPC-Aggregator",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Rockwell Automation KEPServer Enterprise",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "GE Digital Industrial Gateway Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "v7.68.804"
},
{
"status": "affected",
"version": "v7.66"
}
]
},
{
"product": "Software Toolbox TOP Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All 6.x versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "USE AFTER FREE CWE-416",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-13T23:25:07.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-27267",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PTC Kepware KEPServerEX",
"version": {
"version_data": [
{
"version_value": "v6.0 to v6.9"
}
]
}
},
{
"product_name": "ThingWorx Kepware Server",
"version": {
"version_data": [
{
"version_value": "v6.8 and v6.9"
}
]
}
},
{
"product_name": "ThingWorx Industrial Connectivity",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "OPC-Aggregator",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Rockwell Automation KEPServer Enterprise",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "GE Digital Industrial Gateway Server",
"version": {
"version_data": [
{
"version_value": "v7.68.804"
},
{
"version_value": "v7.66"
}
]
}
},
{
"product_name": "Software Toolbox TOP Server",
"version": {
"version_data": [
{
"version_value": "All 6.x versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE AFTER FREE CWE-416"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-27267",
"datePublished": "2021-01-13T23:25:07.000Z",
"dateReserved": "2020-10-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:11:36.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}