Search criteria

30 vulnerabilities found for talon_tc_modular_firmware by siemens

CVE-2021-31890 (GCVE-0-2021-31890)

Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
CWE
  • CWE-240 - Improper Handling of Inconsistent Structural Elements
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.798Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-240",
              "description": "CWE-240: Improper Handling of Inconsistent Structural Elements",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:46.741Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31890",
    "datePublished": "2021-11-09T11:32:02",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:46.741Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31889 (GCVE-0-2021-31889)

Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
CWE
  • CWE-191 - Integer Underflow (Wrap or Wraparound)
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-191",
              "description": "CWE-191: Integer Underflow (Wrap or Wraparound)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:45.226Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31889",
    "datePublished": "2021-11-09T11:32:01",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:45.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31888 (GCVE-0-2021-31888)

Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31888",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31888",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.804Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31887 (GCVE-0-2021-31887)

Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.650Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31887",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31887",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.650Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31886 (GCVE-0-2021-31886)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.838Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:35",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31886",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31886",
    "datePublished": "2021-11-09T11:31:59",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.838Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31885 (GCVE-0-2021-31885)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
Severity ?
No CVSS data available.
CWE
  • CWE-805 - Buffer Access with Incorrect Length Value
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus ReadyStart V4 Affected: All versions < V4.1.1
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens PLUSCONTROL 1st Gen Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.607Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-805",
              "description": "CWE-805: Buffer Access with Incorrect Length Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:34",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31885",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PLUSCONTROL 1st Gen",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-805: Buffer Access with Incorrect Length Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31885",
    "datePublished": "2021-11-09T11:31:58",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31884 (GCVE-0-2021-31884)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Capital VSTAR Affected: All versions with enabled Ethernet options
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.775Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Capital VSTAR",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions with enabled Ethernet options"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:33",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31884",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Capital VSTAR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions with enabled Ethernet options"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31884",
    "datePublished": "2021-11-09T11:31:57",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31883 (GCVE-0-2021-31883)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.182Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:43.750Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31883",
    "datePublished": "2021-11-09T11:31:56",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:43.750Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31882 (GCVE-0-2021-31882)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.782Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:42.320Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31882",
    "datePublished": "2021-11-09T11:31:55",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:42.320Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31881 (GCVE-0-2021-31881)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)
CWE
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.649Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:40.916Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31881",
    "datePublished": "2021-11-09T11:31:54",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:40.916Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31346 (GCVE-0-2021-31346)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
CWE
  • CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:39.488Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31346",
    "datePublished": "2021-11-09T11:31:53",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:39.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31345 (GCVE-0-2021-31345)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
CWE
  • CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.688Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:37.991Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31345",
    "datePublished": "2021-11-09T11:31:52",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:37.991Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31344 (GCVE-0-2021-31344)

Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)
CWE
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.529Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:36.591Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31344",
    "datePublished": "2021-11-09T11:31:51",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:36.591Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9947 (GCVE-0-2017-9947)

Vulnerability from nvd – Published: 2017-10-23 00:00 – Updated: 2024-08-05 17:25
VLAI?
Summary
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices.
Severity ?
No CVSS data available.
CWE
  • CWE-538 - File and Directory Information Exposure
Assigner
Impacted products
Vendor Product Version
n/a APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5 Affected: APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101248",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/101248"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5"
            }
          ]
        }
      ],
      "datePublic": "2017-10-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions \u003cV3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-538",
              "description": "CWE-538: File and Directory Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "101248",
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/101248"
        },
        {
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
        },
        {
          "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9947",
    "datePublished": "2017-10-23T00:00:00",
    "dateReserved": "2017-06-26T00:00:00",
    "dateUpdated": "2024-08-05T17:25:00.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9946 (GCVE-0-2017-9946)

Vulnerability from nvd – Published: 2017-10-23 00:00 – Updated: 2024-08-05 17:25
VLAI?
Summary
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.
Severity ?
No CVSS data available.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
n/a APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5 Affected: APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.381Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101248",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/101248"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5"
            }
          ]
        }
      ],
      "datePublic": "2017-10-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions \u003cV3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "101248",
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/101248"
        },
        {
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
        },
        {
          "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9946",
    "datePublished": "2017-10-23T00:00:00",
    "dateReserved": "2017-06-26T00:00:00",
    "dateUpdated": "2024-08-05T17:25:00.381Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31890 (GCVE-0-2021-31890)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
CWE
  • CWE-240 - Improper Handling of Inconsistent Structural Elements
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.798Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-240",
              "description": "CWE-240: Improper Handling of Inconsistent Structural Elements",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:46.741Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31890",
    "datePublished": "2021-11-09T11:32:02",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:46.741Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31889 (GCVE-0-2021-31889)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
CWE
  • CWE-191 - Integer Underflow (Wrap or Wraparound)
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-191",
              "description": "CWE-191: Integer Underflow (Wrap or Wraparound)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:45.226Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31889",
    "datePublished": "2021-11-09T11:32:01",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:45.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31887 (GCVE-0-2021-31887)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.650Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31887",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31887",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.650Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31888 (GCVE-0-2021-31888)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31888",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31888",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.804Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31886 (GCVE-0-2021-31886)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.838Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:35",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31886",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31886",
    "datePublished": "2021-11-09T11:31:59",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.838Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31885 (GCVE-0-2021-31885)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
Severity ?
No CVSS data available.
CWE
  • CWE-805 - Buffer Access with Incorrect Length Value
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus ReadyStart V4 Affected: All versions < V4.1.1
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens PLUSCONTROL 1st Gen Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.607Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-805",
              "description": "CWE-805: Buffer Access with Incorrect Length Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:34",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31885",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PLUSCONTROL 1st Gen",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-805: Buffer Access with Incorrect Length Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31885",
    "datePublished": "2021-11-09T11:31:58",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31884 (GCVE-0-2021-31884)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)
Severity ?
No CVSS data available.
CWE
  • CWE-170 - Improper Null Termination
Assigner
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MBC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (BACnet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE MEC (PPC) (P2 Ethernet) Affected: All versions
Create a notification for this product.
    Siemens APOGEE PXC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Compact (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens APOGEE PXC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens APOGEE PXC Modular (P2 Ethernet) Affected: All versions < V2.8.19
Create a notification for this product.
    Siemens Capital VSTAR Affected: All versions with enabled Ethernet options
Create a notification for this product.
    Siemens Desigo PXC00-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC00-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC001-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC100-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC12-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC128-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC200-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC22.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC36.1-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC50-E.D Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXC64-U Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Desigo PXM20-E Affected: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
    Siemens Nucleus NET Affected: All versions
Create a notification for this product.
    Siemens Nucleus ReadyStart V3 Affected: All versions < V2017.02.4
Create a notification for this product.
    Siemens Nucleus Source Code Affected: All versions
Create a notification for this product.
    Siemens TALON TC Compact (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
    Siemens TALON TC Modular (BACnet) Affected: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.775Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Capital VSTAR",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions with enabled Ethernet options"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:33",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31884",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Capital VSTAR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions with enabled Ethernet options"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31884",
    "datePublished": "2021-11-09T11:31:57",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31883 (GCVE-0-2021-31883)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.182Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:43.750Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31883",
    "datePublished": "2021-11-09T11:31:56",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:43.750Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31882 (GCVE-0-2021-31882)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.782Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:42.320Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31882",
    "datePublished": "2021-11-09T11:31:55",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:42.320Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31881 (GCVE-0-2021-31881)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)
CWE
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.649Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:40.916Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31881",
    "datePublished": "2021-11-09T11:31:54",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:40.916Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31346 (GCVE-0-2021-31346)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
CWE
  • CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:39.488Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31346",
    "datePublished": "2021-11-09T11:31:53",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:39.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31345 (GCVE-0-2021-31345)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
CWE
  • CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.688Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:37.991Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31345",
    "datePublished": "2021-11-09T11:31:52",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:37.991Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31344 (GCVE-0-2021-31344)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47
VLAI?
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)
CWE
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.529Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:36.591Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31344",
    "datePublished": "2021-11-09T11:31:51",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:36.591Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9947 (GCVE-0-2017-9947)

Vulnerability from cvelistv5 – Published: 2017-10-23 00:00 – Updated: 2024-08-05 17:25
VLAI?
Summary
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices.
Severity ?
No CVSS data available.
CWE
  • CWE-538 - File and Directory Information Exposure
Assigner
Impacted products
Vendor Product Version
n/a APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5 Affected: APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101248",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/101248"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5"
            }
          ]
        }
      ],
      "datePublic": "2017-10-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions \u003cV3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-538",
              "description": "CWE-538: File and Directory Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "101248",
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/101248"
        },
        {
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
        },
        {
          "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9947",
    "datePublished": "2017-10-23T00:00:00",
    "dateReserved": "2017-06-26T00:00:00",
    "dateUpdated": "2024-08-05T17:25:00.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9946 (GCVE-0-2017-9946)

Vulnerability from cvelistv5 – Published: 2017-10-23 00:00 – Updated: 2024-08-05 17:25
VLAI?
Summary
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.
Severity ?
No CVSS data available.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
n/a APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5 Affected: APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.381Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101248",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/101248"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5"
            }
          ]
        }
      ],
      "datePublic": "2017-10-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions \u003cV3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "101248",
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/101248"
        },
        {
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
        },
        {
          "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9946",
    "datePublished": "2017-10-23T00:00:00",
    "dateReserved": "2017-06-26T00:00:00",
    "dateUpdated": "2024-08-05T17:25:00.381Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}