Search
Find a vulnerability
Search criteria
18 vulnerabilities found for system_interface_foundation by lenovo
CVE-2021-3969 (GCVE-0-2021-3969)
Vulnerability from nvd – Published: 2022-05-18 16:10 – Updated: 2024-08-03 17:09
VLAI
Summary
A Time of Check Time of Use (TOCTOU) vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3that could allow a local attacker to elevate privileges.
Severity
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | IMController |
Affected:
unspecified , < 1.1.20.3
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:09:09.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IMController",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.20.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A Time of Check Time of Use (TOCTOU) vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3that could allow a local attacker to elevate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-18T16:10:25.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"solutions": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3969",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IMController",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.20.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Time of Check Time of Use (TOCTOU) vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3that could allow a local attacker to elevate privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-75210",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3969",
"datePublished": "2022-05-18T16:10:25.000Z",
"dateReserved": "2021-11-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:09:09.613Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3922 (GCVE-0-2021-3922)
Vulnerability from nvd – Published: 2022-05-18 16:10 – Updated: 2024-08-03 17:09
VLAI
Summary
A race condition vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3 that could allow a local attacker to connect and interact with the IMController child process' named pipe.
Severity
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | IMController |
Affected:
unspecified , < 1.1.20.3
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:09:09.782Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IMController",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.20.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A race condition vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3 that could allow a local attacker to connect and interact with the IMController child process\u0027 named pipe."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-18T16:10:22.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"solutions": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3922",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IMController",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.20.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A race condition vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3 that could allow a local attacker to connect and interact with the IMController child process\u0027 named pipe."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-75210",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3922",
"datePublished": "2022-05-18T16:10:22.000Z",
"dateReserved": "2021-11-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:09:09.782Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8346 (GCVE-0-2020-8346)
Vulnerability from nvd – Published: 2020-09-15 14:20 – Updated: 2024-09-17 04:18
VLAI
Summary
A denial of service vulnerability was reported in the Lenovo Vantage component called Lenovo System Interface Foundation prior to version 1.1.19.5 that could allow configuration files to be written to non-standard locations.
Severity
5.5 (Medium)
CWE
- CWE-276 - Incorrect Default Permissions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | System Interface Foundation |
Affected:
unspecified , < 1.1.19.5
(custom)
|
Date Public
2020-09-15 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-38717"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.19.5",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Samet Bekmezci for reporting this issue."
}
],
"datePublic": "2020-09-15T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability was reported in the Lenovo Vantage component called Lenovo System Interface Foundation prior to version 1.1.19.5 that could allow configuration files to be written to non-standard locations."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-15T14:20:18.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-38717"
}
],
"solutions": [
{
"lang": "en",
"value": "To update Lenovo System Interface Foundation to version 1.1.19.5 or later, follow these steps: Update Lenovo Vantage to the latest version from the Microsoft Store. Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-38717",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-09-15T16:00:00.000Z",
"ID": "CVE-2020-8346",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.19.5"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Samet Bekmezci for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A denial of service vulnerability was reported in the Lenovo Vantage component called Lenovo System Interface Foundation prior to version 1.1.19.5 that could allow configuration files to be written to non-standard locations."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276 Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-38717",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-38717"
}
]
},
"solution": [
{
"lang": "en",
"value": "To update Lenovo System Interface Foundation to version 1.1.19.5 or later, follow these steps: Update Lenovo Vantage to the latest version from the Microsoft Store. Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-38717",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8346",
"datePublished": "2020-09-15T14:20:18.491Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-17T04:18:52.614Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8324 (GCVE-0-2020-8324)
Vulnerability from nvd – Published: 2020-04-14 21:05 – Updated: 2024-09-16 18:44
VLAI
Summary
A vulnerability was reported in LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation prior to version 1.2.184.31 that could allow unsigned DLL files to be executed.
Severity
5 (Medium)
CWE
- CWE-347 - Improper Verification of Cryptographic Signature
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation |
Affected:
unspecified , < 1.2.184.31
(custom)
|
Date Public
2020-04-14 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.363Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.2.184.31",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"datePublic": "2020-04-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation prior to version 1.2.184.31 that could allow unsigned DLL files to be executed."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347 Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-14T21:05:20.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"solutions": [
{
"lang": "en",
"value": "Update LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation to version 1.2.184.31. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
"ID": "CVE-2020-8324",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.2.184.31"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was reported in LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation prior to version 1.2.184.31 that could allow unsigned DLL files to be executed."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-347 Improper Verification of Cryptographic Signature"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation to version 1.2.184.31. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8324",
"datePublished": "2020-04-14T21:05:20.866Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:44:12.684Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8319 (GCVE-0-2020-8319)
Vulnerability from nvd – Published: 2020-04-14 21:05 – Updated: 2024-09-16 17:27
VLAI
Summary
A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges.
Severity
7.3 (High)
CWE
- Privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Lenovo System Interface Foundation |
Affected:
unspecified , < 1.1.19.3
(custom)
|
Date Public
2020-04-14 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.19.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"datePublic": "2020-04-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-14T21:05:20.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.19.3. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
"ID": "CVE-2020-8319",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.19.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.19.3. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8319",
"datePublished": "2020-04-14T21:05:20.446Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:27:40.189Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8318 (GCVE-0-2020-8318)
Vulnerability from nvd – Published: 2020-04-14 21:05 – Updated: 2024-09-16 22:56
VLAI
Summary
A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges.
Severity
7.3 (High)
CWE
- Privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | LenovoSystemUpdatePlugin for Lenovo System Interface Foundation |
Affected:
unspecified , < 2.0.0.92
(custom)
|
Date Public
2020-04-14 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.350Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "2.0.0.92",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"datePublic": "2020-04-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-14T21:05:19.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"solutions": [
{
"lang": "en",
"value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
"ID": "CVE-2020-8318",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "2.0.0.92"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8318",
"datePublished": "2020-04-14T21:05:20.039Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:56:31.781Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6189 (GCVE-0-2019-6189)
Vulnerability from nvd – Published: 2019-11-20 01:31 – Updated: 2024-09-16 20:16
VLAI
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL.
Severity
No CVSS data available.
CWE
- local privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/solutions/LEN-29198 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Lenovo System Interface Foundation |
Unknown:
unspecified , ≤ 1.1.18.3
(custom)
|
Date Public
2019-11-19 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:16:24.514Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThanOrEqual": "1.1.18.3",
"status": "unknown",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-11-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-20T01:31:14.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.8"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
"ID": "CVE-2019-6189",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "?\u003c=",
"version_value": "1.1.18.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.8"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/solutions/LEN-29198",
"refsource": "MISC",
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2019-6189",
"datePublished": "2019-11-20T01:31:14.196Z",
"dateReserved": "2019-01-11T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:16:34.199Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6186 (GCVE-0-2019-6186)
Vulnerability from nvd – Published: 2019-11-20 01:31 – Updated: 2024-09-16 17:23
VLAI
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user.
Severity
No CVSS data available.
CWE
- local privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/solutions/LEN-29198 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Lenovo System Interface Foundation |
Unknown:
unspecified , ≤ 1.1.18.3
(custom)
|
Date Public
2019-11-19 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:16:23.842Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThanOrEqual": "1.1.18.3",
"status": "unknown",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-11-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-20T01:31:13.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.8"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
"ID": "CVE-2019-6186",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "?\u003c=",
"version_value": "1.1.18.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.8"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/solutions/LEN-29198",
"refsource": "MISC",
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2019-6186",
"datePublished": "2019-11-20T01:31:13.404Z",
"dateReserved": "2019-01-11T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:23:01.398Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-8223 (GCVE-0-2016-8223)
Vulnerability from nvd – Published: 2016-11-29 20:00 – Updated: 2024-08-06 02:13
VLAI
Summary
During an internal security review, Lenovo identified a local privilege escalation vulnerability in Lenovo System Interface Foundation software installed on some Windows 10 PCs where a user with local privileges could run arbitrary code with administrator level privileges.
Severity
No CVSS data available.
CWE
- Lenovo System Interface Foundation Privilege Escalation?
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/solutions/LEN_10150 | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/94597 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo Group Ltd. | All ThinkPad, ThinkCentre, ThinkStation and Lenovo-branded systems preloaded with the Windows 10 operating system, or any system running Lenovo Companion, Lenovo Settings, or Lenovo ID. |
Affected:
1.0.66.0 and earlier
|
Date Public
2016-11-17 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:13:21.875Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/solutions/LEN_10150"
},
{
"name": "94597",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/94597"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "All ThinkPad, ThinkCentre, ThinkStation and Lenovo-branded systems preloaded with the Windows 10 operating system, or any system running Lenovo Companion, Lenovo Settings, or Lenovo ID.",
"vendor": "Lenovo Group Ltd.",
"versions": [
{
"status": "affected",
"version": "1.0.66.0 and earlier"
}
]
}
],
"datePublic": "2016-11-17T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "During an internal security review, Lenovo identified a local privilege escalation vulnerability in Lenovo System Interface Foundation software installed on some Windows 10 PCs where a user with local privileges could run arbitrary code with administrator level privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Lenovo System Interface Foundation Privilege Escalation?",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-01T10:57:01.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.lenovo.com/us/en/solutions/LEN_10150"
},
{
"name": "94597",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/94597"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2016-8223",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "All ThinkPad, ThinkCentre, ThinkStation and Lenovo-branded systems preloaded with the Windows 10 operating system, or any system running Lenovo Companion, Lenovo Settings, or Lenovo ID.",
"version": {
"version_data": [
{
"version_value": "1.0.66.0 and earlier"
}
]
}
}
]
},
"vendor_name": "Lenovo Group Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "During an internal security review, Lenovo identified a local privilege escalation vulnerability in Lenovo System Interface Foundation software installed on some Windows 10 PCs where a user with local privileges could run arbitrary code with administrator level privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Lenovo System Interface Foundation Privilege Escalation?"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/solutions/LEN_10150",
"refsource": "CONFIRM",
"url": "https://support.lenovo.com/us/en/solutions/LEN_10150"
},
{
"name": "94597",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/94597"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2016-8223",
"datePublished": "2016-11-29T20:00:00.000Z",
"dateReserved": "2016-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-06T02:13:21.875Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3969 (GCVE-0-2021-3969)
Vulnerability from cvelistv5 – Published: 2022-05-18 16:10 – Updated: 2024-08-03 17:09
VLAI
Summary
A Time of Check Time of Use (TOCTOU) vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3that could allow a local attacker to elevate privileges.
Severity
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | IMController |
Affected:
unspecified , < 1.1.20.3
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:09:09.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IMController",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.20.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A Time of Check Time of Use (TOCTOU) vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3that could allow a local attacker to elevate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-18T16:10:25.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"solutions": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3969",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IMController",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.20.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Time of Check Time of Use (TOCTOU) vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3that could allow a local attacker to elevate privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-75210",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3969",
"datePublished": "2022-05-18T16:10:25.000Z",
"dateReserved": "2021-11-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:09:09.613Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3922 (GCVE-0-2021-3922)
Vulnerability from cvelistv5 – Published: 2022-05-18 16:10 – Updated: 2024-08-03 17:09
VLAI
Summary
A race condition vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3 that could allow a local attacker to connect and interact with the IMController child process' named pipe.
Severity
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | IMController |
Affected:
unspecified , < 1.1.20.3
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:09:09.782Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IMController",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.20.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A race condition vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3 that could allow a local attacker to connect and interact with the IMController child process\u0027 named pipe."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-18T16:10:22.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
],
"solutions": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3922",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IMController",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.20.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Rick Veldhoven from Fox-IT, part of NCC Group for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A race condition vulnerability was reported in IMController, a software component of Lenovo System Interface Foundation, prior to version 1.1.20.3 that could allow a local attacker to connect and interact with the IMController child process\u0027 named pipe."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-75210",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-75210"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update the IMController component of Lenovo System Interface Foundation to version 1.1.20.3. Full mitigation guidance can be found in LEN-75210."
}
],
"source": {
"advisory": "LEN-75210",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3922",
"datePublished": "2022-05-18T16:10:22.000Z",
"dateReserved": "2021-11-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:09:09.782Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8346 (GCVE-0-2020-8346)
Vulnerability from cvelistv5 – Published: 2020-09-15 14:20 – Updated: 2024-09-17 04:18
VLAI
Summary
A denial of service vulnerability was reported in the Lenovo Vantage component called Lenovo System Interface Foundation prior to version 1.1.19.5 that could allow configuration files to be written to non-standard locations.
Severity
5.5 (Medium)
CWE
- CWE-276 - Incorrect Default Permissions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | System Interface Foundation |
Affected:
unspecified , < 1.1.19.5
(custom)
|
Date Public
2020-09-15 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-38717"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.19.5",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Samet Bekmezci for reporting this issue."
}
],
"datePublic": "2020-09-15T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability was reported in the Lenovo Vantage component called Lenovo System Interface Foundation prior to version 1.1.19.5 that could allow configuration files to be written to non-standard locations."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-15T14:20:18.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-38717"
}
],
"solutions": [
{
"lang": "en",
"value": "To update Lenovo System Interface Foundation to version 1.1.19.5 or later, follow these steps: Update Lenovo Vantage to the latest version from the Microsoft Store. Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-38717",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-09-15T16:00:00.000Z",
"ID": "CVE-2020-8346",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.19.5"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Samet Bekmezci for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A denial of service vulnerability was reported in the Lenovo Vantage component called Lenovo System Interface Foundation prior to version 1.1.19.5 that could allow configuration files to be written to non-standard locations."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276 Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-38717",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-38717"
}
]
},
"solution": [
{
"lang": "en",
"value": "To update Lenovo System Interface Foundation to version 1.1.19.5 or later, follow these steps: Update Lenovo Vantage to the latest version from the Microsoft Store. Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-38717",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8346",
"datePublished": "2020-09-15T14:20:18.491Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-17T04:18:52.614Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8324 (GCVE-0-2020-8324)
Vulnerability from cvelistv5 – Published: 2020-04-14 21:05 – Updated: 2024-09-16 18:44
VLAI
Summary
A vulnerability was reported in LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation prior to version 1.2.184.31 that could allow unsigned DLL files to be executed.
Severity
5 (Medium)
CWE
- CWE-347 - Improper Verification of Cryptographic Signature
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation |
Affected:
unspecified , < 1.2.184.31
(custom)
|
Date Public
2020-04-14 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.363Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.2.184.31",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"datePublic": "2020-04-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation prior to version 1.2.184.31 that could allow unsigned DLL files to be executed."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347 Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-14T21:05:20.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"solutions": [
{
"lang": "en",
"value": "Update LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation to version 1.2.184.31. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
"ID": "CVE-2020-8324",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.2.184.31"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was reported in LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation prior to version 1.2.184.31 that could allow unsigned DLL files to be executed."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-347 Improper Verification of Cryptographic Signature"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update LenovoAppScenarioPluginSystem for Lenovo System Interface Foundation to version 1.2.184.31. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8324",
"datePublished": "2020-04-14T21:05:20.866Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:44:12.684Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8319 (GCVE-0-2020-8319)
Vulnerability from cvelistv5 – Published: 2020-04-14 21:05 – Updated: 2024-09-16 17:27
VLAI
Summary
A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges.
Severity
7.3 (High)
CWE
- Privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Lenovo System Interface Foundation |
Affected:
unspecified , < 1.1.19.3
(custom)
|
Date Public
2020-04-14 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "1.1.19.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"datePublic": "2020-04-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-14T21:05:20.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.19.3. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
"ID": "CVE-2020-8319",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.1.19.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.19.3. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8319",
"datePublished": "2020-04-14T21:05:20.446Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:27:40.189Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8318 (GCVE-0-2020-8318)
Vulnerability from cvelistv5 – Published: 2020-04-14 21:05 – Updated: 2024-09-16 22:56
VLAI
Summary
A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges.
Severity
7.3 (High)
CWE
- Privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | LenovoSystemUpdatePlugin for Lenovo System Interface Foundation |
Affected:
unspecified , < 2.0.0.92
(custom)
|
Date Public
2020-04-14 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.350Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "2.0.0.92",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"datePublic": "2020-04-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-14T21:05:19.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"solutions": [
{
"lang": "en",
"value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
"ID": "CVE-2020-8318",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "2.0.0.92"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92. To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8318",
"datePublished": "2020-04-14T21:05:20.039Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:56:31.781Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6189 (GCVE-0-2019-6189)
Vulnerability from cvelistv5 – Published: 2019-11-20 01:31 – Updated: 2024-09-16 20:16
VLAI
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL.
Severity
No CVSS data available.
CWE
- local privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/solutions/LEN-29198 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Lenovo System Interface Foundation |
Unknown:
unspecified , ≤ 1.1.18.3
(custom)
|
Date Public
2019-11-19 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:16:24.514Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThanOrEqual": "1.1.18.3",
"status": "unknown",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-11-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-20T01:31:14.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.8"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
"ID": "CVE-2019-6189",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "?\u003c=",
"version_value": "1.1.18.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.8"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/solutions/LEN-29198",
"refsource": "MISC",
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2019-6189",
"datePublished": "2019-11-20T01:31:14.196Z",
"dateReserved": "2019-01-11T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:16:34.199Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6186 (GCVE-0-2019-6186)
Vulnerability from cvelistv5 – Published: 2019-11-20 01:31 – Updated: 2024-09-16 17:23
VLAI
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user.
Severity
No CVSS data available.
CWE
- local privilege escalation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.lenovo.com/solutions/LEN-29198 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Lenovo System Interface Foundation |
Unknown:
unspecified , ≤ 1.1.18.3
(custom)
|
Date Public
2019-11-19 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:16:23.842Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Lenovo System Interface Foundation",
"vendor": "Lenovo",
"versions": [
{
"lessThanOrEqual": "1.1.18.3",
"status": "unknown",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-11-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local privilege escalation",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-20T01:31:13.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.8"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
"ID": "CVE-2019-6186",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Lenovo System Interface Foundation",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "?\u003c=",
"version_value": "1.1.18.3"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.8"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/solutions/LEN-29198",
"refsource": "MISC",
"url": "https://support.lenovo.com/solutions/LEN-29198"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
}
],
"source": {
"advisory": "LEN-29198",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2019-6186",
"datePublished": "2019-11-20T01:31:13.404Z",
"dateReserved": "2019-01-11T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:23:01.398Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-8223 (GCVE-0-2016-8223)
Vulnerability from cvelistv5 – Published: 2016-11-29 20:00 – Updated: 2024-08-06 02:13
VLAI
Summary
During an internal security review, Lenovo identified a local privilege escalation vulnerability in Lenovo System Interface Foundation software installed on some Windows 10 PCs where a user with local privileges could run arbitrary code with administrator level privileges.
Severity
No CVSS data available.
CWE
- Lenovo System Interface Foundation Privilege Escalation?
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/solutions/LEN_10150 | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/94597 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo Group Ltd. | All ThinkPad, ThinkCentre, ThinkStation and Lenovo-branded systems preloaded with the Windows 10 operating system, or any system running Lenovo Companion, Lenovo Settings, or Lenovo ID. |
Affected:
1.0.66.0 and earlier
|
Date Public
2016-11-17 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:13:21.875Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/solutions/LEN_10150"
},
{
"name": "94597",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/94597"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "All ThinkPad, ThinkCentre, ThinkStation and Lenovo-branded systems preloaded with the Windows 10 operating system, or any system running Lenovo Companion, Lenovo Settings, or Lenovo ID.",
"vendor": "Lenovo Group Ltd.",
"versions": [
{
"status": "affected",
"version": "1.0.66.0 and earlier"
}
]
}
],
"datePublic": "2016-11-17T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "During an internal security review, Lenovo identified a local privilege escalation vulnerability in Lenovo System Interface Foundation software installed on some Windows 10 PCs where a user with local privileges could run arbitrary code with administrator level privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Lenovo System Interface Foundation Privilege Escalation?",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-01T10:57:01.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.lenovo.com/us/en/solutions/LEN_10150"
},
{
"name": "94597",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/94597"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2016-8223",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "All ThinkPad, ThinkCentre, ThinkStation and Lenovo-branded systems preloaded with the Windows 10 operating system, or any system running Lenovo Companion, Lenovo Settings, or Lenovo ID.",
"version": {
"version_data": [
{
"version_value": "1.0.66.0 and earlier"
}
]
}
}
]
},
"vendor_name": "Lenovo Group Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "During an internal security review, Lenovo identified a local privilege escalation vulnerability in Lenovo System Interface Foundation software installed on some Windows 10 PCs where a user with local privileges could run arbitrary code with administrator level privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Lenovo System Interface Foundation Privilege Escalation?"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/solutions/LEN_10150",
"refsource": "CONFIRM",
"url": "https://support.lenovo.com/us/en/solutions/LEN_10150"
},
{
"name": "94597",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/94597"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2016-8223",
"datePublished": "2016-11-29T20:00:00.000Z",
"dateReserved": "2016-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-06T02:13:21.875Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}