1 vulnerability found for swr-300bg by seowonintech
VAR-201906-0700
Vulnerability from variot - Updated: 2024-11-23 21:37On Seowon Intech routers, there is a Command Injection vulnerability in diagnostic.cgi via shell metacharacters in the ping_ipaddr parameter. Seowon Intech The router contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Seowon Intech routers are router products of Seowon Intech Company in South Korea. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data. Attackers can exploit this vulnerability to execute illegal commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201906-0700",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "swr-300a",
"scope": "eq",
"trust": 1.0,
"vendor": "seowonintech",
"version": null
},
{
"model": "swr-300b",
"scope": "eq",
"trust": 1.0,
"vendor": "seowonintech",
"version": null
},
{
"model": "swr-300c",
"scope": "eq",
"trust": 1.0,
"vendor": "seowonintech",
"version": null
},
{
"model": "swr-300bg",
"scope": "eq",
"trust": 1.0,
"vendor": "seowonintech",
"version": null
},
{
"model": "swr-300a",
"scope": null,
"trust": 0.8,
"vendor": "seowon intech",
"version": null
},
{
"model": "swr-300b",
"scope": null,
"trust": 0.8,
"vendor": "seowon intech",
"version": null
},
{
"model": "swr-300bg",
"scope": null,
"trust": 0.8,
"vendor": "seowon intech",
"version": null
},
{
"model": "swr-300c",
"scope": null,
"trust": 0.8,
"vendor": "seowon intech",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:seowon_intech:swr-300a_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:seowon_intech:swr-300b_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:seowon_intech:swr-300bg_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:seowon_intech:swr-300c_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
}
]
},
"cve": "CVE-2016-10760",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2016-10760",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-89569",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2016-10760",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2016-10760",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2016-10760",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-201906-403",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-89569",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2016-10760",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-89569"
},
{
"db": "VULMON",
"id": "CVE-2016-10760"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-403"
},
{
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "On Seowon Intech routers, there is a Command Injection vulnerability in diagnostic.cgi via shell metacharacters in the ping_ipaddr parameter. Seowon Intech The router contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Seowon Intech routers are router products of Seowon Intech Company in South Korea. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data. Attackers can exploit this vulnerability to execute illegal commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-10760"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"db": "VULHUB",
"id": "VHN-89569"
},
{
"db": "VULMON",
"id": "CVE-2016-10760"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-10760",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2016-009354",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201906-403",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-89569",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2016-10760",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-89569"
},
{
"db": "VULMON",
"id": "CVE-2016-10760"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-403"
},
{
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"id": "VAR-201906-0700",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-89569"
}
],
"trust": 0.01
},
"last_update_date": "2024-11-23T21:37:14.176000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Mobile Router (SWR-300A\u3001SWR-300B\u3001SWR-300C)",
"trust": 0.8,
"url": "http://www.seowonintech.co.kr/en/product/detail.asp?num=130\u0026big_kind=B04\u0026middle_kind="
},
{
"title": "Mobile Router (SWR-300BG)",
"trust": 0.8,
"url": "http://www.seowonintech.co.kr/jp/product/detail.asp?num=143\u0026big_kind=B04\u0026middle_kind=B04_07"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-89569"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://ethical-hacker.org/en/seowonintech-remote-root/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-10760"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-10760"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/77.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-89569"
},
{
"db": "VULMON",
"id": "CVE-2016-10760"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-403"
},
{
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-89569"
},
{
"db": "VULMON",
"id": "CVE-2016-10760"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-403"
},
{
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-06-11T00:00:00",
"db": "VULHUB",
"id": "VHN-89569"
},
{
"date": "2019-06-11T00:00:00",
"db": "VULMON",
"id": "CVE-2016-10760"
},
{
"date": "2019-06-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"date": "2019-06-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-403"
},
{
"date": "2019-06-11T21:29:00.443000",
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-06-12T00:00:00",
"db": "VULHUB",
"id": "VHN-89569"
},
{
"date": "2019-06-12T00:00:00",
"db": "VULMON",
"id": "CVE-2016-10760"
},
{
"date": "2019-06-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-009354"
},
{
"date": "2019-06-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-403"
},
{
"date": "2024-11-21T02:44:41.013000",
"db": "NVD",
"id": "CVE-2016-10760"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-403"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Seowon Intech Command injection vulnerability in routers",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-009354"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-403"
}
],
"trust": 0.6
}
}