Search criteria
4 vulnerabilities found for superdome_flex_280_firmware by hpe
CVE-2022-37933 (GCVE-0-2022-37933)
Vulnerability from nvd – Published: 2023-01-03 18:31 – Updated: 2025-04-10 15:45
VLAI?
Summary
A potential security vulnerability has been identified in HPE Superdome Flex and Superdome Flex 280 servers. The vulnerability could be exploited to allow local unauthorized data injection. HPE has made the following software updates to resolve the vulnerability in HPE Superdome Flex firmware 3.60.50 and below and Superdome Flex 280 servers firmware 1.40.60 and below.
Severity ?
7.3 (High)
CWE
- n/a
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE Superdome Flex Server; HPE Superdome Flex 280 Server |
Affected:
Prior to 3.60.50; Prior to 1.40.60
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:37:42.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04400en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-37933",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-10T15:45:04.740841Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-10T15:45:08.304Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HPE Superdome Flex Server; HPE Superdome Flex 280 Server",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "Prior to 3.60.50; Prior to 1.40.60"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA potential security vulnerability has been identified in HPE Superdome Flex and Superdome Flex 280 servers. The vulnerability could be exploited to allow local unauthorized data injection. HPE has made the following software updates to resolve the vulnerability in HPE Superdome Flex firmware 3.60.50 and below and Superdome Flex 280 servers firmware 1.40.60 and below.\u003c/p\u003e"
}
],
"value": "A potential security vulnerability has been identified in HPE Superdome Flex and Superdome Flex 280 servers. The vulnerability could be exploited to allow local unauthorized data injection. HPE has made the following software updates to resolve the vulnerability in HPE Superdome Flex firmware 3.60.50 and below and Superdome Flex 280 servers firmware 1.40.60 and below.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-05T05:58:57.684Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04400en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2022-37933",
"datePublished": "2023-01-03T18:31:35.870Z",
"dateReserved": "2022-08-08T18:49:44.386Z",
"dateUpdated": "2025-04-10T15:45:08.304Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-26589 (GCVE-0-2021-26589)
Vulnerability from nvd – Published: 2021-10-19 14:10 – Updated: 2024-08-03 20:26
VLAI?
Summary
A potential security vulnerability has been identified in HPE Superdome Flex Servers. The vulnerability could be remotely exploited to allow Cross Site Scripting (XSS) because the Session Cookie is missing an HttpOnly Attribute. HPE has provided a firmware update to resolve the vulnerability in HPE Superdome Flex Servers.
Severity ?
No CVSS data available.
CWE
- remote cross-site scripting (xss)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE Superdome Flex Server |
Affected:
Prior to Version 3.40.106
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:26:25.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Superdome Flex Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Prior to Version 3.40.106"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential security vulnerability has been identified in HPE Superdome Flex Servers. The vulnerability could be remotely exploited to allow Cross Site Scripting (XSS) because the Session Cookie is missing an HttpOnly Attribute. HPE has provided a firmware update to resolve the vulnerability in HPE Superdome Flex Servers."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote cross-site scripting (xss)",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-19T14:10:18.000Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-26589",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Superdome Flex Server",
"version": {
"version_data": [
{
"version_value": "Prior to Version 3.40.106"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential security vulnerability has been identified in HPE Superdome Flex Servers. The vulnerability could be remotely exploited to allow Cross Site Scripting (XSS) because the Session Cookie is missing an HttpOnly Attribute. HPE has provided a firmware update to resolve the vulnerability in HPE Superdome Flex Servers."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote cross-site scripting (xss)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-26589",
"datePublished": "2021-10-19T14:10:18.000Z",
"dateReserved": "2021-02-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:26:25.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37933 (GCVE-0-2022-37933)
Vulnerability from cvelistv5 – Published: 2023-01-03 18:31 – Updated: 2025-04-10 15:45
VLAI?
Summary
A potential security vulnerability has been identified in HPE Superdome Flex and Superdome Flex 280 servers. The vulnerability could be exploited to allow local unauthorized data injection. HPE has made the following software updates to resolve the vulnerability in HPE Superdome Flex firmware 3.60.50 and below and Superdome Flex 280 servers firmware 1.40.60 and below.
Severity ?
7.3 (High)
CWE
- n/a
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE Superdome Flex Server; HPE Superdome Flex 280 Server |
Affected:
Prior to 3.60.50; Prior to 1.40.60
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:37:42.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04400en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-37933",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-10T15:45:04.740841Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-10T15:45:08.304Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HPE Superdome Flex Server; HPE Superdome Flex 280 Server",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "Prior to 3.60.50; Prior to 1.40.60"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA potential security vulnerability has been identified in HPE Superdome Flex and Superdome Flex 280 servers. The vulnerability could be exploited to allow local unauthorized data injection. HPE has made the following software updates to resolve the vulnerability in HPE Superdome Flex firmware 3.60.50 and below and Superdome Flex 280 servers firmware 1.40.60 and below.\u003c/p\u003e"
}
],
"value": "A potential security vulnerability has been identified in HPE Superdome Flex and Superdome Flex 280 servers. The vulnerability could be exploited to allow local unauthorized data injection. HPE has made the following software updates to resolve the vulnerability in HPE Superdome Flex firmware 3.60.50 and below and Superdome Flex 280 servers firmware 1.40.60 and below.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-05T05:58:57.684Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04400en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2022-37933",
"datePublished": "2023-01-03T18:31:35.870Z",
"dateReserved": "2022-08-08T18:49:44.386Z",
"dateUpdated": "2025-04-10T15:45:08.304Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-26589 (GCVE-0-2021-26589)
Vulnerability from cvelistv5 – Published: 2021-10-19 14:10 – Updated: 2024-08-03 20:26
VLAI?
Summary
A potential security vulnerability has been identified in HPE Superdome Flex Servers. The vulnerability could be remotely exploited to allow Cross Site Scripting (XSS) because the Session Cookie is missing an HttpOnly Attribute. HPE has provided a firmware update to resolve the vulnerability in HPE Superdome Flex Servers.
Severity ?
No CVSS data available.
CWE
- remote cross-site scripting (xss)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE Superdome Flex Server |
Affected:
Prior to Version 3.40.106
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:26:25.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Superdome Flex Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Prior to Version 3.40.106"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential security vulnerability has been identified in HPE Superdome Flex Servers. The vulnerability could be remotely exploited to allow Cross Site Scripting (XSS) because the Session Cookie is missing an HttpOnly Attribute. HPE has provided a firmware update to resolve the vulnerability in HPE Superdome Flex Servers."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote cross-site scripting (xss)",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-19T14:10:18.000Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-26589",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Superdome Flex Server",
"version": {
"version_data": [
{
"version_value": "Prior to Version 3.40.106"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential security vulnerability has been identified in HPE Superdome Flex Servers. The vulnerability could be remotely exploited to allow Cross Site Scripting (XSS) because the Session Cookie is missing an HttpOnly Attribute. HPE has provided a firmware update to resolve the vulnerability in HPE Superdome Flex Servers."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote cross-site scripting (xss)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04199en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-26589",
"datePublished": "2021-10-19T14:10:18.000Z",
"dateReserved": "2021-02-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:26:25.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}