Search criteria
8 vulnerabilities found for ssd_dc_p4610_firmware by intel
CVE-2020-12311 (GCVE-0-2020-12311)
Vulnerability from nvd – Published: 2020-11-12 17:58 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access.
Severity ?
No CVSS data available.
CWE
- information disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) Client SSDs and some Intel(R) Data Center SSDs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:50.594Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T17:58:42",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12311",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12311",
"datePublished": "2020-11-12T17:58:43",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:50.594Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12310 (GCVE-0-2020-12310)
Vulnerability from nvd – Published: 2020-11-12 17:58 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access.
Severity ?
No CVSS data available.
CWE
- information disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) Client SSDs and some Intel(R) Data Center SSDs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:51.351Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T17:58:35",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12310",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12310",
"datePublished": "2020-11-12T17:58:35",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:51.351Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12309 (GCVE-0-2020-12309)
Vulnerability from nvd – Published: 2020-11-12 17:58 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insufficiently protected credentialsin subsystem in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access.
Severity ?
No CVSS data available.
CWE
- information disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) Client SSDs and some Intel(R) Data Center SSDs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:51.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficiently protected credentialsin subsystem in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T17:58:25",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12309",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficiently protected credentialsin subsystem in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12309",
"datePublished": "2020-11-12T17:58:25",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:51.255Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-0527 (GCVE-0-2020-0527)
Vulnerability from nvd – Published: 2020-06-15 13:52 – Updated: 2024-08-04 06:02
VLAI?
Summary
Insufficient control flow management in firmware for some Intel(R) Data Center SSDs may allow a privileged user to potentially enable information disclosure via local access.
Severity ?
No CVSS data available.
CWE
- Information Disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) SSD |
Affected:
See provided reference
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:02:52.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) SSD",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See provided reference"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow management in firmware for some Intel(R) Data Center SSDs may allow a privileged user to potentially enable information disclosure via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information Disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-15T13:52:05",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-0527",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) SSD",
"version": {
"version_data": [
{
"version_value": "See provided reference"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient control flow management in firmware for some Intel(R) Data Center SSDs may allow a privileged user to potentially enable information disclosure via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-0527",
"datePublished": "2020-06-15T13:52:05",
"dateReserved": "2019-10-28T00:00:00",
"dateUpdated": "2024-08-04T06:02:52.293Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12311 (GCVE-0-2020-12311)
Vulnerability from cvelistv5 – Published: 2020-11-12 17:58 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access.
Severity ?
No CVSS data available.
CWE
- information disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) Client SSDs and some Intel(R) Data Center SSDs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:50.594Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T17:58:42",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12311",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12311",
"datePublished": "2020-11-12T17:58:43",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:50.594Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12310 (GCVE-0-2020-12310)
Vulnerability from cvelistv5 – Published: 2020-11-12 17:58 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access.
Severity ?
No CVSS data available.
CWE
- information disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) Client SSDs and some Intel(R) Data Center SSDs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:51.351Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T17:58:35",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12310",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient control flow managementin firmware in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12310",
"datePublished": "2020-11-12T17:58:35",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:51.351Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12309 (GCVE-0-2020-12309)
Vulnerability from cvelistv5 – Published: 2020-11-12 17:58 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insufficiently protected credentialsin subsystem in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access.
Severity ?
No CVSS data available.
CWE
- information disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) Client SSDs and some Intel(R) Data Center SSDs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:51.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficiently protected credentialsin subsystem in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T17:58:25",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12309",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Client SSDs and some Intel(R) Data Center SSDs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficiently protected credentialsin subsystem in some Intel(R) Client SSDs and some Intel(R) Data Center SSDs may allow an unauthenticated user to potentially enable information disclosure via physical access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00362"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12309",
"datePublished": "2020-11-12T17:58:25",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:51.255Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-0527 (GCVE-0-2020-0527)
Vulnerability from cvelistv5 – Published: 2020-06-15 13:52 – Updated: 2024-08-04 06:02
VLAI?
Summary
Insufficient control flow management in firmware for some Intel(R) Data Center SSDs may allow a privileged user to potentially enable information disclosure via local access.
Severity ?
No CVSS data available.
CWE
- Information Disclosure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) SSD |
Affected:
See provided reference
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:02:52.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) SSD",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See provided reference"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow management in firmware for some Intel(R) Data Center SSDs may allow a privileged user to potentially enable information disclosure via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information Disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-15T13:52:05",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-0527",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) SSD",
"version": {
"version_data": [
{
"version_value": "See provided reference"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient control flow management in firmware for some Intel(R) Data Center SSDs may allow a privileged user to potentially enable information disclosure via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00266.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-0527",
"datePublished": "2020-06-15T13:52:05",
"dateReserved": "2019-10-28T00:00:00",
"dateUpdated": "2024-08-04T06:02:52.293Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",