Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for solar-log_500_firmware by bkw

    CVE-2021-34544 (GCVE-0-2021-34544)

    Vulnerability from nvd – Published: 2021-12-07 20:41 – Updated: 2024-11-11 23:00
    VLAI
    Summary
    An issue was discovered in Solar-Log 500 before 2.8.2 Build 52 23.04.2013. In /export.html, email.html, and sms.html, cleartext passwords are stored. This may allow sensitive information to be read by someone with access to the device. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.389Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.solar-log.com/en/support/firmware/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://drive.google.com/file/d/1N8Ch1UGNcoocUaPhOe_1mAECOe5kr4pt/view?usp=sharing"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/49987"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Solar-Log 500 before 2.8.2 Build 52 23.04.2013. In /export.html, email.html, and sms.html, cleartext passwords are stored. This may allow sensitive information to be read by someone with access to the device. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-11T23:00:23.843Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.solar-log.com/en/support/firmware/"
            },
            {
              "url": "https://drive.google.com/file/d/1N8Ch1UGNcoocUaPhOe_1mAECOe5kr4pt/view?usp=sharing"
            },
            {
              "url": "https://www.exploit-db.com/exploits/49987"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-34544",
        "datePublished": "2021-12-07T20:41:21.000Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-11-11T23:00:23.843Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34543 (GCVE-0-2021-34543)

    Vulnerability from nvd – Published: 2021-12-07 20:39 – Updated: 2024-11-11 23:01
    VLAI
    Summary
    The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.391Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://drive.google.com/file/d/1z1TaANlDyX4SOP2vjNzkPQI3nETL9kZM/view?usp=sharing"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.solar-log.com/en/support/firmware/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/49986"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-11T23:01:45.243Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://drive.google.com/file/d/1z1TaANlDyX4SOP2vjNzkPQI3nETL9kZM/view?usp=sharing"
            },
            {
              "url": "https://www.solar-log.com/en/support/firmware/"
            },
            {
              "url": "https://www.exploit-db.com/exploits/49986"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-34543",
        "datePublished": "2021-12-07T20:39:05.000Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-11-11T23:01:45.243Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34544 (GCVE-0-2021-34544)

    Vulnerability from cvelistv5 – Published: 2021-12-07 20:41 – Updated: 2024-11-11 23:00
    VLAI
    Summary
    An issue was discovered in Solar-Log 500 before 2.8.2 Build 52 23.04.2013. In /export.html, email.html, and sms.html, cleartext passwords are stored. This may allow sensitive information to be read by someone with access to the device. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.389Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.solar-log.com/en/support/firmware/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://drive.google.com/file/d/1N8Ch1UGNcoocUaPhOe_1mAECOe5kr4pt/view?usp=sharing"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/49987"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Solar-Log 500 before 2.8.2 Build 52 23.04.2013. In /export.html, email.html, and sms.html, cleartext passwords are stored. This may allow sensitive information to be read by someone with access to the device. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-11T23:00:23.843Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.solar-log.com/en/support/firmware/"
            },
            {
              "url": "https://drive.google.com/file/d/1N8Ch1UGNcoocUaPhOe_1mAECOe5kr4pt/view?usp=sharing"
            },
            {
              "url": "https://www.exploit-db.com/exploits/49987"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-34544",
        "datePublished": "2021-12-07T20:41:21.000Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-11-11T23:00:23.843Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34543 (GCVE-0-2021-34543)

    Vulnerability from cvelistv5 – Published: 2021-12-07 20:39 – Updated: 2024-11-11 23:01
    VLAI
    Summary
    The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.391Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://drive.google.com/file/d/1z1TaANlDyX4SOP2vjNzkPQI3nETL9kZM/view?usp=sharing"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.solar-log.com/en/support/firmware/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/49986"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-11T23:01:45.243Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://drive.google.com/file/d/1z1TaANlDyX4SOP2vjNzkPQI3nETL9kZM/view?usp=sharing"
            },
            {
              "url": "https://www.solar-log.com/en/support/firmware/"
            },
            {
              "url": "https://www.exploit-db.com/exploits/49986"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-34543",
        "datePublished": "2021-12-07T20:39:05.000Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-11-11T23:01:45.243Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }