Search
Find a vulnerability
Search criteria
21 vulnerabilities found for smartpower_web by gruparge
FKIE_CVE-2022-45089
Vulnerability from fkie_nvd - Published: 2023-02-12 04:15 - Updated: 2026-11-10 12:10
Severity
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.
This issue affects Smartpower Web: before 23.01.01.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| gruparge | smartpower_web | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "iletisim@usom.gov.tr"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
"versionEndExcluding": "23.01.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
},
{
"lang": "es",
"value": "Vulnerabilidad de validaci\u00f3n de entrada inadecuada en Group Arge Energy and Control Systems Smartpower Web permite inyecci\u00f3n SQL.\n\nEste problema afecta a Smartpower Web: anterior a 23.01.01."
}
],
"id": "CVE-2022-45089",
"lastModified": "2026-11-10T12:10:00.177",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-45089",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:47:47.485436Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-12T04:15:16.717",
"references": [
{
"source": "iletisim@usom.gov.tr",
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
},
{
"source": "iletisim@usom.gov.tr",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"sourceIdentifier": "iletisim@usom.gov.tr",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-45091
Vulnerability from fkie_nvd - Published: 2023-02-12 04:15 - Updated: 2026-11-10 12:10
Severity
5.4 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
5.4 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
5.4 (Medium) - CVSS:3.1/
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).
This issue affects Smartpower Web: before 23.01.01.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| gruparge | smartpower_web | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "iletisim@usom.gov.tr"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
"versionEndExcluding": "23.01.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\n\nThis issue affects Smartpower Web: before 23.01.01."
},
{
"lang": "es",
"value": "Neutralizaci\u00f3n Incorrecta de la Entrada Durante la Generaci\u00f3n de P\u00e1ginas Web (\u2019cross-site scripting\u2019) vulnerabilidad en Group Arge Energy and Control Systems Smartpower Web permite Cross-Site Scripting (XSS).\n\nEste problema afecta a Smartpower Web: antes de 23.01.01."
}
],
"id": "CVE-2022-45091",
"lastModified": "2026-11-10T12:10:00.177",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-45091",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:11:41.039766Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-12T04:15:16.860",
"references": [
{
"source": "iletisim@usom.gov.tr",
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
},
{
"source": "iletisim@usom.gov.tr",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"sourceIdentifier": "iletisim@usom.gov.tr",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-45085
Vulnerability from fkie_nvd - Published: 2023-02-12 04:15 - Updated: 2026-11-10 12:10
Severity
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/
Summary
Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.
This issue affects Smartpower Web: before 23.01.01.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| gruparge | smartpower_web | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "iletisim@usom.gov.tr"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
"versionEndExcluding": "23.01.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.\n\nThis issue affects Smartpower Web: before 23.01.01."
},
{
"lang": "es",
"value": "Vulnerabilidad de Server-Side Request Forgery (SSRF) en Group Arge Energy and Control Systems Smartpower Web permite: Server-Side Request Forgery.\n\nEste problema afecta a Smartpower Web: antes de 23.01.01."
}
],
"id": "CVE-2022-45085",
"lastModified": "2026-11-10T12:10:00.177",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-45085",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:57:20.371683Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-12T04:15:16.397",
"references": [
{
"source": "iletisim@usom.gov.tr",
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
},
{
"source": "iletisim@usom.gov.tr",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"sourceIdentifier": "iletisim@usom.gov.tr",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-918"
}
],
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-918"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-45088
Vulnerability from fkie_nvd - Published: 2023-02-12 04:15 - Updated: 2026-11-10 12:10
Severity
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.
This issue affects Smartpower Web: before 23.01.01.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| gruparge | smartpower_web | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "iletisim@usom.gov.tr"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
"versionEndExcluding": "23.01.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.\n\nThis issue affects Smartpower Web: before 23.01.01."
},
{
"lang": "es",
"value": "Vulnerabilidad de validaci\u00f3n de entrada incorrecta en Group Arge Energy and Control Systems Smartpower Web permite inclusi\u00f3n local de ficheros PHP.\n\nEste problema afecta a Smartpower Web: anterior a 23.01.01."
}
],
"id": "CVE-2022-45088",
"lastModified": "2026-11-10T12:10:00.177",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-45088",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:48:08.787560Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-12T04:15:16.640",
"references": [
{
"source": "iletisim@usom.gov.tr",
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
},
{
"source": "iletisim@usom.gov.tr",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"sourceIdentifier": "iletisim@usom.gov.tr",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-45090
Vulnerability from fkie_nvd - Published: 2023-02-12 04:15 - Updated: 2026-11-10 12:10
Severity
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.
This issue affects Smartpower Web: before 23.01.01.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| gruparge | smartpower_web | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "iletisim@usom.gov.tr"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
"versionEndExcluding": "23.01.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
},
{
"lang": "es",
"value": "Vulnerabilidad de validaci\u00f3n de entrada inadecuada en Group Arge Energy and Control Systems Smartpower Web permite inyecci\u00f3n SQL.\n\nEste problema afecta a Smartpower Web: antes de 23.01.01."
}
],
"id": "CVE-2022-45090",
"lastModified": "2026-11-10T12:10:00.177",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-45090",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:12:09.543713Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-12T04:15:16.790",
"references": [
{
"source": "iletisim@usom.gov.tr",
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
},
{
"source": "iletisim@usom.gov.tr",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"sourceIdentifier": "iletisim@usom.gov.tr",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-45087
Vulnerability from fkie_nvd - Published: 2023-02-12 04:15 - Updated: 2026-06-17 05:09
Severity
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| gruparge | smartpower_web | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "iletisim@usom.gov.tr"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
"versionEndExcluding": "23.01.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
}
],
"id": "CVE-2022-45087",
"lastModified": "2026-06-17T05:09:19.913",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-45087",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:52:32.590384Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-12T04:15:16.567",
"references": [
{
"source": "iletisim@usom.gov.tr",
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
},
{
"source": "iletisim@usom.gov.tr",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"sourceIdentifier": "iletisim@usom.gov.tr",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-45086
Vulnerability from fkie_nvd - Published: 2023-02-12 04:15 - Updated: 2026-06-17 05:09
Severity
5.4 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
5.4 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
5.4 (Medium) - CVSS:3.1/
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| gruparge | smartpower_web | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "iletisim@usom.gov.tr"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
"versionEndExcluding": "23.01.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
}
],
"id": "CVE-2022-45086",
"lastModified": "2026-06-17T05:09:19.783",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-45086",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:53:26.674714Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-12T04:15:16.487",
"references": [
{
"source": "iletisim@usom.gov.tr",
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
},
{
"source": "iletisim@usom.gov.tr",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"sourceIdentifier": "iletisim@usom.gov.tr",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "iletisim@usom.gov.tr",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2022-45091 (GCVE-0-2022-45091)
Vulnerability from nvd – Published: 2023-02-08 19:27 – Updated: 2026-05-18 14:39
VLAI
EPSS
VEX
Title
Cross-site Scripting in Smartpower Web
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).
This issue affects Smartpower Web: before 23.01.01.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:11 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45091",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:11:41.039766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:11:45.416Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:39:27.356Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Cross-site Scripting in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45091",
"datePublished": "2023-02-08T19:27:17.083Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:39:27.356Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45090 (GCVE-0-2022-45090)
Vulnerability from nvd – Published: 2023-02-08 19:21 – Updated: 2026-05-18 14:37
VLAI
EPSS
VEX
Title
SQL Injection in Smartpower Web
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.
This issue affects Smartpower Web: before 23.01.01.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:12 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.531Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45090",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:12:09.543713Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:38:34.511Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:37:25.895Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "SQL Injection in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45090",
"datePublished": "2023-02-08T19:21:32.092Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:37:25.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45089 (GCVE-0-2022-45089)
Vulnerability from nvd – Published: 2023-02-08 19:18 – Updated: 2026-05-18 14:34
VLAI
EPSS
VEX
Title
SQL Injection in Smartpower Web
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.
This issue affects Smartpower Web: before 23.01.01.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:47 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45089",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:47:47.485436Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:47:53.654Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:34:40.076Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "SQL Injection in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45089",
"datePublished": "2023-02-08T19:18:52.229Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:34:40.076Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45088 (GCVE-0-2022-45088)
Vulnerability from nvd – Published: 2023-02-08 18:50 – Updated: 2026-05-18 14:29
VLAI
EPSS
VEX
Title
Local File Inclusion in Smartpower Web
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.
This issue affects Smartpower Web: before 23.01.01.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:48 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.505Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45088",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:48:08.787560Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:48:12.760Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-252",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-252 PHP Local File Inclusion"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:29:59.468Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Local File Inclusion in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45088",
"datePublished": "2023-02-08T18:50:07.000Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:29:59.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45087 (GCVE-0-2022-45087)
Vulnerability from nvd – Published: 2023-02-08 18:46 – Updated: 2026-05-18 14:28
VLAI
EPSS
VEX
Title
Cross-site Scripting in Smartpower Web
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
Severity
6.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-25 13:52 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.477Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45087",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:52:32.590384Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:52:39.650Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u0026nbsp;\u003cspan\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/span\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:28:07.274Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Cross-site Scripting in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45087",
"datePublished": "2023-02-08T18:46:13.951Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:28:07.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45086 (GCVE-0-2022-45086)
Vulnerability from nvd – Published: 2023-02-08 18:27 – Updated: 2026-05-18 14:42
VLAI
EPSS
VEX
Title
Cross-site Scripting in Smartpower Web
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-25 13:53 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.527Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:53:26.674714Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:53:35.194Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u0026nbsp;\u003cspan\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/span\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:42:36.302Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Cross-site Scripting in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45086",
"datePublished": "2023-02-08T18:27:15.888Z",
"dateReserved": "2022-11-09T13:35:23.469Z",
"dateUpdated": "2026-05-18T14:42:36.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45085 (GCVE-0-2022-45085)
Vulnerability from nvd – Published: 2023-02-08 14:48 – Updated: 2026-05-18 14:40
VLAI
EPSS
VEX
Title
Server-Side Request Forgery in Smartpower Web
Summary
Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.
This issue affects Smartpower Web: before 23.01.01.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-25 13:57 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45085",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:57:20.371683Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:57:29.774Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-664",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-664 Server Side Request Forgery"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:40:49.577Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Server-Side Request Forgery in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45085",
"datePublished": "2023-02-08T14:48:27.782Z",
"dateReserved": "2022-11-09T13:35:23.469Z",
"dateUpdated": "2026-05-18T14:40:49.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45091 (GCVE-0-2022-45091)
Vulnerability from cvelistv5 – Published: 2023-02-08 19:27 – Updated: 2026-05-18 14:39
VLAI
EPSS
VEX
Title
Cross-site Scripting in Smartpower Web
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).
This issue affects Smartpower Web: before 23.01.01.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:11 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45091",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:11:41.039766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:11:45.416Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:39:27.356Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Cross-site Scripting in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45091",
"datePublished": "2023-02-08T19:27:17.083Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:39:27.356Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45090 (GCVE-0-2022-45090)
Vulnerability from cvelistv5 – Published: 2023-02-08 19:21 – Updated: 2026-05-18 14:37
VLAI
EPSS
VEX
Title
SQL Injection in Smartpower Web
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.
This issue affects Smartpower Web: before 23.01.01.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:12 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.531Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45090",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:12:09.543713Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:38:34.511Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:37:25.895Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "SQL Injection in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45090",
"datePublished": "2023-02-08T19:21:32.092Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:37:25.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45089 (GCVE-0-2022-45089)
Vulnerability from cvelistv5 – Published: 2023-02-08 19:18 – Updated: 2026-05-18 14:34
VLAI
EPSS
VEX
Title
SQL Injection in Smartpower Web
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.
This issue affects Smartpower Web: before 23.01.01.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:47 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45089",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:47:47.485436Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:47:53.654Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:34:40.076Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "SQL Injection in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45089",
"datePublished": "2023-02-08T19:18:52.229Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:34:40.076Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45088 (GCVE-0-2022-45088)
Vulnerability from cvelistv5 – Published: 2023-02-08 18:50 – Updated: 2026-05-18 14:29
VLAI
EPSS
VEX
Title
Local File Inclusion in Smartpower Web
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.
This issue affects Smartpower Web: before 23.01.01.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:48 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.505Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45088",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-24T19:48:08.787560Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T19:48:12.760Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-252",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-252 PHP Local File Inclusion"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:29:59.468Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Local File Inclusion in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45088",
"datePublished": "2023-02-08T18:50:07.000Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:29:59.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45087 (GCVE-0-2022-45087)
Vulnerability from cvelistv5 – Published: 2023-02-08 18:46 – Updated: 2026-05-18 14:28
VLAI
EPSS
VEX
Title
Cross-site Scripting in Smartpower Web
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
Severity
6.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-25 13:52 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.477Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45087",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:52:32.590384Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:52:39.650Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u0026nbsp;\u003cspan\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/span\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:28:07.274Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Cross-site Scripting in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45087",
"datePublished": "2023-02-08T18:46:13.951Z",
"dateReserved": "2022-11-09T13:35:23.470Z",
"dateUpdated": "2026-05-18T14:28:07.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45086 (GCVE-0-2022-45086)
Vulnerability from cvelistv5 – Published: 2023-02-08 18:27 – Updated: 2026-05-18 14:42
VLAI
EPSS
VEX
Title
Cross-site Scripting in Smartpower Web
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-25 13:53 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.527Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:53:26.674714Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:53:35.194Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u0026nbsp;\u003cspan\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/span\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:42:36.302Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE ID reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Cross-site Scripting in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45086",
"datePublished": "2023-02-08T18:27:15.888Z",
"dateReserved": "2022-11-09T13:35:23.469Z",
"dateUpdated": "2026-05-18T14:42:36.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45085 (GCVE-0-2022-45085)
Vulnerability from cvelistv5 – Published: 2023-02-08 14:48 – Updated: 2026-05-18 14:40
VLAI
EPSS
VEX
Title
Server-Side Request Forgery in Smartpower Web
Summary
Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.
This issue affects Smartpower Web: before 23.01.01.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-25 13:57 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-23-0066 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Group Arge Energy and Control Systems | Smartpower Web |
Affected:
0 , < 23.01.01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45085",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:57:20.371683Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:57:29.774Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower Web",
"vendor": "Group Arge Energy and Control Systems",
"versions": [
{
"lessThan": "23.01.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Furkan KUTLUCA"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
}
],
"value": "Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.\n\nThis issue affects Smartpower Web: before 23.01.01."
}
],
"impacts": [
{
"capecId": "CAPEC-664",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-664 Server Side Request Forgery"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T14:40:49.577Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update the software to \u0026gt;= 23.01.01"
}
],
"value": "Update the software to \u003e= 23.01.01"
}
],
"source": {
"advisory": "TR-23-0066",
"defect": [
"TR-23-0066"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2022-11-08T14:44:00.000Z",
"value": "Vulnerability detected"
},
{
"lang": "en",
"time": "2022-11-09T10:35:00.000Z",
"value": "CVE reservation"
},
{
"lang": "en",
"time": "2022-11-09T12:00:00.000Z",
"value": "Vendor informed"
},
{
"lang": "en",
"time": "2023-01-01T10:00:00.000Z",
"value": "Patch published by vendor"
},
{
"lang": "en",
"time": "2023-02-08T13:00:00.000Z",
"value": "Government advisory published"
},
{
"lang": "en",
"time": "2023-02-08T14:50:00.000Z",
"value": "CVE published"
}
],
"title": "Server-Side Request Forgery in Smartpower Web",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2022-45085",
"datePublished": "2023-02-08T14:48:27.782Z",
"dateReserved": "2022-11-09T13:35:23.469Z",
"dateUpdated": "2026-05-18T14:40:49.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}