CVE-2025-40751 (GCVE-0-2025-40751)
Vulnerability from nvd – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.3). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-12 13:30 UTC
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.3
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40751",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T13:30:25.441333Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-13T20:18:34.434Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V3.3). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522: Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:17:06.481Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-707630.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40751",
"datePublished": "2025-08-12T11:17:06.481Z",
"dateReserved": "2025-04-16T08:39:30.031Z",
"dateUpdated": "2025-08-13T20:18:34.434Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40746 (GCVE-0-2025-40746)
Vulnerability from nvd – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not properly validate input for a backup script. This could allow an authenticated remote attacker with high privileges in the application to execute arbitrary code with 'NT Authority/SYSTEM' privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-12 13:31 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T13:31:40.234230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-13T20:18:41.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V3.2). Affected products do not properly validate input for a backup script. This could allow an authenticated remote attacker with high privileges in the application to execute arbitrary code with \u0027NT Authority/SYSTEM\u0027 privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:17:05.245Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-493787.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40746",
"datePublished": "2025-08-12T11:17:05.245Z",
"dateReserved": "2025-04-16T08:39:30.030Z",
"dateUpdated": "2025-08-13T20:18:41.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30034 (GCVE-0-2025-30034)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 20:09
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.3). Affected devices do not properly validate input sent to its listening port on the local loopback interface. This could allow an unauthenticated local attacker to cause a denial of service condition.
Severity
6.2 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-12 20:08 UTC
CWE
- CWE-617 - Reachable Assertion
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.3
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30034",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T20:08:52.101384Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T20:09:02.333Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V3.3). Affected devices do not properly validate input sent to its listening port on the local loopback interface. This could allow an unauthenticated local attacker to cause a denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617: Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:58.223Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-707630.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-30034",
"datePublished": "2025-08-12T11:16:58.223Z",
"dateReserved": "2025-03-14T13:48:46.135Z",
"dateUpdated": "2025-08-12T20:09:02.333Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33583 (GCVE-0-2024-33583)
Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:39 UTC
CWE
- CWE-912 - Hidden Functionality
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33583",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:39:01.289567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:50:40.620Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:04.133Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:47.219Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33583",
"datePublished": "2024-05-14T10:03:06.924Z",
"dateReserved": "2024-04-24T14:47:52.265Z",
"dateUpdated": "2024-08-02T02:36:04.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33499 (GCVE-0-2024-33499)
Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:34 UTC
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:34:44.477523Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:49:58.318Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:03.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:44.706Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33499",
"datePublished": "2024-05-14T10:03:04.171Z",
"dateReserved": "2024-04-23T11:08:04.355Z",
"dateUpdated": "2024-08-02T02:36:03.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33498 (GCVE-0-2024-33498)
Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:39 UTC
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:39:37.190207Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:49:45.592Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:02.815Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:43.420Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33498",
"datePublished": "2024-05-14T10:03:02.675Z",
"dateReserved": "2024-04-23T11:08:04.355Z",
"dateUpdated": "2024-08-02T02:36:02.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33497 (GCVE-0-2024-33497)
Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:40 UTC
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33497",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:40:22.212279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:49:29.917Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:02.830Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522: Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:42.140Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33497",
"datePublished": "2024-05-14T10:03:01.146Z",
"dateReserved": "2024-04-23T11:08:04.355Z",
"dateUpdated": "2024-08-02T02:36:02.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33496 (GCVE-0-2024-33496)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:40 UTC
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33496",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:40:50.424175Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:43:25.590Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:03.992Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522: Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:40.834Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33496",
"datePublished": "2024-05-14T10:02:59.612Z",
"dateReserved": "2024-04-23T11:08:04.354Z",
"dateUpdated": "2024-08-02T02:36:03.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33495 (GCVE-0-2024-33495)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application does not properly limit the size of specific logs. This could allow an unauthenticated remote attacker to exhaust system resources by creating a great number of log entries which could potentially lead to a denial of service condition. A successful exploitation requires the attacker to have access to specific SIMATIC RTLS Locating Manager Clients in the deployment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:41 UTC
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33495",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:41:28.915132Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:43:01.644Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:03.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The affected application does not properly limit the size of specific logs. This could allow an unauthenticated remote attacker to exhaust system resources by creating a great number of log entries which could potentially lead to a denial of service condition. A successful exploitation requires the attacker to have access to specific SIMATIC RTLS Locating Manager Clients in the deployment."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:39.548Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33495",
"datePublished": "2024-05-14T10:02:58.115Z",
"dateReserved": "2024-04-23T11:08:04.354Z",
"dateUpdated": "2024-08-02T02:36:03.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33494 (GCVE-0-2024-33494)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:38 UTC
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33494",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:38:06.838394Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:42:46.441Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:02.830Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:38.261Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33494",
"datePublished": "2024-05-14T10:02:56.636Z",
"dateReserved": "2024-04-23T11:08:04.354Z",
"dateUpdated": "2024-08-02T02:36:02.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30209 (GCVE-0-2024-30209)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM).
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-23 18:38 UTC
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30209",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T18:38:46.466956Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T18:38:49.741Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.337Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM)."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:33.239Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30209",
"datePublished": "2024-05-14T10:02:22.448Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.337Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30208 (GCVE-0-2024-30208)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The "DBTest" tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:47 UTC
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30208",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:47:49.178921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T16:12:55.825Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.408Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The \"DBTest\" tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:31.948Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30208",
"datePublished": "2024-05-14T10:02:20.970Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30207 (GCVE-0-2024-30207)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.
A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 15:39 UTC
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
-
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "-"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30207",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T15:39:49.414605Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:38:28.995Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.426Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.\r\nA successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321: Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:30.666Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30207",
"datePublished": "2024-05-14T10:02:19.474Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.426Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30206 (GCVE-0-2024-30206)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Clients do not properly check the integrity of update files. This could allow an unauthenticated remote attacker to alter update files in transit and trick an authorized user into installing malicious code.
A successful exploit requires the attacker to be able to modify the communication between server and client on the network.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-30 19:35 UTC
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30206",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-30T19:35:20.108365Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:38:31.863Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected SIMATIC RTLS Locating Manager Clients do not properly check the integrity of update files. This could allow an unauthenticated remote attacker to alter update files in transit and trick an authorized user into installing malicious code. \r\nA successful exploit requires the attacker to be able to modify the communication between server and client on the network."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:29.386Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30206",
"datePublished": "2024-05-14T10:02:17.971Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10054 (GCVE-0-2020-10054)
Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2024-08-04 10:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the application service.
Severity
No CVSS data available.
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
All versions < V2.12
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:50:57.460Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.12"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the application service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-09T11:31:38.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-10054",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC RTLS Locating Manager",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.12"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the application service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-10054",
"datePublished": "2021-11-09T11:31:38.000Z",
"dateReserved": "2020-03-04T00:00:00.000Z",
"dateUpdated": "2024-08-04T10:50:57.460Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10053 (GCVE-0-2020-10053)
Vulnerability from nvd – Published: 2021-11-09 11:31 – Updated: 2024-08-04 10:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.
Severity
No CVSS data available.
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
All versions < V2.12
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:50:57.831Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.12"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-09T11:31:37.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-10053",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC RTLS Locating Manager",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.12"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312: Cleartext Storage of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-10053",
"datePublished": "2021-11-09T11:31:37.000Z",
"dateReserved": "2020-03-04T00:00:00.000Z",
"dateUpdated": "2024-08-04T10:50:57.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40751 (GCVE-0-2025-40751)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.3). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-12 13:30 UTC
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.3
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40751",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T13:30:25.441333Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-13T20:18:34.434Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V3.3). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522: Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:17:06.481Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-707630.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40751",
"datePublished": "2025-08-12T11:17:06.481Z",
"dateReserved": "2025-04-16T08:39:30.031Z",
"dateUpdated": "2025-08-13T20:18:34.434Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40746 (GCVE-0-2025-40746)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:17 – Updated: 2025-08-13 20:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not properly validate input for a backup script. This could allow an authenticated remote attacker with high privileges in the application to execute arbitrary code with 'NT Authority/SYSTEM' privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-12 13:31 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T13:31:40.234230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-13T20:18:41.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V3.2). Affected products do not properly validate input for a backup script. This could allow an authenticated remote attacker with high privileges in the application to execute arbitrary code with \u0027NT Authority/SYSTEM\u0027 privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:17:05.245Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-493787.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40746",
"datePublished": "2025-08-12T11:17:05.245Z",
"dateReserved": "2025-04-16T08:39:30.030Z",
"dateUpdated": "2025-08-13T20:18:41.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30034 (GCVE-0-2025-30034)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 20:09
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.3). Affected devices do not properly validate input sent to its listening port on the local loopback interface. This could allow an unauthenticated local attacker to cause a denial of service condition.
Severity
6.2 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-12 20:08 UTC
CWE
- CWE-617 - Reachable Assertion
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.3
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30034",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T20:08:52.101384Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T20:09:02.333Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V3.3). Affected devices do not properly validate input sent to its listening port on the local loopback interface. This could allow an unauthenticated local attacker to cause a denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617: Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:58.223Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-707630.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-30034",
"datePublished": "2025-08-12T11:16:58.223Z",
"dateReserved": "2025-03-14T13:48:46.135Z",
"dateUpdated": "2025-08-12T20:09:02.333Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33583 (GCVE-0-2024-33583)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:39 UTC
CWE
- CWE-912 - Hidden Functionality
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33583",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:39:01.289567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:50:40.620Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:04.133Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:47.219Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33583",
"datePublished": "2024-05-14T10:03:06.924Z",
"dateReserved": "2024-04-24T14:47:52.265Z",
"dateUpdated": "2024-08-02T02:36:04.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33499 (GCVE-0-2024-33499)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:34 UTC
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:34:44.477523Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:49:58.318Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:03.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:44.706Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33499",
"datePublished": "2024-05-14T10:03:04.171Z",
"dateReserved": "2024-04-23T11:08:04.355Z",
"dateUpdated": "2024-08-02T02:36:03.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33498 (GCVE-0-2024-33498)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:39 UTC
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:39:37.190207Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:49:45.592Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:02.815Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:43.420Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33498",
"datePublished": "2024-05-14T10:03:02.675Z",
"dateReserved": "2024-04-23T11:08:04.355Z",
"dateUpdated": "2024-08-02T02:36:02.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33497 (GCVE-0-2024-33497)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:40 UTC
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33497",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:40:22.212279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:49:29.917Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:02.830Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522: Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:42.140Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33497",
"datePublished": "2024-05-14T10:03:01.146Z",
"dateReserved": "2024-04-23T11:08:04.355Z",
"dateUpdated": "2024-08-02T02:36:02.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33496 (GCVE-0-2024-33496)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:40 UTC
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33496",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:40:50.424175Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:43:25.590Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:03.992Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522: Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:40.834Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33496",
"datePublished": "2024-05-14T10:02:59.612Z",
"dateReserved": "2024-04-23T11:08:04.354Z",
"dateUpdated": "2024-08-02T02:36:03.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33495 (GCVE-0-2024-33495)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application does not properly limit the size of specific logs. This could allow an unauthenticated remote attacker to exhaust system resources by creating a great number of log entries which could potentially lead to a denial of service condition. A successful exploitation requires the attacker to have access to specific SIMATIC RTLS Locating Manager Clients in the deployment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:41 UTC
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33495",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:41:28.915132Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:43:01.644Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:03.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The affected application does not properly limit the size of specific logs. This could allow an unauthenticated remote attacker to exhaust system resources by creating a great number of log entries which could potentially lead to a denial of service condition. A successful exploitation requires the attacker to have access to specific SIMATIC RTLS Locating Manager Clients in the deployment."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:39.548Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33495",
"datePublished": "2024-05-14T10:02:58.115Z",
"dateReserved": "2024-04-23T11:08:04.354Z",
"dateUpdated": "2024-08-02T02:36:03.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33494 (GCVE-0-2024-33494)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:38 UTC
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33494",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:38:06.838394Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:42:46.441Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:02.830Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:38.261Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33494",
"datePublished": "2024-05-14T10:02:56.636Z",
"dateReserved": "2024-04-23T11:08:04.354Z",
"dateUpdated": "2024-08-02T02:36:02.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30209 (GCVE-0-2024-30209)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM).
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-23 18:38 UTC
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30209",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T18:38:46.466956Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T18:38:49.741Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.337Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM)."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:33.239Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30209",
"datePublished": "2024-05-14T10:02:22.448Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.337Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30208 (GCVE-0-2024-30208)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The "DBTest" tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 12:47 UTC
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30208",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:47:49.178921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T16:12:55.825Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.408Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The \"DBTest\" tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:31.948Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30208",
"datePublished": "2024-05-14T10:02:20.970Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30207 (GCVE-0-2024-30207)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.
A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-14 15:39 UTC
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
-
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "-"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30207",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T15:39:49.414605Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:38:28.995Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.426Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.\r\nA successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321: Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:30.666Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30207",
"datePublished": "2024-05-14T10:02:19.474Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.426Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30206 (GCVE-0-2024-30206)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Clients do not properly check the integrity of update files. This could allow an unauthenticated remote attacker to alter update files in transit and trick an authorized user into installing malicious code.
A successful exploit requires the attacker to be able to modify the communication between server and client on the network.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-30 19:35 UTC
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager |
Affected:
0 , < V3.0.1.1
(custom)
|
|
| siemens | simatic_rtls_locating_manager |
Affected:
0 , < 3.0.1.1
(custom)
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_rtls_locating_manager",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30206",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-30T19:35:20.108365Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:38:31.863Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RTLS Locating Manager",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected SIMATIC RTLS Locating Manager Clients do not properly check the integrity of update files. This could allow an unauthenticated remote attacker to alter update files in transit and trick an authorized user into installing malicious code. \r\nA successful exploit requires the attacker to be able to modify the communication between server and client on the network."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:29.386Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-093430.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30206",
"datePublished": "2024-05-14T10:02:17.971Z",
"dateReserved": "2024-03-25T14:21:45.080Z",
"dateUpdated": "2024-08-02T01:25:03.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",