Search

Find a vulnerability

Search criteria

    12 vulnerabilities found for simatic_cn_4100 by siemens

    FKIE_CVE-2023-29131

    Vulnerability from fkie_nvd - Published: 2023-07-11 10:15 - Updated: 2026-10-24 13:10
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation.
    Impacted products
    Vendor Product Version
    siemens simatic_cn_4100_firmware *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.5"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cn_4100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B93A94EF-FF2F-4E02-9C99-F09502947D3E",
                  "versionEndExcluding": "2.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad ha sido identificada en SIMATIC CN 4100 (Todas las versiones anteriores a V2.5). El dispositivo afectado consiste en un valor predeterminado incorrecto en la configuraci\u00f3n SSH. Esto podr\u00eda permitir a un atacante eludir el aislamiento de red."
        }
      ],
      "id": "CVE-2023-29131",
      "lastModified": "2026-10-24T13:10:00.147",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.1,
            "impactScore": 3.7,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 10.0,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.0,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-29131",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-11-12T16:59:58.144249Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-11T10:15:10.473",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-276"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-276"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-29130

    Vulnerability from fkie_nvd - Published: 2023-07-11 10:15 - Updated: 2026-06-17 05:49
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control.
    Impacted products
    Vendor Product Version
    siemens simatic_cn_4100_firmware *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.5"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cn_4100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B93A94EF-FF2F-4E02-9C99-F09502947D3E",
                  "versionEndExcluding": "2.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control."
        }
      ],
      "id": "CVE-2023-29130",
      "lastModified": "2026-06-17T05:49:27.253",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.9,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.1,
            "impactScore": 6.0,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 10.0,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.0,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-29130",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-11-12T17:03:27.280555Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-11T10:15:10.407",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-284"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2024-32742 (GCVE-0-2024-32742)

    Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 12:43 UTC
    CWE
    • CWE-1326 - Missing Immutable Root of Trust in Hardware
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: 0 , < V3.0 (custom)
    Create a notification for this product.
    siemens simatic_cn_4100 Affected: 0 , < 3.0 (custom)
        cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_cn_4100",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32742",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T12:43:18.352073Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:34:34.134Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.285Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1326",
                  "description": "CWE-1326: Missing Immutable Root of Trust in Hardware",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:36.881Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32742",
        "datePublished": "2024-05-14T10:02:49.388Z",
        "dateReserved": "2024-04-17T12:35:40.942Z",
        "dateUpdated": "2024-08-02T02:20:35.285Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32741 (GCVE-0-2024-32741)

    Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 12:45 UTC
    CWE
    • CWE-259 - Use of Hard-coded Password
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: 0 , < V3.0 (custom)
    Create a notification for this product.
    siemens simatic_cn_4100 Affected: 0 , < 3.0 (custom)
        cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_cn_4100",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32741",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T12:45:45.741161Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:34:22.017Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:34.965Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "CWE-259: Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:35.739Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32741",
        "datePublished": "2024-05-14T10:02:48.224Z",
        "dateReserved": "2024-04-17T12:35:40.942Z",
        "dateUpdated": "2024-08-02T02:20:34.965Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32740 (GCVE-0-2024-32740)

    Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 12:46 UTC
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: 0 , < V3.0 (custom)
    Create a notification for this product.
    siemens simatic_cn_4100 Affected: 0 , < 3.0 (custom)
        cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_cn_4100",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32740",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T12:46:23.213597Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:34:09.679Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.369Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device\r\nlocally or over the network."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:34.549Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32740",
        "datePublished": "2024-05-14T10:02:47.049Z",
        "dateReserved": "2024-04-17T12:35:40.941Z",
        "dateUpdated": "2024-08-02T02:20:35.369Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-29131 (GCVE-0-2023-29131)

    Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-12 17:00
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 16:59 UTC
    CWE
    • CWE-276 - Incorrect Default Permissions
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: All versions < V2.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:00:15.794Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-29131",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T16:59:58.144249Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T17:00:15.582Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.5"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276: Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:07.238Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-29131",
        "datePublished": "2023-07-11T09:07:07.238Z",
        "dateReserved": "2023-03-31T10:54:26.824Z",
        "dateUpdated": "2024-11-12T17:00:15.582Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-29130 (GCVE-0-2023-29130)

    Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-12 17:03
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 17:03 UTC
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: All versions < V2.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:00:15.589Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-29130",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T17:03:27.280555Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T17:03:34.510Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.5"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:06.193Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-29130",
        "datePublished": "2023-07-11T09:07:06.193Z",
        "dateReserved": "2023-03-31T10:54:26.823Z",
        "dateUpdated": "2024-11-12T17:03:34.510Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32742 (GCVE-0-2024-32742)

    Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 12:43 UTC
    CWE
    • CWE-1326 - Missing Immutable Root of Trust in Hardware
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: 0 , < V3.0 (custom)
    Create a notification for this product.
    siemens simatic_cn_4100 Affected: 0 , < 3.0 (custom)
        cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_cn_4100",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32742",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T12:43:18.352073Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:34:34.134Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.285Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1326",
                  "description": "CWE-1326: Missing Immutable Root of Trust in Hardware",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:36.881Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32742",
        "datePublished": "2024-05-14T10:02:49.388Z",
        "dateReserved": "2024-04-17T12:35:40.942Z",
        "dateUpdated": "2024-08-02T02:20:35.285Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32741 (GCVE-0-2024-32741)

    Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 12:45 UTC
    CWE
    • CWE-259 - Use of Hard-coded Password
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: 0 , < V3.0 (custom)
    Create a notification for this product.
    siemens simatic_cn_4100 Affected: 0 , < 3.0 (custom)
        cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_cn_4100",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32741",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T12:45:45.741161Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:34:22.017Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:34.965Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "CWE-259: Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:35.739Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32741",
        "datePublished": "2024-05-14T10:02:48.224Z",
        "dateReserved": "2024-04-17T12:35:40.942Z",
        "dateUpdated": "2024-08-02T02:20:34.965Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32740 (GCVE-0-2024-32740)

    Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 12:46 UTC
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: 0 , < V3.0 (custom)
    Create a notification for this product.
    siemens simatic_cn_4100 Affected: 0 , < 3.0 (custom)
        cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_cn_4100",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32740",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T12:46:23.213597Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:34:09.679Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.369Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device\r\nlocally or over the network."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:34.549Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32740",
        "datePublished": "2024-05-14T10:02:47.049Z",
        "dateReserved": "2024-04-17T12:35:40.941Z",
        "dateUpdated": "2024-08-02T02:20:35.369Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-29131 (GCVE-0-2023-29131)

    Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-12 17:00
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 16:59 UTC
    CWE
    • CWE-276 - Incorrect Default Permissions
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: All versions < V2.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:00:15.794Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-29131",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T16:59:58.144249Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T17:00:15.582Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.5"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276: Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:07.238Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-29131",
        "datePublished": "2023-07-11T09:07:07.238Z",
        "dateReserved": "2023-03-31T10:54:26.824Z",
        "dateUpdated": "2024-11-12T17:00:15.582Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-29130 (GCVE-0-2023-29130)

    Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-12 17:03
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 17:03 UTC
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CN 4100 Affected: All versions < V2.5
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:00:15.589Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-29130",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T17:03:27.280555Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T17:03:34.510Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CN 4100",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.5"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:06.193Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-29130",
        "datePublished": "2023-07-11T09:07:06.193Z",
        "dateReserved": "2023-03-31T10:54:26.823Z",
        "dateUpdated": "2024-11-12T17:03:34.510Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }