Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for secflow-1v_firmware by rad

    CVE-2020-13260 (GCVE-0-2020-13260)

    Vulnerability from nvd – Published: 2020-09-17 19:49 – Updated: 2024-08-04 12:11
    VLAI
    Summary
    A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as the static key file in Configuration-Services-Security-OpenVPN-Static Keys. This payload will execute each time a user opens an affected web page. This could be exploited in conjunction with CVE-2020-13259.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:11:19.420Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/48807"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cxsecurity.com/issue/WLB-2020090063"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as the static key file in Configuration-Services-Security-OpenVPN-Static Keys. This payload will execute each time a user opens an affected web page. This could be exploited in conjunction with CVE-2020-13259."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-17T19:49:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.exploit-db.com/exploits/48807"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cxsecurity.com/issue/WLB-2020090063"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-13260",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as the static key file in Configuration-Services-Security-OpenVPN-Static Keys. This payload will execute each time a user opens an affected web page. This could be exploited in conjunction with CVE-2020-13259."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837",
                  "refsource": "MISC",
                  "url": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837"
                },
                {
                  "name": "https://www.exploit-db.com/exploits/48807",
                  "refsource": "MISC",
                  "url": "https://www.exploit-db.com/exploits/48807"
                },
                {
                  "name": "https://cxsecurity.com/issue/WLB-2020090063",
                  "refsource": "MISC",
                  "url": "https://cxsecurity.com/issue/WLB-2020090063"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-13260",
        "datePublished": "2020-09-17T19:49:01.000Z",
        "dateReserved": "2020-05-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T12:11:19.420Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-13259 (GCVE-0-2020-13259)

    Vulnerability from nvd – Published: 2020-09-16 18:27 – Updated: 2024-08-04 12:11
    VLAI
    Summary
    A vulnerability in the web-based management interface of RAD SecFlow-1v os-image SF_0290_2.3.01.26 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web UI on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. This could be exploited in conjunction with CVE-2020-13260.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://cxsecurity.com/issue/WLB-2020090064 x_refsource_MISC
    https://www.exploit-db.com/exploits/48809 exploitx_refsource_EXPLOIT-DB
    Date Public
    2020-08-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:11:19.450Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cxsecurity.com/issue/WLB-2020090064"
              },
              {
                "name": "48809",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/48809"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2020-08-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v os-image SF_0290_2.3.01.26 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web UI on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. This could be exploited in conjunction with CVE-2020-13260."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-16T18:27:44.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cxsecurity.com/issue/WLB-2020090064"
            },
            {
              "name": "48809",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/48809"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-13259",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v os-image SF_0290_2.3.01.26 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web UI on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. This could be exploited in conjunction with CVE-2020-13260."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cxsecurity.com/issue/WLB-2020090064",
                  "refsource": "MISC",
                  "url": "https://cxsecurity.com/issue/WLB-2020090064"
                },
                {
                  "name": "48809",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/48809"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-13259",
        "datePublished": "2020-09-16T18:27:44.000Z",
        "dateReserved": "2020-05-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T12:11:19.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-13260 (GCVE-0-2020-13260)

    Vulnerability from cvelistv5 – Published: 2020-09-17 19:49 – Updated: 2024-08-04 12:11
    VLAI
    Summary
    A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as the static key file in Configuration-Services-Security-OpenVPN-Static Keys. This payload will execute each time a user opens an affected web page. This could be exploited in conjunction with CVE-2020-13259.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:11:19.420Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/48807"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cxsecurity.com/issue/WLB-2020090063"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as the static key file in Configuration-Services-Security-OpenVPN-Static Keys. This payload will execute each time a user opens an affected web page. This could be exploited in conjunction with CVE-2020-13259."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-17T19:49:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.exploit-db.com/exploits/48807"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cxsecurity.com/issue/WLB-2020090063"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-13260",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v through 2020-05-21 could allow an authenticated attacker to upload a JavaScript file, with a stored XSS payload, that will remain stored in the system as an OVPN file in Configuration-Services-Security-OpenVPN-Config or as the static key file in Configuration-Services-Security-OpenVPN-Static Keys. This payload will execute each time a user opens an affected web page. This could be exploited in conjunction with CVE-2020-13259."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837",
                  "refsource": "MISC",
                  "url": "https://www.rad.com/products/secflow-1v-IIoT-Gateway#panels-ipe-paneid-143837"
                },
                {
                  "name": "https://www.exploit-db.com/exploits/48807",
                  "refsource": "MISC",
                  "url": "https://www.exploit-db.com/exploits/48807"
                },
                {
                  "name": "https://cxsecurity.com/issue/WLB-2020090063",
                  "refsource": "MISC",
                  "url": "https://cxsecurity.com/issue/WLB-2020090063"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-13260",
        "datePublished": "2020-09-17T19:49:01.000Z",
        "dateReserved": "2020-05-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T12:11:19.420Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-13259 (GCVE-0-2020-13259)

    Vulnerability from cvelistv5 – Published: 2020-09-16 18:27 – Updated: 2024-08-04 12:11
    VLAI
    Summary
    A vulnerability in the web-based management interface of RAD SecFlow-1v os-image SF_0290_2.3.01.26 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web UI on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. This could be exploited in conjunction with CVE-2020-13260.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://cxsecurity.com/issue/WLB-2020090064 x_refsource_MISC
    https://www.exploit-db.com/exploits/48809 exploitx_refsource_EXPLOIT-DB
    Date Public
    2020-08-25 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:11:19.450Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cxsecurity.com/issue/WLB-2020090064"
              },
              {
                "name": "48809",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/48809"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2020-08-25T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v os-image SF_0290_2.3.01.26 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web UI on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. This could be exploited in conjunction with CVE-2020-13260."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-09-16T18:27:44.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cxsecurity.com/issue/WLB-2020090064"
            },
            {
              "name": "48809",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/48809"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-13259",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in the web-based management interface of RAD SecFlow-1v os-image SF_0290_2.3.01.26 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web UI on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. This could be exploited in conjunction with CVE-2020-13260."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cxsecurity.com/issue/WLB-2020090064",
                  "refsource": "MISC",
                  "url": "https://cxsecurity.com/issue/WLB-2020090064"
                },
                {
                  "name": "48809",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/48809"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-13259",
        "datePublished": "2020-09-16T18:27:44.000Z",
        "dateReserved": "2020-05-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T12:11:19.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }