Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for scroll_medical_air_systems_firmware by beaconmedaes

    CVE-2018-7510 (GCVE-0-2018-7510)

    Vulnerability from nvd – Published: 2018-06-06 20:00 – Updated: 2024-09-16 22:20
    VLAI
    Summary
    In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication.
    Severity
    No CVSS data available.
    CWE
    • CWE-256 - UNPROTECTED STORAGE OF CREDENTIALS CWE-256
    Assigner
    References
    Impacted products
    Vendor Product Version
    ICS-CERT BeaconMedaes TotalAlert Scroll Medical Air Systems web application Affected: All versions prior to version 4107600010.23
    Create a notification for this product.
    Date Public
    2018-05-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:04.305Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BeaconMedaes TotalAlert Scroll Medical Air Systems web application",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4107600010.23"
                }
              ]
            }
          ],
          "datePublic": "2018-05-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "UNPROTECTED STORAGE OF CREDENTIALS CWE-256",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-06T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-24T00:00:00",
              "ID": "CVE-2018-7510",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BeaconMedaes TotalAlert Scroll Medical Air Systems web application",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4107600010.23"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ICS-CERT"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNPROTECTED STORAGE OF CREDENTIALS CWE-256"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7510",
        "datePublished": "2018-06-06T20:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:20:39.855Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7526 (GCVE-0-2018-7526)

    Vulnerability from nvd – Published: 2018-05-24 20:00 – Updated: 2024-08-05 06:31
    VLAI
    Summary
    In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-05-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:03.728Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-05-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-24T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-7526",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7526",
        "datePublished": "2018-05-24T20:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:31:03.728Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7518 (GCVE-0-2018-7518)

    Vulnerability from nvd – Published: 2018-05-24 20:00 – Updated: 2024-09-16 22:41
    VLAI
    Summary
    In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.
    Severity
    No CVSS data available.
    CWE
    • CWE-522 - INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522
    Assigner
    References
    Impacted products
    Date Public
    2018-05-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:04.252Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BeaconMed\u0026#195;\u0026#166;s TotalAlert Scroll Medical Air Systems web application",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4107600010.23"
                }
              ]
            }
          ],
          "datePublic": "2018-05-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-24T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-24T00:00:00",
              "ID": "CVE-2018-7518",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BeaconMed\u0026#195;\u0026#166;s TotalAlert Scroll Medical Air Systems web application",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4107600010.23"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ICS-CERT"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7518",
        "datePublished": "2018-05-24T20:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:41:11.097Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7510 (GCVE-0-2018-7510)

    Vulnerability from cvelistv5 – Published: 2018-06-06 20:00 – Updated: 2024-09-16 22:20
    VLAI
    Summary
    In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication.
    Severity
    No CVSS data available.
    CWE
    • CWE-256 - UNPROTECTED STORAGE OF CREDENTIALS CWE-256
    Assigner
    References
    Impacted products
    Vendor Product Version
    ICS-CERT BeaconMedaes TotalAlert Scroll Medical Air Systems web application Affected: All versions prior to version 4107600010.23
    Create a notification for this product.
    Date Public
    2018-05-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:04.305Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BeaconMedaes TotalAlert Scroll Medical Air Systems web application",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4107600010.23"
                }
              ]
            }
          ],
          "datePublic": "2018-05-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "UNPROTECTED STORAGE OF CREDENTIALS CWE-256",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-06T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-24T00:00:00",
              "ID": "CVE-2018-7510",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BeaconMedaes TotalAlert Scroll Medical Air Systems web application",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4107600010.23"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ICS-CERT"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNPROTECTED STORAGE OF CREDENTIALS CWE-256"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7510",
        "datePublished": "2018-06-06T20:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:20:39.855Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7526 (GCVE-0-2018-7526)

    Vulnerability from cvelistv5 – Published: 2018-05-24 20:00 – Updated: 2024-08-05 06:31
    VLAI
    Summary
    In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-05-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:03.728Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-05-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-24T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-7526",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7526",
        "datePublished": "2018-05-24T20:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:31:03.728Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7518 (GCVE-0-2018-7518)

    Vulnerability from cvelistv5 – Published: 2018-05-24 20:00 – Updated: 2024-09-16 22:41
    VLAI
    Summary
    In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.
    Severity
    No CVSS data available.
    CWE
    • CWE-522 - INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522
    Assigner
    References
    Impacted products
    Date Public
    2018-05-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:04.252Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BeaconMed\u0026#195;\u0026#166;s TotalAlert Scroll Medical Air Systems web application",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4107600010.23"
                }
              ]
            }
          ],
          "datePublic": "2018-05-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-24T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-24T00:00:00",
              "ID": "CVE-2018-7518",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BeaconMed\u0026#195;\u0026#166;s TotalAlert Scroll Medical Air Systems web application",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4107600010.23"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ICS-CERT"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-144-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7518",
        "datePublished": "2018-05-24T20:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:41:11.097Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }