Search
Find a vulnerability
Search criteria
8 vulnerabilities found for rx_3000_firmware by intelbras
CVE-2025-26065 (GCVE-0-2025-26065)
Vulnerability from nvd – Published: 2025-08-04 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network.
Severity
7.3 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26065",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-04T14:46:46.073181Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T14:48:45.605Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:20.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T14:14:46.874Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/26"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26065",
"datePublished": "2025-08-04T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:20.059Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26064 (GCVE-0-2025-26064)
Vulnerability from nvd – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device.
Severity
7.3 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26064",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-31T19:29:25.304480Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T19:30:25.447Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:18.531Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T18:43:25.551Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26064",
"datePublished": "2025-07-31T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:18.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26063 (GCVE-0-2025-26063)
Vulnerability from nvd – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26063",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-31T19:34:56.023904Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T19:35:46.460Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:15.195Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T18:42:35.162Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26063",
"datePublished": "2025-07-31T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:15.195Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26062 (GCVE-0-2025-26062)
Vulnerability from nvd – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router's settings file and obtain potentially sensitive information from the current settings.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26062",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-31T19:41:25.877976Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T19:42:07.212Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:12.355Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router\u0027s settings file and obtain potentially sensitive information from the current settings."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T18:42:04.096Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26062",
"datePublished": "2025-07-31T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:12.355Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26065 (GCVE-0-2025-26065)
Vulnerability from cvelistv5 – Published: 2025-08-04 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network.
Severity
7.3 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26065",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-04T14:46:46.073181Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T14:48:45.605Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:20.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T14:14:46.874Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/26"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26065",
"datePublished": "2025-08-04T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:20.059Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26062 (GCVE-0-2025-26062)
Vulnerability from cvelistv5 – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router's settings file and obtain potentially sensitive information from the current settings.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26062",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-31T19:41:25.877976Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T19:42:07.212Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:12.355Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router\u0027s settings file and obtain potentially sensitive information from the current settings."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T18:42:04.096Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26062",
"datePublished": "2025-07-31T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:12.355Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26063 (GCVE-0-2025-26063)
Vulnerability from cvelistv5 – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26063",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-31T19:34:56.023904Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T19:35:46.460Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:15.195Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T18:42:35.162Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26063",
"datePublished": "2025-07-31T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:15.195Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26064 (GCVE-0-2025-26064)
Vulnerability from cvelistv5 – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device.
Severity
7.3 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26064",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-31T19:29:25.304480Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T19:30:25.447Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:45:18.531Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/26"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-31T18:43:25.551Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
},
{
"url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
},
{
"url": "https://seclists.org/fulldisclosure/2025/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-26064",
"datePublished": "2025-07-31T00:00:00.000Z",
"dateReserved": "2025-02-07T00:00:00.000Z",
"dateUpdated": "2025-11-03T19:45:18.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}