Search criteria

18 vulnerabilities found for rx9_pro_firmware by tenda

CVE-2024-10351 (GCVE-0-2024-10351)

Vulnerability from nvd – Published: 2024-10-24 23:31 – Updated: 2024-10-25 20:50
VLAI?
Title
Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow
Summary
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Pro Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:rx9_pro_firmware:22.03.02.20:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10351",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T20:00:12.566902Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T20:50:14.294Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "POST Request Handler"
          ],
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX9 Pro 22.03.02.20 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion sub_424CE0 der Datei /goform/setMacFilterCfg der Komponente POST Request Handler. Dank der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-24T23:31:11.527Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281699 | Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281699"
        },
        {
          "name": "VDB-281699 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281699"
        },
        {
          "name": "Submit #427706 | Tenda Rx9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427706"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/setMacFilterCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-24T17:39:44.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10351",
    "datePublished": "2024-10-24T23:31:11.527Z",
    "dateReserved": "2024-10-24T15:34:29.365Z",
    "dateUpdated": "2024-10-25T20:50:14.294Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10283 (GCVE-0-2024-10283)

Vulnerability from nvd – Published: 2024-10-23 15:00 – Updated: 2024-10-23 17:33
VLAI?
Title
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10283",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:30:46.351880Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:33:05.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda RX9 and RX9 Pro 22.03.02.20 entdeckt. Betroffen davon ist die Funktion sub_4337EC der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T15:00:12.454Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281558 | Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281558"
        },
        {
          "name": "VDB-281558 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281558"
        },
        {
          "name": "Submit #427064 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427064"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetNetControlList.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:57.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10283",
    "datePublished": "2024-10-23T15:00:12.454Z",
    "dateReserved": "2024-10-23T06:07:52.411Z",
    "dateUpdated": "2024-10-23T17:33:05.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10282 (GCVE-0-2024-10282)

Vulnerability from nvd – Published: 2024-10-23 14:31 – Updated: 2024-10-23 17:51
VLAI?
Title
Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
    Tenda RX9 Pro Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10282",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:50:18.481537Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:51:56.577Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion sub_42EA38 der Datei /goform/SetVirtualServerCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T14:31:24.051Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281557 | Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281557"
        },
        {
          "name": "VDB-281557 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281557"
        },
        {
          "name": "Submit #427066 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427066"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetVirtualServerCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:46.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10282",
    "datePublished": "2024-10-23T14:31:24.051Z",
    "dateReserved": "2024-10-23T06:07:37.708Z",
    "dateUpdated": "2024-10-23T17:51:56.577Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10281 (GCVE-0-2024-10281)

Vulnerability from nvd – Published: 2024-10-23 14:00 – Updated: 2024-10-23 18:20
VLAI?
Title
Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
    Tenda RX9 Pro Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10281",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T18:19:28.352564Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T18:20:52.773Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 entdeckt. Hiervon betroffen ist die Funktion sub_42EEE0 der Datei /goform/SetStaticRouteCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T14:00:24.603Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281556 | Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281556"
        },
        {
          "name": "VDB-281556 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281556"
        },
        {
          "name": "Submit #427065 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427065"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetStaticRouteCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10281",
    "datePublished": "2024-10-23T14:00:24.603Z",
    "dateReserved": "2024-10-23T06:07:35.435Z",
    "dateUpdated": "2024-10-23T18:20:52.773Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-43886 (GCVE-0-2023-43886)

Vulnerability from nvd – Published: 2023-11-07 00:00 – Updated: 2024-09-05 13:15
VLAI?
Summary
A buffer overflow in the HTTP server component of Tenda RX9 Pro v22.03.02.20 might allow an authenticated attacker to overwrite memory.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:52:11.901Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-43886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-05T13:15:00.595016Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-05T13:15:21.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow in the HTTP server component of Tenda RX9 Pro v22.03.02.20 might allow an authenticated attacker to overwrite memory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-07T08:02:02.446414",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-43886",
    "datePublished": "2023-11-07T00:00:00",
    "dateReserved": "2023-09-25T00:00:00",
    "dateUpdated": "2024-09-05T13:15:21.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-43885 (GCVE-0-2023-43885)

Vulnerability from nvd – Published: 2023-11-07 00:00 – Updated: 2024-09-05 13:17
VLAI?
Summary
Missing error handling in the HTTP server component of Tenda RX9 Pro Firmware V22.03.02.20 allows authenticated attackers to arbitrarily lock the device.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:52:11.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-43885",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-05T13:16:30.532648Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-05T13:17:13.925Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Missing error handling in the HTTP server component of Tenda RX9 Pro Firmware V22.03.02.20 allows authenticated attackers to arbitrarily lock the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-07T08:01:59.519117",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-43885",
    "datePublished": "2023-11-07T00:00:00",
    "dateReserved": "2023-09-25T00:00:00",
    "dateUpdated": "2024-09-05T13:17:13.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38831 (GCVE-0-2022-38831)

Vulnerability from nvd – Published: 2022-09-16 14:35 – Updated: 2024-08-03 11:02
VLAI?
Summary
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:02:14.625Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-16T14:35:43",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38831",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md",
              "refsource": "MISC",
              "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38831",
    "datePublished": "2022-09-16T14:35:43",
    "dateReserved": "2022-08-29T00:00:00",
    "dateUpdated": "2024-08-03T11:02:14.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38830 (GCVE-0-2022-38830)

Vulnerability from nvd – Published: 2022-09-16 14:36 – Updated: 2024-08-03 11:02
VLAI?
Summary
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:02:14.603Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-16T14:36:48",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38830",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md",
              "refsource": "MISC",
              "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38830",
    "datePublished": "2022-09-16T14:36:48",
    "dateReserved": "2022-08-29T00:00:00",
    "dateUpdated": "2024-08-03T11:02:14.603Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38829 (GCVE-0-2022-38829)

Vulnerability from nvd – Published: 2022-09-16 14:37 – Updated: 2024-08-03 11:02
VLAI?
Summary
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:02:14.605Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-16T14:37:40",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38829",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md",
              "refsource": "MISC",
              "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38829",
    "datePublished": "2022-09-16T14:37:40",
    "dateReserved": "2022-08-29T00:00:00",
    "dateUpdated": "2024-08-03T11:02:14.605Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10351 (GCVE-0-2024-10351)

Vulnerability from cvelistv5 – Published: 2024-10-24 23:31 – Updated: 2024-10-25 20:50
VLAI?
Title
Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow
Summary
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Pro Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:rx9_pro_firmware:22.03.02.20:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10351",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T20:00:12.566902Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T20:50:14.294Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "POST Request Handler"
          ],
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX9 Pro 22.03.02.20 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion sub_424CE0 der Datei /goform/setMacFilterCfg der Komponente POST Request Handler. Dank der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-24T23:31:11.527Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281699 | Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281699"
        },
        {
          "name": "VDB-281699 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281699"
        },
        {
          "name": "Submit #427706 | Tenda Rx9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427706"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/setMacFilterCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-24T17:39:44.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10351",
    "datePublished": "2024-10-24T23:31:11.527Z",
    "dateReserved": "2024-10-24T15:34:29.365Z",
    "dateUpdated": "2024-10-25T20:50:14.294Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10283 (GCVE-0-2024-10283)

Vulnerability from cvelistv5 – Published: 2024-10-23 15:00 – Updated: 2024-10-23 17:33
VLAI?
Title
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10283",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:30:46.351880Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:33:05.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda RX9 and RX9 Pro 22.03.02.20 entdeckt. Betroffen davon ist die Funktion sub_4337EC der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T15:00:12.454Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281558 | Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281558"
        },
        {
          "name": "VDB-281558 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281558"
        },
        {
          "name": "Submit #427064 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427064"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetNetControlList.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:57.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10283",
    "datePublished": "2024-10-23T15:00:12.454Z",
    "dateReserved": "2024-10-23T06:07:52.411Z",
    "dateUpdated": "2024-10-23T17:33:05.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10282 (GCVE-0-2024-10282)

Vulnerability from cvelistv5 – Published: 2024-10-23 14:31 – Updated: 2024-10-23 17:51
VLAI?
Title
Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
    Tenda RX9 Pro Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10282",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:50:18.481537Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:51:56.577Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion sub_42EA38 der Datei /goform/SetVirtualServerCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T14:31:24.051Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281557 | Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281557"
        },
        {
          "name": "VDB-281557 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281557"
        },
        {
          "name": "Submit #427066 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427066"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetVirtualServerCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:46.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10282",
    "datePublished": "2024-10-23T14:31:24.051Z",
    "dateReserved": "2024-10-23T06:07:37.708Z",
    "dateUpdated": "2024-10-23T17:51:56.577Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10281 (GCVE-0-2024-10281)

Vulnerability from cvelistv5 – Published: 2024-10-23 14:00 – Updated: 2024-10-23 18:20
VLAI?
Title
Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
    Tenda RX9 Pro Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10281",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T18:19:28.352564Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T18:20:52.773Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 entdeckt. Hiervon betroffen ist die Funktion sub_42EEE0 der Datei /goform/SetStaticRouteCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T14:00:24.603Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281556 | Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281556"
        },
        {
          "name": "VDB-281556 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281556"
        },
        {
          "name": "Submit #427065 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427065"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetStaticRouteCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10281",
    "datePublished": "2024-10-23T14:00:24.603Z",
    "dateReserved": "2024-10-23T06:07:35.435Z",
    "dateUpdated": "2024-10-23T18:20:52.773Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-43885 (GCVE-0-2023-43885)

Vulnerability from cvelistv5 – Published: 2023-11-07 00:00 – Updated: 2024-09-05 13:17
VLAI?
Summary
Missing error handling in the HTTP server component of Tenda RX9 Pro Firmware V22.03.02.20 allows authenticated attackers to arbitrarily lock the device.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:52:11.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-43885",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-05T13:16:30.532648Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-05T13:17:13.925Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Missing error handling in the HTTP server component of Tenda RX9 Pro Firmware V22.03.02.20 allows authenticated attackers to arbitrarily lock the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-07T08:01:59.519117",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-43885",
    "datePublished": "2023-11-07T00:00:00",
    "dateReserved": "2023-09-25T00:00:00",
    "dateUpdated": "2024-09-05T13:17:13.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-43886 (GCVE-0-2023-43886)

Vulnerability from cvelistv5 – Published: 2023-11-07 00:00 – Updated: 2024-09-05 13:15
VLAI?
Summary
A buffer overflow in the HTTP server component of Tenda RX9 Pro v22.03.02.20 might allow an authenticated attacker to overwrite memory.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:52:11.901Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-43886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-05T13:15:00.595016Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-05T13:15:21.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow in the HTTP server component of Tenda RX9 Pro v22.03.02.20 might allow an authenticated attacker to overwrite memory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-07T08:02:02.446414",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://blog.rtlcopymemory.com/tenda-rx9-pro/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-43886",
    "datePublished": "2023-11-07T00:00:00",
    "dateReserved": "2023-09-25T00:00:00",
    "dateUpdated": "2024-09-05T13:15:21.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38829 (GCVE-0-2022-38829)

Vulnerability from cvelistv5 – Published: 2022-09-16 14:37 – Updated: 2024-08-03 11:02
VLAI?
Summary
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:02:14.605Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-16T14:37:40",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38829",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md",
              "refsource": "MISC",
              "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setMacFilterCfg.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38829",
    "datePublished": "2022-09-16T14:37:40",
    "dateReserved": "2022-08-29T00:00:00",
    "dateUpdated": "2024-08-03T11:02:14.605Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38830 (GCVE-0-2022-38830)

Vulnerability from cvelistv5 – Published: 2022-09-16 14:36 – Updated: 2024-08-03 11:02
VLAI?
Summary
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:02:14.603Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-16T14:36:48",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38830",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md",
              "refsource": "MISC",
              "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/setIPv6Status.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38830",
    "datePublished": "2022-09-16T14:36:48",
    "dateReserved": "2022-08-29T00:00:00",
    "dateUpdated": "2024-08-03T11:02:14.603Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38831 (GCVE-0-2022-38831)

Vulnerability from cvelistv5 – Published: 2022-09-16 14:35 – Updated: 2024-08-03 11:02
VLAI?
Summary
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:02:14.625Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-16T14:35:43",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-38831",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md",
              "refsource": "MISC",
              "url": "https://github.com/whiter6666/CVE/blob/main/Tenda_RX9_Pro/SetNetControlList.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-38831",
    "datePublished": "2022-09-16T14:35:43",
    "dateReserved": "2022-08-29T00:00:00",
    "dateUpdated": "2024-08-03T11:02:14.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}