Search criteria

2 vulnerabilities found for rv4frlm\/c_firmware by mitsubishielectric

CVE-2021-20586 (GCVE-0-2021-20586)

Vulnerability from nvd – Published: 2021-01-29 14:54 – Updated: 2024-08-03 17:45
VLAI?
Summary
Resource management errors vulnerability in a robot controller of MELFA FR Series(controller "CR800-*V*D" of RV-*FR***-D-* all versions, controller "CR800-*HD" of RH-*FRH***-D-* all versions, controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller "CR800-CVD" of RV-8CRL-D-* all versions, controller "CR800-CHD" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller "CR800-05VD" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs.
Severity ?
No CVSS data available.
CWE
  • Resource management errors
Assigner
References
Impacted products
Vendor Product Version
n/a Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA Affected: Controller "CR800-*V*D" of RV-*FR***-D-* all versions, Controller "CR800-*HD" of RH-*FRH***-D-* all versions, Controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, Controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, Controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, Controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, Controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, Controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, Controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions
Affected: Controller "CR800-CVD" of RV-8CRL-D-* all versions, Controller "CR800-CHD" of RH-*CRH**-D-* all versions
Affected: Controller "CR800-05VD" of RV-5AS-D-* all versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.779Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, Controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, Controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, Controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, Controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, Controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, Controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, Controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, Controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions"
            },
            {
              "status": "affected",
              "version": "Controller \"CR800-CVD\" of RV-8CRL-D-* all versions, Controller \"CR800-CHD\" of RH-*CRH**-D-* all versions"
            },
            {
              "status": "affected",
              "version": "Controller \"CR800-05VD\" of RV-5AS-D-* all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Resource management errors vulnerability in a robot controller of MELFA FR Series(controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller \"CR800-CVD\" of RV-8CRL-D-* all versions, controller \"CR800-CHD\" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller \"CR800-05VD\" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Resource management errors",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-29T14:54:32",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
          "ID": "CVE-2021-20586",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, Controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, Controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, Controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, Controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, Controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, Controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, Controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, Controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions"
                          },
                          {
                            "version_value": "Controller \"CR800-CVD\" of RV-8CRL-D-* all versions, Controller \"CR800-CHD\" of RH-*CRH**-D-* all versions"
                          },
                          {
                            "version_value": "Controller \"CR800-05VD\" of RV-5AS-D-* all versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Resource management errors vulnerability in a robot controller of MELFA FR Series(controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller \"CR800-CVD\" of RV-8CRL-D-* all versions, controller \"CR800-CHD\" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller \"CR800-05VD\" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Resource management errors"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20586",
    "datePublished": "2021-01-29T14:54:32",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:45:44.779Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-20586 (GCVE-0-2021-20586)

Vulnerability from cvelistv5 – Published: 2021-01-29 14:54 – Updated: 2024-08-03 17:45
VLAI?
Summary
Resource management errors vulnerability in a robot controller of MELFA FR Series(controller "CR800-*V*D" of RV-*FR***-D-* all versions, controller "CR800-*HD" of RH-*FRH***-D-* all versions, controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller "CR800-CVD" of RV-8CRL-D-* all versions, controller "CR800-CHD" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller "CR800-05VD" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs.
Severity ?
No CVSS data available.
CWE
  • Resource management errors
Assigner
References
Impacted products
Vendor Product Version
n/a Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA Affected: Controller "CR800-*V*D" of RV-*FR***-D-* all versions, Controller "CR800-*HD" of RH-*FRH***-D-* all versions, Controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, Controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, Controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, Controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, Controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, Controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, Controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions
Affected: Controller "CR800-CVD" of RV-8CRL-D-* all versions, Controller "CR800-CHD" of RH-*CRH**-D-* all versions
Affected: Controller "CR800-05VD" of RV-5AS-D-* all versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.779Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, Controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, Controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, Controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, Controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, Controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, Controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, Controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, Controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions"
            },
            {
              "status": "affected",
              "version": "Controller \"CR800-CVD\" of RV-8CRL-D-* all versions, Controller \"CR800-CHD\" of RH-*CRH**-D-* all versions"
            },
            {
              "status": "affected",
              "version": "Controller \"CR800-05VD\" of RV-5AS-D-* all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Resource management errors vulnerability in a robot controller of MELFA FR Series(controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller \"CR800-CVD\" of RV-8CRL-D-* all versions, controller \"CR800-CHD\" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller \"CR800-05VD\" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Resource management errors",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-29T14:54:32",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
          "ID": "CVE-2021-20586",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, Controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, Controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, Controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, Controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, Controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, Controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, Controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, Controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions"
                          },
                          {
                            "version_value": "Controller \"CR800-CVD\" of RV-8CRL-D-* all versions, Controller \"CR800-CHD\" of RH-*CRH**-D-* all versions"
                          },
                          {
                            "version_value": "Controller \"CR800-05VD\" of RV-5AS-D-* all versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Resource management errors vulnerability in a robot controller of MELFA FR Series(controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller \"CR800-CVD\" of RV-8CRL-D-* all versions, controller \"CR800-CHD\" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller \"CR800-05VD\" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Resource management errors"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20586",
    "datePublished": "2021-01-29T14:54:32",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:45:44.779Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}