Search
Find a vulnerability
Search criteria
18 vulnerabilities found for ruggedcom_rugged_operating_system by siemens
CVE-2015-7836 (GCVE-0-2015-7836)
Vulnerability from nvd – Published: 2015-10-28 10:00 – Updated: 2024-08-06 07:59
VLAI
Summary
Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.siemens.com/cert/pool/cert/siemens_sec… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1033973 | vdb-entryx_refsource_SECTRACK |
| https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01 | x_refsource_MISC |
Date Public
2015-10-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T07:59:00.583Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf"
},
{
"name": "1033973",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033973"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-10-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-09-14T09:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf"
},
{
"name": "1033973",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1033973"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-7836",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf"
},
{
"name": "1033973",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1033973"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-7836",
"datePublished": "2015-10-28T10:00:00.000Z",
"dateReserved": "2015-10-15T00:00:00.000Z",
"dateUpdated": "2024-08-06T07:59:00.583Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-6675 (GCVE-0-2015-6675)
Vulnerability from nvd – Published: 2015-09-11 16:00 – Updated: 2024-08-06 07:29
VLAI
Summary
Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.siemens.com/cert/pool/cert/siemens_sec… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1033478 | vdb-entryx_refsource_SECTRACK |
| https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01 | x_refsource_MISC |
Date Public
2015-09-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T07:29:24.434Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf"
},
{
"name": "1033478",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033478"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-09-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-20T16:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf"
},
{
"name": "1033478",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1033478"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-6675",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf"
},
{
"name": "1033478",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1033478"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-6675",
"datePublished": "2015-09-11T16:00:00.000Z",
"dateReserved": "2015-08-26T00:00:00.000Z",
"dateUpdated": "2024-08-06T07:29:24.434Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-5537 (GCVE-0-2015-5537)
Vulnerability from nvd – Published: 2015-08-03 01:00 – Updated: 2024-08-06 06:50
VLAI
Summary
The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulnerability than CVE-2014-3566.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.securitytracker.com/id/1033022 | vdb-entryx_refsource_SECTRACK |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
| https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A | x_refsource_MISC |
Date Public
2015-07-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T06:50:02.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1033022",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033022"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-07-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulnerability than CVE-2014-3566."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-09-20T09:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "1033022",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1033022"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-5537",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulnerability than CVE-2014-3566."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1033022",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1033022"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-5537",
"datePublished": "2015-08-03T01:00:00.000Z",
"dateReserved": "2015-07-17T00:00:00.000Z",
"dateUpdated": "2024-08-06T06:50:02.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2590 (GCVE-0-2014-2590)
Vulnerability from nvd – Published: 2014-03-28 19:00 – Updated: 2024-08-06 10:21
VLAI
Summary
The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01 | x_refsource_MISC |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
Date Public
2014-03-28 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:21:35.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2014-03-28T19:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2590",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2590",
"datePublished": "2014-03-28T19:00:00.000Z",
"dateReserved": "2014-03-24T00:00:00.000Z",
"dateUpdated": "2024-08-06T10:21:35.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-1966 (GCVE-0-2014-1966)
Vulnerability from nvd – Published: 2014-02-24 02:00 – Updated: 2024-08-06 09:58
VLAI
Summary
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
| http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03 | x_refsource_MISC |
Date Public
2014-02-20 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T09:58:15.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-02-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2014-02-24T02:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-1966",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-1966",
"datePublished": "2014-02-24T02:00:00.000Z",
"dateReserved": "2014-02-17T00:00:00.000Z",
"dateUpdated": "2024-08-06T09:58:15.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-6926 (GCVE-0-2013-6926)
Vulnerability from nvd – Published: 2013-12-17 02:00 – Updated: 2024-08-06 17:53
VLAI
Summary
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01 | x_refsource_MISC |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
Date Public
2013-12-06 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T17:53:45.172Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-12-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-12-17T02:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-6926",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-6926",
"datePublished": "2013-12-17T02:00:00.000Z",
"dateReserved": "2013-12-03T00:00:00.000Z",
"dateUpdated": "2024-08-06T17:53:45.172Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-6925 (GCVE-0-2013-6925)
Vulnerability from nvd – Published: 2013-12-17 02:00 – Updated: 2024-08-06 17:53
VLAI
Summary
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01 | x_refsource_MISC |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
Date Public
2013-12-06 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T17:53:44.793Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-12-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-12-17T02:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-6925",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-6925",
"datePublished": "2013-12-17T02:00:00.000Z",
"dateReserved": "2013-12-03T00:00:00.000Z",
"dateUpdated": "2024-08-06T17:53:44.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-2441 (GCVE-0-2012-2441)
Vulnerability from nvd – Published: 2012-04-28 00:00 – Updated: 2024-08-06 19:34
VLAI
Summary
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
7 references
| URL | Tags |
|---|---|
| http://www.wired.com/threatlevel/2012/04/ruggedco… | x_refsource_MISC |
| http://www.kb.cert.org/vuls/id/889195 | third-party-advisoryx_refsource_CERT-VN |
| http://www.ruggedcom.com/productbulletin/ros-secu… | x_refsource_CONFIRM |
| http://www.us-cert.gov/control_systems/pdf/ICS-AL… | x_refsource_MISC |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://seclists.org/fulldisclosure/2012/Apr/277 | mailing-listx_refsource_FULLDISC |
| http://arstechnica.com/business/news/2012/04/back… | x_refsource_MISC |
Date Public
2012-04-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:34:25.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "ruggedcom-unauth-access(75244)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75244"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-04-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-12-13T18:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "ruggedcom-unauth-access(75244)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75244"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-2441",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/",
"refsource": "MISC",
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "VU#889195",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "http://www.ruggedcom.com/productbulletin/ros-security-page/",
"refsource": "CONFIRM",
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "ruggedcom-unauth-access(75244)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75244"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"name": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars",
"refsource": "MISC",
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-2441",
"datePublished": "2012-04-28T00:00:00.000Z",
"dateReserved": "2012-04-27T00:00:00.000Z",
"dateUpdated": "2024-08-06T19:34:25.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-1803 (GCVE-0-2012-1803)
Vulnerability from nvd – Published: 2012-04-28 00:00 – Updated: 2024-08-06 19:08
VLAI
Summary
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
12 references
| URL | Tags |
|---|---|
| http://www.wired.com/threatlevel/2012/04/ruggedco… | x_refsource_MISC |
| http://www.exploit-db.com/exploits/18779 | exploitx_refsource_EXPLOIT-DB |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://www.kb.cert.org/vuls/id/889195 | third-party-advisoryx_refsource_CERT-VN |
| http://archives.neohapsis.com/archives/bugtraq/20… | mailing-listx_refsource_BUGTRAQ |
| http://www.ruggedcom.com/productbulletin/ros-secu… | x_refsource_CONFIRM |
| http://www.us-cert.gov/control_systems/pdf/ICS-AL… | x_refsource_MISC |
| http://www.kb.cert.org/vuls/id/MAPG-8RCPEN | x_refsource_CONFIRM |
| http://seclists.org/fulldisclosure/2012/Apr/277 | mailing-listx_refsource_FULLDISC |
| http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A | x_refsource_MISC |
| http://arstechnica.com/business/news/2012/04/back… | x_refsource_MISC |
| http://www.securityfocus.com/bid/53215 | vdb-entryx_refsource_BID |
Date Public
2012-04-23 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:08:38.545Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "18779",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "http://www.exploit-db.com/exploits/18779"
},
{
"name": "ruggedcom-operating-system-backdoor(75120)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75120"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "http://archives.neohapsis.com/archives/bugtraq/2012-04/0186.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
},
{
"name": "53215",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/53215"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-04-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-12-13T18:57:01.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "18779",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "http://www.exploit-db.com/exploits/18779"
},
{
"name": "ruggedcom-operating-system-backdoor(75120)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75120"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "http://archives.neohapsis.com/archives/bugtraq/2012-04/0186.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
},
{
"name": "53215",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/53215"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-1803",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/",
"refsource": "MISC",
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "18779",
"refsource": "EXPLOIT-DB",
"url": "http://www.exploit-db.com/exploits/18779"
},
{
"name": "ruggedcom-operating-system-backdoor(75120)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75120"
},
{
"name": "VU#889195",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"refsource": "BUGTRAQ",
"url": "http://archives.neohapsis.com/archives/bugtraq/2012-04/0186.html"
},
{
"name": "http://www.ruggedcom.com/productbulletin/ros-security-page/",
"refsource": "CONFIRM",
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A"
},
{
"name": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars",
"refsource": "MISC",
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
},
{
"name": "53215",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/53215"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2012-1803",
"datePublished": "2012-04-28T00:00:00.000Z",
"dateReserved": "2012-03-21T00:00:00.000Z",
"dateUpdated": "2024-08-06T19:08:38.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-7836 (GCVE-0-2015-7836)
Vulnerability from cvelistv5 – Published: 2015-10-28 10:00 – Updated: 2024-08-06 07:59
VLAI
Summary
Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.siemens.com/cert/pool/cert/siemens_sec… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1033973 | vdb-entryx_refsource_SECTRACK |
| https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01 | x_refsource_MISC |
Date Public
2015-10-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T07:59:00.583Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf"
},
{
"name": "1033973",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033973"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-10-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-09-14T09:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf"
},
{
"name": "1033973",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1033973"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-7836",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-921524.pdf"
},
{
"name": "1033973",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1033973"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-300-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-7836",
"datePublished": "2015-10-28T10:00:00.000Z",
"dateReserved": "2015-10-15T00:00:00.000Z",
"dateUpdated": "2024-08-06T07:59:00.583Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-6675 (GCVE-0-2015-6675)
Vulnerability from cvelistv5 – Published: 2015-09-11 16:00 – Updated: 2024-08-06 07:29
VLAI
Summary
Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.siemens.com/cert/pool/cert/siemens_sec… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1033478 | vdb-entryx_refsource_SECTRACK |
| https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01 | x_refsource_MISC |
Date Public
2015-09-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T07:29:24.434Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf"
},
{
"name": "1033478",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033478"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-09-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-20T16:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf"
},
{
"name": "1033478",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1033478"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-6675",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-720081.pdf"
},
{
"name": "1033478",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1033478"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-244-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-6675",
"datePublished": "2015-09-11T16:00:00.000Z",
"dateReserved": "2015-08-26T00:00:00.000Z",
"dateUpdated": "2024-08-06T07:29:24.434Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-5537 (GCVE-0-2015-5537)
Vulnerability from cvelistv5 – Published: 2015-08-03 01:00 – Updated: 2024-08-06 06:50
VLAI
Summary
The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulnerability than CVE-2014-3566.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.securitytracker.com/id/1033022 | vdb-entryx_refsource_SECTRACK |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
| https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A | x_refsource_MISC |
Date Public
2015-07-21 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T06:50:02.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1033022",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033022"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-07-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulnerability than CVE-2014-3566."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-09-20T09:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "1033022",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1033022"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-5537",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulnerability than CVE-2014-3566."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1033022",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1033022"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-396873.pdf"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-03A"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-5537",
"datePublished": "2015-08-03T01:00:00.000Z",
"dateReserved": "2015-07-17T00:00:00.000Z",
"dateUpdated": "2024-08-06T06:50:02.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2590 (GCVE-0-2014-2590)
Vulnerability from cvelistv5 – Published: 2014-03-28 19:00 – Updated: 2024-08-06 10:21
VLAI
Summary
The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01 | x_refsource_MISC |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
Date Public
2014-03-28 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:21:35.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-03-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2014-03-28T19:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-2590",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-087-01"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-831997.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-2590",
"datePublished": "2014-03-28T19:00:00.000Z",
"dateReserved": "2014-03-24T00:00:00.000Z",
"dateUpdated": "2024-08-06T10:21:35.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-1966 (GCVE-0-2014-1966)
Vulnerability from cvelistv5 – Published: 2014-02-24 02:00 – Updated: 2024-08-06 09:58
VLAI
Summary
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
| http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03 | x_refsource_MISC |
Date Public
2014-02-20 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T09:58:15.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-02-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2014-02-24T02:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-1966",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892342.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-051-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-1966",
"datePublished": "2014-02-24T02:00:00.000Z",
"dateReserved": "2014-02-17T00:00:00.000Z",
"dateUpdated": "2024-08-06T09:58:15.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-6925 (GCVE-0-2013-6925)
Vulnerability from cvelistv5 – Published: 2013-12-17 02:00 – Updated: 2024-08-06 17:53
VLAI
Summary
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01 | x_refsource_MISC |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
Date Public
2013-12-06 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T17:53:44.793Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-12-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-12-17T02:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-6925",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-6925",
"datePublished": "2013-12-17T02:00:00.000Z",
"dateReserved": "2013-12-03T00:00:00.000Z",
"dateUpdated": "2024-08-06T17:53:44.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-6926 (GCVE-0-2013-6926)
Vulnerability from cvelistv5 – Published: 2013-12-17 02:00 – Updated: 2024-08-06 17:53
VLAI
Summary
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01 | x_refsource_MISC |
| http://www.siemens.com/innovation/pool/de/forschu… | x_refsource_CONFIRM |
Date Public
2013-12-06 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T17:53:45.172Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-12-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-12-17T02:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-6926",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-340-01"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-324789.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-6926",
"datePublished": "2013-12-17T02:00:00.000Z",
"dateReserved": "2013-12-03T00:00:00.000Z",
"dateUpdated": "2024-08-06T17:53:45.172Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-1803 (GCVE-0-2012-1803)
Vulnerability from cvelistv5 – Published: 2012-04-28 00:00 – Updated: 2024-08-06 19:08
VLAI
Summary
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
12 references
| URL | Tags |
|---|---|
| http://www.wired.com/threatlevel/2012/04/ruggedco… | x_refsource_MISC |
| http://www.exploit-db.com/exploits/18779 | exploitx_refsource_EXPLOIT-DB |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://www.kb.cert.org/vuls/id/889195 | third-party-advisoryx_refsource_CERT-VN |
| http://archives.neohapsis.com/archives/bugtraq/20… | mailing-listx_refsource_BUGTRAQ |
| http://www.ruggedcom.com/productbulletin/ros-secu… | x_refsource_CONFIRM |
| http://www.us-cert.gov/control_systems/pdf/ICS-AL… | x_refsource_MISC |
| http://www.kb.cert.org/vuls/id/MAPG-8RCPEN | x_refsource_CONFIRM |
| http://seclists.org/fulldisclosure/2012/Apr/277 | mailing-listx_refsource_FULLDISC |
| http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A | x_refsource_MISC |
| http://arstechnica.com/business/news/2012/04/back… | x_refsource_MISC |
| http://www.securityfocus.com/bid/53215 | vdb-entryx_refsource_BID |
Date Public
2012-04-23 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:08:38.545Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "18779",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "http://www.exploit-db.com/exploits/18779"
},
{
"name": "ruggedcom-operating-system-backdoor(75120)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75120"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "http://archives.neohapsis.com/archives/bugtraq/2012-04/0186.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
},
{
"name": "53215",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/53215"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-04-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-12-13T18:57:01.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "18779",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "http://www.exploit-db.com/exploits/18779"
},
{
"name": "ruggedcom-operating-system-backdoor(75120)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75120"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "http://archives.neohapsis.com/archives/bugtraq/2012-04/0186.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
},
{
"name": "53215",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/53215"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-1803",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/",
"refsource": "MISC",
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "18779",
"refsource": "EXPLOIT-DB",
"url": "http://www.exploit-db.com/exploits/18779"
},
{
"name": "ruggedcom-operating-system-backdoor(75120)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75120"
},
{
"name": "VU#889195",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"refsource": "BUGTRAQ",
"url": "http://archives.neohapsis.com/archives/bugtraq/2012-04/0186.html"
},
{
"name": "http://www.ruggedcom.com/productbulletin/ros-security-page/",
"refsource": "CONFIRM",
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/MAPG-8RCPEN"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-146-01A"
},
{
"name": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars",
"refsource": "MISC",
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
},
{
"name": "53215",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/53215"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2012-1803",
"datePublished": "2012-04-28T00:00:00.000Z",
"dateReserved": "2012-03-21T00:00:00.000Z",
"dateUpdated": "2024-08-06T19:08:38.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-2441 (GCVE-0-2012-2441)
Vulnerability from cvelistv5 – Published: 2012-04-28 00:00 – Updated: 2024-08-06 19:34
VLAI
Summary
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
7 references
| URL | Tags |
|---|---|
| http://www.wired.com/threatlevel/2012/04/ruggedco… | x_refsource_MISC |
| http://www.kb.cert.org/vuls/id/889195 | third-party-advisoryx_refsource_CERT-VN |
| http://www.ruggedcom.com/productbulletin/ros-secu… | x_refsource_CONFIRM |
| http://www.us-cert.gov/control_systems/pdf/ICS-AL… | x_refsource_MISC |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://seclists.org/fulldisclosure/2012/Apr/277 | mailing-listx_refsource_FULLDISC |
| http://arstechnica.com/business/news/2012/04/back… | x_refsource_MISC |
Date Public
2012-04-27 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:34:25.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "ruggedcom-unauth-access(75244)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75244"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-04-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-12-13T18:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "VU#889195",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "ruggedcom-unauth-access(75244)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75244"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-2441",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/",
"refsource": "MISC",
"url": "http://www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/"
},
{
"name": "VU#889195",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/889195"
},
{
"name": "http://www.ruggedcom.com/productbulletin/ros-security-page/",
"refsource": "CONFIRM",
"url": "http://www.ruggedcom.com/productbulletin/ros-security-page/"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf"
},
{
"name": "ruggedcom-unauth-access(75244)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75244"
},
{
"name": "20120423 RuggedCom - Backdoor Accounts in my SCADA network? You don\u0027t say...",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2012/Apr/277"
},
{
"name": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars",
"refsource": "MISC",
"url": "http://arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-power-traffic-control-systems.ars"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-2441",
"datePublished": "2012-04-28T00:00:00.000Z",
"dateReserved": "2012-04-27T00:00:00.000Z",
"dateUpdated": "2024-08-06T19:34:25.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}