CVE-2023-36755 (GCVE-0-2023-36755)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-19 16:30
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.103Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36755",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-19T16:25:28.010364Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-19T16:30:23.659Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:22.285Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36755",
"datePublished": "2023-07-11T09:07:22.285Z",
"dateReserved": "2023-06-27T11:37:08.704Z",
"dateUpdated": "2024-11-19T16:30:23.659Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36754 (GCVE-0-2023-36754)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-12-10 17:04
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP server configuration URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36754",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T17:04:20.520881Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:04:35.432Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The SCEP server configuration URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:21.194Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36754",
"datePublished": "2023-07-11T09:07:21.194Z",
"dateReserved": "2023-06-27T11:37:08.704Z",
"dateUpdated": "2024-12-10T17:04:35.432Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36753 (GCVE-0-2023-36753)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-12-02 18:56
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The uninstall-app App-name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.239Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36753",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T18:50:15.983427Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T18:56:24.844Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The uninstall-app App-name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:20.117Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36753",
"datePublished": "2023-07-11T09:07:20.117Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-12-02T18:56:24.844Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36752 (GCVE-0-2023-36752)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-20 20:30
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The upgrade-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.242Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36752",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T20:25:17.463714Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T20:30:40.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The upgrade-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:19.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36752",
"datePublished": "2023-07-11T09:07:19.000Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-20T20:30:40.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36751 (GCVE-0-2023-36751)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-26 16:42
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.455Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36751",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T16:36:23.343532Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T16:42:01.446Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:17.921Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36751",
"datePublished": "2023-07-11T09:07:17.921Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-26T16:42:01.446Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36750 (GCVE-0-2023-36750)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-26 18:40
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The software-upgrade Url parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.252Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36750",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T18:35:58.218652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T18:40:24.816Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The software-upgrade Url parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:16.822Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36750",
"datePublished": "2023-07-11T09:07:16.822Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-26T18:40:24.816Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36749 (GCVE-0-2023-36749)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-27 14:15
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The webserver of the affected devices support insecure TLS 1.0 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.
Severity ?
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.156Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36749",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T13:57:48.336400Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T14:15:10.273Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The webserver of the affected devices support insecure TLS 1.0 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:15.754Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36749",
"datePublished": "2023-07-11T09:07:15.754Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-27T14:15:10.273Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36748 (GCVE-0-2023-36748)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-27 14:16
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The affected devices are configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data
passed over to and from the affected device.
Severity ?
CWE
- CWE-326 - Inadequate Encryption Strength
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.437Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36748",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T14:16:24.794778Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T14:16:46.630Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The affected devices are configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over to and from the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:14.689Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36748",
"datePublished": "2023-07-11T09:07:14.689Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-27T14:16:46.630Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36390 (GCVE-0-2023-36390)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-10-21 21:10
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response
without sanitization while throwing an “invalid params element name” error on the action parameters.
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:45:56.373Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36390",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:50.284040Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:10:21.036Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response\r\nwithout sanitization while throwing an \u201cinvalid params element name\u201d error on the action parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:12.557Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36390",
"datePublished": "2023-07-11T09:07:12.557Z",
"dateReserved": "2023-06-21T14:46:26.354Z",
"dateUpdated": "2024-10-21T21:10:21.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36389 (GCVE-0-2023-36389)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-10-21 21:10
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The malformed value is reflected
directly in the response without sanitization while throwing an “invalid path” error.
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:45:56.382Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36389",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:51.541223Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:10:27.428Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The malformed value is reflected\r\ndirectly in the response without sanitization while throwing an \u201cinvalid path\u201d error."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:11.475Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36389",
"datePublished": "2023-07-11T09:07:11.475Z",
"dateReserved": "2023-06-21T14:31:54.523Z",
"dateUpdated": "2024-10-21T21:10:27.428Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36386 (GCVE-0-2023-36386)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-10-21 21:10
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an
“invalid params element name” error on the get_elements parameters.
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:45:56.712Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36386",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:52.736344Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:10:35.826Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an\r\n\u201cinvalid params element name\u201d error on the get_elements parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:10.369Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36386",
"datePublished": "2023-07-11T09:07:10.369Z",
"dateReserved": "2023-06-21T13:10:13.218Z",
"dateUpdated": "2024-10-21T21:10:35.826Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-29562 (GCVE-0-2022-29562)
Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-12 16:17
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). Affected devices do not properly handle malformed HTTP packets. This could allow an unauthenticated remote attacker to send a malformed HTTP packet causing certain functions to fail in a controlled manner.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:26:06.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-29562",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T16:17:25.427826Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T16:17:46.868Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). Affected devices do not properly handle malformed HTTP packets. This could allow an unauthenticated remote attacker to send a malformed HTTP packet causing certain functions to fail in a controlled manner."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:00.397Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-29562",
"datePublished": "2023-07-11T09:07:00.397Z",
"dateReserved": "2022-04-21T13:34:15.980Z",
"dateUpdated": "2024-11-12T16:17:46.868Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-29561 (GCVE-0-2022-29561)
Vulnerability from nvd – Published: 2023-07-11 09:06 – Updated: 2024-11-12 19:11
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
Severity ?
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:26:05.943Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-29561",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T19:06:12.746479Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T19:11:46.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352: Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:06:58.988Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-29561",
"datePublished": "2023-07-11T09:06:58.988Z",
"dateReserved": "2022-04-21T13:34:15.980Z",
"dateUpdated": "2024-11-12T19:11:46.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-29560 (GCVE-0-2022-29560)
Vulnerability from nvd – Published: 2022-07-12 10:06 – Updated: 2024-08-03 06:26
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < 2.15.1), RUGGEDCOM ROX MX5000RE (All versions < 2.15.1), RUGGEDCOM ROX RX1400 (All versions < 2.15.1), RUGGEDCOM ROX RX1500 (All versions < 2.15.1), RUGGEDCOM ROX RX1501 (All versions < 2.15.1), RUGGEDCOM ROX RX1510 (All versions < 2.15.1), RUGGEDCOM ROX RX1511 (All versions < 2.15.1), RUGGEDCOM ROX RX1512 (All versions < 2.15.1), RUGGEDCOM ROX RX1524 (All versions < 2.15.1), RUGGEDCOM ROX RX1536 (All versions < 2.15.1), RUGGEDCOM ROX RX5000 (All versions < 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user.
Severity ?
No CVSS data available.
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < 2.15.1
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:26:06.278Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c 2.15.1), RUGGEDCOM ROX MX5000RE (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1400 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1500 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1501 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1510 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1511 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1512 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1524 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1536 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX5000 (All versions \u003c 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-12T10:06:38",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-29560",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM ROX MX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX MX5000RE",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1400",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1500",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1501",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1510",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1511",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1512",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1524",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1536",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c 2.15.1), RUGGEDCOM ROX MX5000RE (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1400 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1500 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1501 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1510 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1511 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1512 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1524 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1536 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX5000 (All versions \u003c 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-29560",
"datePublished": "2022-07-12T10:06:38",
"dateReserved": "2022-04-21T00:00:00",
"dateUpdated": "2024-08-03T06:26:06.278Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41546 (GCVE-0-2021-41546)
Vulnerability from nvd – Published: 2021-10-12 09:49 – Updated: 2024-08-04 03:15
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service.
Severity ?
No CVSS data available.
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.14.1
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:15:28.882Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-12T09:49:39",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-41546",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM ROX MX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1400",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1500",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1501",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1510",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1511",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1512",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1524",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1536",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-41546",
"datePublished": "2021-10-12T09:49:39",
"dateReserved": "2021-09-21T00:00:00",
"dateUpdated": "2024-08-04T03:15:28.882Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36755 (GCVE-0-2023-36755)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-19 16:30
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.103Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36755",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-19T16:25:28.010364Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-19T16:30:23.659Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:22.285Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36755",
"datePublished": "2023-07-11T09:07:22.285Z",
"dateReserved": "2023-06-27T11:37:08.704Z",
"dateUpdated": "2024-11-19T16:30:23.659Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36754 (GCVE-0-2023-36754)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-12-10 17:04
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP server configuration URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36754",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T17:04:20.520881Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:04:35.432Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The SCEP server configuration URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:21.194Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36754",
"datePublished": "2023-07-11T09:07:21.194Z",
"dateReserved": "2023-06-27T11:37:08.704Z",
"dateUpdated": "2024-12-10T17:04:35.432Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36753 (GCVE-0-2023-36753)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-12-02 18:56
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The uninstall-app App-name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.239Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36753",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T18:50:15.983427Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T18:56:24.844Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The uninstall-app App-name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:20.117Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36753",
"datePublished": "2023-07-11T09:07:20.117Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-12-02T18:56:24.844Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36752 (GCVE-0-2023-36752)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-20 20:30
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The upgrade-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.242Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36752",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T20:25:17.463714Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T20:30:40.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The upgrade-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:19.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36752",
"datePublished": "2023-07-11T09:07:19.000Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-20T20:30:40.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36751 (GCVE-0-2023-36751)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-26 16:42
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.455Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36751",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T16:36:23.343532Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T16:42:01.446Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:17.921Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36751",
"datePublished": "2023-07-11T09:07:17.921Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-26T16:42:01.446Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36750 (GCVE-0-2023-36750)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-26 18:40
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The software-upgrade Url parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Severity ?
9.1 (Critical)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.252Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36750",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T18:35:58.218652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T18:40:24.816Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The software-upgrade Url parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:16.822Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36750",
"datePublished": "2023-07-11T09:07:16.822Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-26T18:40:24.816Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36749 (GCVE-0-2023-36749)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-27 14:15
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The webserver of the affected devices support insecure TLS 1.0 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.
Severity ?
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.156Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36749",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T13:57:48.336400Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T14:15:10.273Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The webserver of the affected devices support insecure TLS 1.0 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:15.754Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36749",
"datePublished": "2023-07-11T09:07:15.754Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-27T14:15:10.273Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36748 (GCVE-0-2023-36748)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-27 14:16
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The affected devices are configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data
passed over to and from the affected device.
Severity ?
CWE
- CWE-326 - Inadequate Encryption Strength
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:52:54.437Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36748",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T14:16:24.794778Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T14:16:46.630Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The affected devices are configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over to and from the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:14.689Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36748",
"datePublished": "2023-07-11T09:07:14.689Z",
"dateReserved": "2023-06-27T11:37:08.703Z",
"dateUpdated": "2024-11-27T14:16:46.630Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36390 (GCVE-0-2023-36390)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-10-21 21:10
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response
without sanitization while throwing an “invalid params element name” error on the action parameters.
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:45:56.373Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36390",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:50.284040Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:10:21.036Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response\r\nwithout sanitization while throwing an \u201cinvalid params element name\u201d error on the action parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:12.557Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36390",
"datePublished": "2023-07-11T09:07:12.557Z",
"dateReserved": "2023-06-21T14:46:26.354Z",
"dateUpdated": "2024-10-21T21:10:21.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36389 (GCVE-0-2023-36389)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-10-21 21:10
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The malformed value is reflected
directly in the response without sanitization while throwing an “invalid path” error.
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:45:56.382Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36389",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:51.541223Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:10:27.428Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The malformed value is reflected\r\ndirectly in the response without sanitization while throwing an \u201cinvalid path\u201d error."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:11.475Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36389",
"datePublished": "2023-07-11T09:07:11.475Z",
"dateReserved": "2023-06-21T14:31:54.523Z",
"dateUpdated": "2024-10-21T21:10:27.428Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-36386 (GCVE-0-2023-36386)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-10-21 21:10
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an
“invalid params element name” error on the get_elements parameters.
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:45:56.712Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-36386",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:52.736344Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:10:35.826Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an\r\n\u201cinvalid params element name\u201d error on the get_elements parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:10.369Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-36386",
"datePublished": "2023-07-11T09:07:10.369Z",
"dateReserved": "2023-06-21T13:10:13.218Z",
"dateUpdated": "2024-10-21T21:10:35.826Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-29562 (GCVE-0-2022-29562)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-12 16:17
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). Affected devices do not properly handle malformed HTTP packets. This could allow an unauthenticated remote attacker to send a malformed HTTP packet causing certain functions to fail in a controlled manner.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:26:06.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-29562",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T16:17:25.427826Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T16:17:46.868Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). Affected devices do not properly handle malformed HTTP packets. This could allow an unauthenticated remote attacker to send a malformed HTTP packet causing certain functions to fail in a controlled manner."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:07:00.397Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-29562",
"datePublished": "2023-07-11T09:07:00.397Z",
"dateReserved": "2022-04-21T13:34:15.980Z",
"dateUpdated": "2024-11-12T16:17:46.868Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-29561 (GCVE-0-2022-29561)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:06 – Updated: 2024-11-12 19:11
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
Severity ?
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.16.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:26:05.943Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_mx5000re",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1400",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1500",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1501",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2.16.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1510",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1511",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1512",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1524",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx1536",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ruggedcom_rox_rx5000",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V2.16.0"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-29561",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T19:06:12.746479Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T19:11:46.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.16.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352: Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-11T09:06:58.988Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-29561",
"datePublished": "2023-07-11T09:06:58.988Z",
"dateReserved": "2022-04-21T13:34:15.980Z",
"dateUpdated": "2024-11-12T19:11:46.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-29560 (GCVE-0-2022-29560)
Vulnerability from cvelistv5 – Published: 2022-07-12 10:06 – Updated: 2024-08-03 06:26
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < 2.15.1), RUGGEDCOM ROX MX5000RE (All versions < 2.15.1), RUGGEDCOM ROX RX1400 (All versions < 2.15.1), RUGGEDCOM ROX RX1500 (All versions < 2.15.1), RUGGEDCOM ROX RX1501 (All versions < 2.15.1), RUGGEDCOM ROX RX1510 (All versions < 2.15.1), RUGGEDCOM ROX RX1511 (All versions < 2.15.1), RUGGEDCOM ROX RX1512 (All versions < 2.15.1), RUGGEDCOM ROX RX1524 (All versions < 2.15.1), RUGGEDCOM ROX RX1536 (All versions < 2.15.1), RUGGEDCOM ROX RX5000 (All versions < 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user.
Severity ?
No CVSS data available.
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < 2.15.1
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:26:06.278Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 2.15.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c 2.15.1), RUGGEDCOM ROX MX5000RE (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1400 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1500 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1501 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1510 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1511 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1512 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1524 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1536 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX5000 (All versions \u003c 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-12T10:06:38",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-29560",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM ROX MX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX MX5000RE",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1400",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1500",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1501",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1510",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1511",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1512",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1524",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1536",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 2.15.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c 2.15.1), RUGGEDCOM ROX MX5000RE (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1400 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1500 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1501 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1510 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1511 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1512 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1524 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX1536 (All versions \u003c 2.15.1), RUGGEDCOM ROX RX5000 (All versions \u003c 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-29560",
"datePublished": "2022-07-12T10:06:38",
"dateReserved": "2022-04-21T00:00:00",
"dateUpdated": "2024-08-03T06:26:06.278Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41546 (GCVE-0-2021-41546)
Vulnerability from cvelistv5 – Published: 2021-10-12 09:49 – Updated: 2024-08-04 03:15
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service.
Severity ?
No CVSS data available.
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.14.1
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:15:28.882Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-12T09:49:39",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-41546",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM ROX MX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1400",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1500",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1501",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1510",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1511",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1512",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1524",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1536",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-41546",
"datePublished": "2021-10-12T09:49:39",
"dateReserved": "2021-09-21T00:00:00",
"dateUpdated": "2024-08-04T03:15:28.882Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}