Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for roc809_firmware by emerson

    CVE-2023-1935 (GCVE-0-2023-1935)

    Vulnerability from nvd – Published: 2023-08-02 22:40 – Updated: 2024-10-21 18:57
    VLAI
    Title
    CVE-2023-1935
    Summary
    ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T06:05:26.782Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1935",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-21T18:57:37.798124Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-21T18:57:56.089Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "DL8000",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC827",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC809L",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC827",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC809",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-305",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-02T22:40:46.883Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "CVE-2023-1935",
          "x_generator": {
            "engine": "VINCE 2.1.3",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-1935"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-1935",
        "datePublished": "2023-08-02T22:40:46.883Z",
        "dateReserved": "2023-04-07T00:02:59.470Z",
        "dateUpdated": "2024-10-21T18:57:56.089Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-30264 (GCVE-0-2022-30264)

    Vulnerability from nvd – Published: 2022-08-16 12:42 – Updated: 2024-08-03 06:40
    VLAI
    Summary
    The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T06:40:47.846Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.forescout.com/blog/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-16T12:42:57.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.forescout.com/blog/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-30264",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.forescout.com/blog/",
                  "refsource": "MISC",
                  "url": "https://www.forescout.com/blog/"
                },
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-30264",
        "datePublished": "2022-08-16T12:42:58.000Z",
        "dateReserved": "2022-05-04T00:00:00.000Z",
        "dateUpdated": "2024-08-03T06:40:47.846Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-1935 (GCVE-0-2023-1935)

    Vulnerability from cvelistv5 – Published: 2023-08-02 22:40 – Updated: 2024-10-21 18:57
    VLAI
    Title
    CVE-2023-1935
    Summary
    ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T06:05:26.782Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1935",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-21T18:57:37.798124Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-21T18:57:56.089Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "DL8000",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC827",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC809L",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC827",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            },
            {
              "product": "ROC809",
              "vendor": "Emerson Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-305",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-02T22:40:46.883Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "CVE-2023-1935",
          "x_generator": {
            "engine": "VINCE 2.1.3",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-1935"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-1935",
        "datePublished": "2023-08-02T22:40:46.883Z",
        "dateReserved": "2023-04-07T00:02:59.470Z",
        "dateUpdated": "2024-10-21T18:57:56.089Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-30264 (GCVE-0-2022-30264)

    Vulnerability from cvelistv5 – Published: 2022-08-16 12:42 – Updated: 2024-08-03 06:40
    VLAI
    Summary
    The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T06:40:47.846Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.forescout.com/blog/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-16T12:42:57.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.forescout.com/blog/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-30264",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.forescout.com/blog/",
                  "refsource": "MISC",
                  "url": "https://www.forescout.com/blog/"
                },
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-30264",
        "datePublished": "2022-08-16T12:42:58.000Z",
        "dateReserved": "2022-05-04T00:00:00.000Z",
        "dateUpdated": "2024-08-03T06:40:47.846Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }