Search

Find a vulnerability

Search criteria

    3 vulnerabilities found for r500 by ruckuswireless

    VAR-202301-1662

    Vulnerability from variot - Updated: 2025-04-04 23:31

    In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to change and set unauthorized "illegal region code" by remote code Execution command injection which leads to run illegal frequency with maxi output power. Vulnerability allows attacker to create an arbitrary amount of ssid wlans interface per radio which creates overhead over noise (the default max limit is 8 ssid only per radio in solo AP). Vulnerability allows attacker to unlock hidden regions by privilege command injection in WEB GUI. plural Ruckus Networks ( Old Ruckus Wireless, Inc.) Contains a command injection vulnerability.Information may be tampered with

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202301-1662",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "zonedirector 1100",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.10.2.0.130"
          },
          {
            "model": "t301s",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "r500",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "r310",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "r600",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "t301n",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "zonedirector 3000",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.2.1.0.218"
          },
          {
            "model": "sz-100",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "t300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "sz-300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "zonedirector 5000",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.0.1.0.151"
          },
          {
            "model": "scg200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "zonedirector 1200",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.2.1.0.218"
          },
          {
            "model": "vsz",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "vsz",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "zonedirector 3000",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "sz-100",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "t300",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "r310",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "r600",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "zonedirector 5000",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "r500",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "zonedirector 1100",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "scg200",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "cve": "CVE-2020-22662",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-22662",
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2020-22662",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-22662",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2020-22662",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-22662",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202301-1621",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to change and set unauthorized \"illegal region code\" by remote code Execution command injection which leads to run illegal frequency with maxi output power. Vulnerability allows attacker to create an arbitrary amount of ssid wlans interface per radio which creates overhead over noise (the default max limit is 8 ssid only per radio in solo AP). Vulnerability allows attacker to unlock hidden regions by privilege command injection in WEB GUI. plural Ruckus Networks ( Old Ruckus Wireless, Inc.) Contains a command injection vulnerability.Information may be tampered with",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22662"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-22662",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621",
            "trust": 0.6
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22662",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22662"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "id": "VAR-202301-1662",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ],
        "trust": 0.01
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "network device"
            ],
            "sub_category": "access point",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ]
      },
      "last_update_date": "2025-04-04T23:31:31.610000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Bulletin\u00a020200302",
            "trust": 0.8,
            "url": "https://support.ruckuswireless.com/security_bulletins/302"
          },
          {
            "title": "Ruckus Networks Repair measures for command injection vulnerabilities in multiple products",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=223507"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://support.ruckuswireless.com/security_bulletins/302"
          },
          {
            "trust": 1.0,
            "url": "https://hdhrmi.blogspot.com/2020/03/multiple-vulnerabilities-in-ruckus.html?m=1"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-22662"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2020-22662/"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22662"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22662"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-01-20T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-22662"
          },
          {
            "date": "2023-07-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "date": "2023-01-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          },
          {
            "date": "2023-01-20T19:15:13.063000",
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-01-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-22662"
          },
          {
            "date": "2023-07-11T06:53:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          },
          {
            "date": "2023-02-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          },
          {
            "date": "2025-04-03T18:15:40.630000",
            "db": "NVD",
            "id": "CVE-2020-22662"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0Ruckus\u00a0Networks\u00a0( Old \u00a0Ruckus\u00a0Wireless,\u00a0Inc.)\u00a0 Command injection vulnerabilities in the product",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017630"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1621"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202301-1812

    Vulnerability from variot - Updated: 2025-04-04 22:36

    R310 firmware, R500 firmware, R600 firmware etc. Ruckus Networks ( Old Ruckus Wireless, Inc.) The product contains authentication vulnerabilities.Information may be obtained and information may be tampered with.

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202301-1812",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "zonedirector 1100",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.10.2.0.130"
          },
          {
            "model": "t301s",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "r500",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "r310",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "r600",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "t301n",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "zonedirector 3000",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.2.1.0.218"
          },
          {
            "model": "sz-100",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "t300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.5.1.0.199"
          },
          {
            "model": "sz-300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "zonedirector 5000",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.0.1.0.151"
          },
          {
            "model": "scg200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "zonedirector 1200",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.2.1.0.218"
          },
          {
            "model": "vsz",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "3.6.2.0.795"
          },
          {
            "model": "t301s",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "sz-300",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "r310",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "scg200",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "t300",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "r600",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "t301n",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "sz-100",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "r500",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          },
          {
            "model": "vsz",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus \u65e7 ruckus",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "cve": "CVE-2020-22657",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-22657",
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 9.1,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-22657",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-22657",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2020-22657",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-22657",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202301-1629",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22657"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "R310 firmware, R500 firmware, R600 firmware etc. Ruckus Networks ( Old Ruckus Wireless, Inc.) The product contains authentication vulnerabilities.Information may be obtained and information may be tampered with.",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          }
        ],
        "trust": 0.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-22657",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629",
            "trust": 0.6
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22657",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22657"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "id": "VAR-202301-1812",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ],
        "trust": 0.01
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "network device"
            ],
            "sub_category": "gateway",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ]
      },
      "last_update_date": "2025-04-04T22:36:42.625000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Ruckus Networks Unleashed C110 Remediation measures for authorization problem vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=223297"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-287",
            "trust": 1.0
          },
          {
            "problemtype": "Inappropriate authentication (CWE-287) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://support.ruckuswireless.com/security_bulletins/302"
          },
          {
            "trust": 1.0,
            "url": "https://hdhrmi.blogspot.com/2020/03/multiple-vulnerabilities-in-ruckus.html?m=1"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-22657"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2020-22657/"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22657"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-22657"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-01-20T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-22657"
          },
          {
            "date": "2023-07-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "date": "2023-01-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          },
          {
            "date": "2023-01-20T19:15:12.787000",
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-01-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-22657"
          },
          {
            "date": "2023-07-05T08:12:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          },
          {
            "date": "2023-02-01T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          },
          {
            "date": "2025-04-03T18:15:39.810000",
            "db": "NVD",
            "id": "CVE-2020-22657"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0Ruckus\u00a0Networks\u00a0( Old \u00a0Ruckus\u00a0Wireless,\u00a0Inc.)\u00a0 Product certification vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017615"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202301-1629"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201802-0642

    Vulnerability from variot - Updated: 2024-11-23 23:08

    Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems. Both Ruckus Networks Unleashed AP and Ruckus Networks Zone Director are wireless access points from Ruckus Wireless. A remote attacker could exploit this vulnerability to execute privileged commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201802-0642",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "zonedirector 1200",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "ruckuswireless",
            "version": "10.1.0.0.1515"
          },
          {
            "model": "zonedirector 3000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "ruckuswireless",
            "version": "10.1.0.0.1515"
          },
          {
            "model": "zonedirector 3000",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.12.3.0.28"
          },
          {
            "model": "t300e",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "zonedirector 1200",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.13.3.0.22"
          },
          {
            "model": "t301",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "r710",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "r500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "t710",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "r310",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "h510",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "r600",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "zonedirector 1200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.13.3.0.145"
          },
          {
            "model": "zonedirector 3000",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.10.2.0.53"
          },
          {
            "model": "zonedirector 1200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.12.3.0.83"
          },
          {
            "model": "zonedirector 3000",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.0.1.0.44"
          },
          {
            "model": "t300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "zonedirector 1200",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.0.1.0.17"
          },
          {
            "model": "zonedirector 1200",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.10.2.0.11"
          },
          {
            "model": "t610",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "zonedirector 3000",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.13.3.0.22"
          },
          {
            "model": "r720",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "r510",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "zonedirector 3000",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.0.1.0.17"
          },
          {
            "model": "zonedirector 3000",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.10.2.0.11"
          },
          {
            "model": "zonedirector 1200",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.12.3.0.28"
          },
          {
            "model": "h320",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "200.6.10.1.0"
          },
          {
            "model": "zonedirector 1200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "10.0.1.0.44"
          },
          {
            "model": "zonedirector 1200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.10.2.0.53"
          },
          {
            "model": "zonedirector 3000",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.13.3.0.145"
          },
          {
            "model": "zonedirector 3000",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "ruckuswireless",
            "version": "9.12.3.0.83"
          },
          {
            "model": "h320",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "h510",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "r310",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "r500",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "r510",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "r600",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "r710",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "r720",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "t300",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "t300e",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "t301",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "t610",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "t710",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "zonedirector 1200",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          },
          {
            "model": "zonedirector 3000",
            "scope": null,
            "trust": 0.8,
            "vendor": "ruckus",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:h320_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:h510_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:r310_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:r500_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:r510_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:r600_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:r710_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:r720_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:t300_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:t300e_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:t301_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:t610_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:t710_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:zonedirector_1200_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:ruckus_wireless:zonedirector_3000_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          }
        ]
      },
      "cve": "CVE-2017-6229",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2017-6229",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "VHN-114432",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2017-6229",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-6229",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-6229",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201802-916",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-114432",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-114432"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems. Both Ruckus Networks Unleashed AP and Ruckus Networks Zone Director are wireless access points from Ruckus Wireless. A remote attacker could exploit this vulnerability to execute privileged commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-6229"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "db": "VULHUB",
            "id": "VHN-114432"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-6229",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-114432",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-114432"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "id": "VAR-201802-0642",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-114432"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T23:08:46.893000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Authenticated Root Command Injection Vulnerabilities in CLI of ZD/Unleashed APs and Web-GUI of Solo/SZ Managed APs (CVE-2017-6229, CVE2017-6230)",
            "trust": 0.8,
            "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-114432"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6229"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-6229"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-114432"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-114432"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-02-14T00:00:00",
            "db": "VULHUB",
            "id": "VHN-114432"
          },
          {
            "date": "2018-03-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "date": "2018-02-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          },
          {
            "date": "2018-02-14T19:29:00.213000",
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-03-12T00:00:00",
            "db": "VULHUB",
            "id": "VHN-114432"
          },
          {
            "date": "2018-03-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          },
          {
            "date": "2018-08-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          },
          {
            "date": "2024-11-21T03:29:18.477000",
            "db": "NVD",
            "id": "CVE-2017-6229"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Ruckus Networks Unleashed AP and  Zone Director In firmware  OS Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-012629"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-916"
          }
        ],
        "trust": 0.6
      }
    }