Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for pt7135_firmware by vivotek

    CVE-2013-1598 (GCVE-0-2013-1598)

    Vulnerability from nvd – Published: 2020-01-24 18:32 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.475Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59575"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T18:32:07.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59575"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1598",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59575",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59575"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1598",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1598",
        "datePublished": "2020-01-24T18:32:07.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.475Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1597 (GCVE-0-2013-1597)

    Vulnerability from nvd – Published: 2020-01-24 18:08 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59576"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1597"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T18:08:12.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59576"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1597"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1597",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59576",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59576"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1597",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1597"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1597",
        "datePublished": "2020-01-24T18:08:12.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1596 (GCVE-0-2013-1596)

    Vulnerability from nvd – Published: 2020-01-24 17:53 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.322Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59574"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1596"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T17:53:10.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59574"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1596"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1596",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59574",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59574"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1596",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1596"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1596",
        "datePublished": "2020-01-24T17:53:10.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.322Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1595 (GCVE-0-2013-1595)

    Vulnerability from nvd – Published: 2020-01-24 17:10 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59573"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1595"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T17:39:57.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59573"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1595"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1595",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59573",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59573"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1595",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1595"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1595",
        "datePublished": "2020-01-24T17:10:08.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1594 (GCVE-0-2013-1594)

    Vulnerability from nvd – Published: 2020-01-24 16:59 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    An Information Disclosure vulnerability exists via a GET request in Vivotek PT7135 IP Camera 0300a and 0400a due to wireless keys and 3rd party credentials stored in clear text.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.521Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59572"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/25139"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1594"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Information Disclosure vulnerability exists via a GET request in Vivotek PT7135 IP Camera 0300a and 0400a due to wireless keys and 3rd party credentials stored in clear text."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T16:59:42.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59572"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.exploit-db.com/exploits/25139"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1594"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1594",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Information Disclosure vulnerability exists via a GET request in Vivotek PT7135 IP Camera 0300a and 0400a due to wireless keys and 3rd party credentials stored in clear text."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59572",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59572"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943"
                },
                {
                  "name": "http://www.exploit-db.com/exploits/25139",
                  "refsource": "MISC",
                  "url": "http://www.exploit-db.com/exploits/25139"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1594",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1594"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1594",
        "datePublished": "2020-01-24T16:59:42.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.521Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1598 (GCVE-0-2013-1598)

    Vulnerability from cvelistv5 – Published: 2020-01-24 18:32 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.475Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59575"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T18:32:07.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59575"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1598",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59575",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59575"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1598",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1598",
        "datePublished": "2020-01-24T18:32:07.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.475Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1597 (GCVE-0-2013-1597)

    Vulnerability from cvelistv5 – Published: 2020-01-24 18:08 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59576"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1597"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T18:08:12.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59576"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1597"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1597",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59576",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59576"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83947"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1597",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1597"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1597",
        "datePublished": "2020-01-24T18:08:12.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1596 (GCVE-0-2013-1596)

    Vulnerability from cvelistv5 – Published: 2020-01-24 17:53 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.322Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59574"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1596"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T17:53:10.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59574"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1596"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1596",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59574",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59574"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83945"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1596",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1596"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1596",
        "datePublished": "2020-01-24T17:53:10.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.322Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1595 (GCVE-0-2013-1595)

    Vulnerability from cvelistv5 – Published: 2020-01-24 17:10 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59573"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1595"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T17:39:57.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59573"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1595"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1595",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59573",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59573"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83944"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1595",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1595"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1595",
        "datePublished": "2020-01-24T17:10:08.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-1594 (GCVE-0-2013-1594)

    Vulnerability from cvelistv5 – Published: 2020-01-24 16:59 – Updated: 2024-08-06 15:04
    VLAI
    Summary
    An Information Disclosure vulnerability exists via a GET request in Vivotek PT7135 IP Camera 0300a and 0400a due to wireless keys and 3rd party credentials stored in clear text.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-04-29 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:04:49.521Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/59572"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/25139"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1594"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-04-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Information Disclosure vulnerability exists via a GET request in Vivotek PT7135 IP Camera 0300a and 0400a due to wireless keys and 3rd party credentials stored in clear text."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-24T16:59:42.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.securityfocus.com/bid/59572"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.exploit-db.com/exploits/25139"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1594"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-1594",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Information Disclosure vulnerability exists via a GET request in Vivotek PT7135 IP Camera 0300a and 0400a due to wireless keys and 3rd party credentials stored in clear text."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.securityfocus.com/bid/59572",
                  "refsource": "MISC",
                  "url": "http://www.securityfocus.com/bid/59572"
                },
                {
                  "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943",
                  "refsource": "MISC",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83943"
                },
                {
                  "name": "http://www.exploit-db.com/exploits/25139",
                  "refsource": "MISC",
                  "url": "http://www.exploit-db.com/exploits/25139"
                },
                {
                  "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
                },
                {
                  "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1594",
                  "refsource": "MISC",
                  "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1594"
                },
                {
                  "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
                  "refsource": "MISC",
                  "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-1594",
        "datePublished": "2020-01-24T16:59:42.000Z",
        "dateReserved": "2013-02-04T00:00:00.000Z",
        "dateUpdated": "2024-08-06T15:04:49.521Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }