Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for prosyst_mbs_sdk by bosch

    CVE-2019-11603 (GCVE-0-2019-11603)

    Vulnerability from nvd – Published: 2019-08-21 19:29 – Updated: 2024-09-16 23:46
    VLAI
    Title
    Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:55:41.027Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T19:29:23.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11603",
              "STATE": "PUBLIC",
              "TITLE": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-11603",
        "datePublished": "2019-08-21T19:29:23.032Z",
        "dateReserved": "2019-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:46:18.811Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11602 (GCVE-0-2019-11602)

    Vulnerability from nvd – Published: 2019-08-21 19:21 – Updated: 2024-09-17 00:56
    VLAI
    Title
    Leakage of stack traces in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    Leakage of stack traces in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:55:41.050Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T19:21:38.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11602",
              "STATE": "PUBLIC",
              "TITLE": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-11602",
        "datePublished": "2019-08-21T19:21:38.452Z",
        "dateReserved": "2019-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:56:40.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11601 (GCVE-0-2019-11601)

    Vulnerability from nvd – Published: 2019-08-21 19:09 – Updated: 2024-09-16 17:59
    VLAI
    Title
    Path traversal in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    A directory traversal vulnerability in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:55:41.059Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T19:09:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11601",
              "STATE": "PUBLIC",
              "TITLE": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-11601",
        "datePublished": "2019-08-21T19:09:01.029Z",
        "dateReserved": "2019-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:59:22.845Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11897 (GCVE-0-2019-11897)

    Vulnerability from nvd – Published: 2019-08-21 17:09 – Updated: 2024-09-17 03:55
    VLAI
    Title
    Server-side request forgery in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    A Server-Side Request Forgery (SSRF) vulnerability in the backup & restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server.
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bosch IoT Gateway Software Affected: unspecified , < 9.3.0 (custom)
    Create a notification for this product.
    ProSyst mBS SDK Affected: unspecified , < 8.2.6 (custom)
    Create a notification for this product.
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:10:29.663Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "IoT Gateway Software",
              "vendor": "Bosch",
              "versions": [
                {
                  "lessThan": "9.3.0",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mBS SDK",
              "vendor": "ProSyst",
              "versions": [
                {
                  "lessThan": "8.2.6",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "CWE-918 Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T17:09:52.000Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.6"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@bosch.com",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11897",
              "STATE": "PUBLIC",
              "TITLE": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "IoT Gateway Software",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "9.3.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bosch"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "mBS SDK",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "8.2.6"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ProSyst"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.6"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-918 Server-Side Request Forgery (SSRF)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2019-11897",
        "datePublished": "2019-08-21T17:09:52.545Z",
        "dateReserved": "2019-05-13T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:55:02.429Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11603 (GCVE-0-2019-11603)

    Vulnerability from cvelistv5 – Published: 2019-08-21 19:29 – Updated: 2024-09-16 23:46
    VLAI
    Title
    Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:55:41.027Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T19:29:23.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11603",
              "STATE": "PUBLIC",
              "TITLE": "Path traversal in ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-11603",
        "datePublished": "2019-08-21T19:29:23.032Z",
        "dateReserved": "2019-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:46:18.811Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11602 (GCVE-0-2019-11602)

    Vulnerability from cvelistv5 – Published: 2019-08-21 19:21 – Updated: 2024-09-17 00:56
    VLAI
    Title
    Leakage of stack traces in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    Leakage of stack traces in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:55:41.050Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T19:21:38.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11602",
              "STATE": "PUBLIC",
              "TITLE": "Leakage of stack traces in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Leakage of stack traces in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-11602",
        "datePublished": "2019-08-21T19:21:38.452Z",
        "dateReserved": "2019-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:56:40.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11601 (GCVE-0-2019-11601)

    Vulnerability from cvelistv5 – Published: 2019-08-21 19:09 – Updated: 2024-09-16 17:59
    VLAI
    Title
    Path traversal in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    A directory traversal vulnerability in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:55:41.059Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T19:09:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11601",
              "STATE": "PUBLIC",
              "TITLE": "Path traversal in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A directory traversal vulnerability in remote access to backup \u0026 restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to write or delete files at any location."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-11601",
        "datePublished": "2019-08-21T19:09:01.029Z",
        "dateReserved": "2019-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:59:22.845Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11897 (GCVE-0-2019-11897)

    Vulnerability from cvelistv5 – Published: 2019-08-21 17:09 – Updated: 2024-09-17 03:55
    VLAI
    Title
    Server-side request forgery in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
    Summary
    A Server-Side Request Forgery (SSRF) vulnerability in the backup & restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server.
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bosch IoT Gateway Software Affected: unspecified , < 9.3.0 (custom)
    Create a notification for this product.
    ProSyst mBS SDK Affected: unspecified , < 8.2.6 (custom)
    Create a notification for this product.
    Date Public
    2019-08-19 00:00
    Credits
    Philip Kazmeier
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:10:29.663Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "IoT Gateway Software",
              "vendor": "Bosch",
              "versions": [
                {
                  "lessThan": "9.3.0",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mBS SDK",
              "vendor": "ProSyst",
              "versions": [
                {
                  "lessThan": "8.2.6",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Philip Kazmeier"
            }
          ],
          "datePublic": "2019-08-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "CWE-918 Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-21T17:09:52.000Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
            }
          ],
          "source": {
            "advisory": "BOSCH-SA-562575",
            "discovery": "EXTERNAL"
          },
          "title": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
          "x_generator": {
            "engine": "Vulnogram 0.0.6"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@bosch.com",
              "DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
              "ID": "CVE-2019-11897",
              "STATE": "PUBLIC",
              "TITLE": "Server-side request forgery in the backup \u0026 restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "IoT Gateway Software",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "9.3.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bosch"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "mBS SDK",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "8.2.6"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ProSyst"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Philip Kazmeier"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup \u0026 restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.6"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-918 Server-Side Request Forgery (SSRF)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
                }
              ]
            },
            "source": {
              "advisory": "BOSCH-SA-562575",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2019-11897",
        "datePublished": "2019-08-21T17:09:52.545Z",
        "dateReserved": "2019-05-13T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:55:02.429Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }