Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for prodesk_400_g5_small_form_factor_firmware by hp

    CVE-2022-31646 (GCVE-0-2022-31646)

    Vulnerability from nvd – Published: 2023-06-14 17:07 – Updated: 2024-12-30 15:01
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:00.896Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-31646",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:01:37.405808Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-863",
                    "description": "CWE-863 Incorrect Authorization",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:01:46.211Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T17:07:52.139Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-31646",
        "datePublished": "2023-06-14T17:07:52.139Z",
        "dateReserved": "2022-05-25T21:05:10.868Z",
        "dateUpdated": "2024-12-30T15:01:46.211Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-31645 (GCVE-0-2022-31645)

    Vulnerability from nvd – Published: 2023-06-14 17:07 – Updated: 2024-12-30 15:09
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:00.999Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-31645",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:09:15.609954Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-362",
                    "description": "CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:09:21.775Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure. "
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T17:07:00.373Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-31645",
        "datePublished": "2023-06-14T17:07:00.373Z",
        "dateReserved": "2022-05-25T21:05:10.868Z",
        "dateUpdated": "2024-12-30T15:09:21.775Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-31644 (GCVE-0-2022-31644)

    Vulnerability from nvd – Published: 2023-06-14 17:06 – Updated: 2024-12-30 15:13
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:00.855Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-31644",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:13:52.895157Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-863",
                    "description": "CWE-863 Incorrect Authorization",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:13:57.891Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T17:06:30.332Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-31644",
        "datePublished": "2023-06-14T17:06:30.332Z",
        "dateReserved": "2022-05-25T21:05:10.868Z",
        "dateUpdated": "2024-12-30T15:13:57.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27537 (GCVE-0-2022-27537)

    Vulnerability from nvd – Published: 2023-01-30 21:26 – Updated: 2025-03-27 15:23
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate these potential vulnerabilities.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.263Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-27537",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:21:15.511462Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-94",
                    "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:23:56.436Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate these potential vulnerabilities."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-01T06:15:59.102Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-27537",
        "datePublished": "2023-01-30T21:26:11.879Z",
        "dateReserved": "2022-03-21T21:15:05.750Z",
        "dateUpdated": "2025-03-27T15:23:56.436Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-31646 (GCVE-0-2022-31646)

    Vulnerability from cvelistv5 – Published: 2023-06-14 17:07 – Updated: 2024-12-30 15:01
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:00.896Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-31646",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:01:37.405808Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-863",
                    "description": "CWE-863 Incorrect Authorization",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:01:46.211Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T17:07:52.139Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-31646",
        "datePublished": "2023-06-14T17:07:52.139Z",
        "dateReserved": "2022-05-25T21:05:10.868Z",
        "dateUpdated": "2024-12-30T15:01:46.211Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-31645 (GCVE-0-2022-31645)

    Vulnerability from cvelistv5 – Published: 2023-06-14 17:07 – Updated: 2024-12-30 15:09
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:00.999Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-31645",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:09:15.609954Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-362",
                    "description": "CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:09:21.775Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure. "
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T17:07:00.373Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-31645",
        "datePublished": "2023-06-14T17:07:00.373Z",
        "dateReserved": "2022-05-25T21:05:10.868Z",
        "dateUpdated": "2024-12-30T15:09:21.775Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-31644 (GCVE-0-2022-31644)

    Vulnerability from cvelistv5 – Published: 2023-06-14 17:06 – Updated: 2024-12-30 15:13
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:00.855Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-31644",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-30T15:13:52.895157Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-863",
                    "description": "CWE-863 Incorrect Authorization",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-30T15:13:57.891Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T17:06:30.332Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-31644",
        "datePublished": "2023-06-14T17:06:30.332Z",
        "dateReserved": "2022-05-25T21:05:10.868Z",
        "dateUpdated": "2024-12-30T15:13:57.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27537 (GCVE-0-2022-27537)

    Vulnerability from cvelistv5 – Published: 2023-01-30 21:26 – Updated: 2025-03-27 15:23
    VLAI
    Summary
    Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate these potential vulnerabilities.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP PC BIOS Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.263Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-27537",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:21:15.511462Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-94",
                    "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:23:56.436Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP PC BIOS",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Potential vulnerabilities have been identified in the system BIOS of certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate these potential vulnerabilities."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-01T06:15:59.102Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_6664419-6664458-16/hpsbhf03806"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.13"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2022-27537",
        "datePublished": "2023-01-30T21:26:11.879Z",
        "dateReserved": "2022-03-21T21:15:05.750Z",
        "dateUpdated": "2025-03-27T15:23:56.436Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }