Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for print_and_scan_doctor by hp

    CVE-2023-5671 (GCVE-0-2023-5671)

    Vulnerability from nvd – Published: 2023-10-25 17:11 – Updated: 2024-09-12 14:19
    VLAI
    Summary
    HP Print and Scan Doctor for Windows may potentially be vulnerable to escalation of privilege. HP is releasing software updates to mitigate the potential vulnerability.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP Print and Scan Doctor for Windows Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:07:32.336Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_9502679-9502704-16"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5671",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-10T13:19:16.312280Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T14:19:17.392Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "HP Print and Scan Doctor for Windows",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "HP Print and Scan Doctor for Windows may potentially be vulnerable to escalation of privilege. HP is releasing software updates to mitigate the potential vulnerability."
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-25T17:11:05.225Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_9502679-9502704-16"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.15"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2023-5671",
        "datePublished": "2023-10-25T17:11:05.225Z",
        "dateReserved": "2023-10-19T21:00:03.116Z",
        "dateUpdated": "2024-09-12T14:19:17.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6931 (GCVE-0-2020-6931)

    Vulnerability from nvd – Published: 2021-11-03 19:07 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    HP Print and Scan Doctor may potentially be vulnerable to local elevation of privilege.
    Severity
    No CVSS data available.
    CWE
    • Local Elevation of Privilege
    Assigner
    hp
    References
    Impacted products
    Vendor Product Version
    n/a HP Print and Scan Doctor Affected: before 5.51
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:01.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/c06982375"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP Print and Scan Doctor",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before 5.51"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "HP Print and Scan Doctor may potentially be vulnerable to local elevation of privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Local Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-03T19:07:43.000Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.hp.com/us-en/document/c06982375"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "hp-security-alert@hp.com",
              "ID": "CVE-2020-6931",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "HP Print and Scan Doctor",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "before 5.51"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "HP Print and Scan Doctor may potentially be vulnerable to local elevation of privilege."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Local Elevation of Privilege"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.hp.com/us-en/document/c06982375",
                  "refsource": "MISC",
                  "url": "https://support.hp.com/us-en/document/c06982375"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2020-6931",
        "datePublished": "2021-11-03T19:07:43.000Z",
        "dateReserved": "2020-01-13T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:01.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5671 (GCVE-0-2023-5671)

    Vulnerability from cvelistv5 – Published: 2023-10-25 17:11 – Updated: 2024-09-12 14:19
    VLAI
    Summary
    HP Print and Scan Doctor for Windows may potentially be vulnerable to escalation of privilege. HP is releasing software updates to mitigate the potential vulnerability.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    hp
    Impacted products
    Vendor Product Version
    HP Inc. HP Print and Scan Doctor for Windows Affected: See HP Security Bulletin reference for affected versions.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:07:32.336Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/ish_9502679-9502704-16"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5671",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-10T13:19:16.312280Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T14:19:17.392Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "HP Print and Scan Doctor for Windows",
              "vendor": "HP Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "See HP Security Bulletin reference for affected versions."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "HP Print and Scan Doctor for Windows may potentially be vulnerable to escalation of privilege. HP is releasing software updates to mitigate the potential vulnerability."
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-25T17:11:05.225Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "url": "https://support.hp.com/us-en/document/ish_9502679-9502704-16"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.15"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2023-5671",
        "datePublished": "2023-10-25T17:11:05.225Z",
        "dateReserved": "2023-10-19T21:00:03.116Z",
        "dateUpdated": "2024-09-12T14:19:17.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6931 (GCVE-0-2020-6931)

    Vulnerability from cvelistv5 – Published: 2021-11-03 19:07 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    HP Print and Scan Doctor may potentially be vulnerable to local elevation of privilege.
    Severity
    No CVSS data available.
    CWE
    • Local Elevation of Privilege
    Assigner
    hp
    References
    Impacted products
    Vendor Product Version
    n/a HP Print and Scan Doctor Affected: before 5.51
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:01.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.hp.com/us-en/document/c06982375"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HP Print and Scan Doctor",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before 5.51"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "HP Print and Scan Doctor may potentially be vulnerable to local elevation of privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Local Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-03T19:07:43.000Z",
            "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
            "shortName": "hp"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.hp.com/us-en/document/c06982375"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "hp-security-alert@hp.com",
              "ID": "CVE-2020-6931",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "HP Print and Scan Doctor",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "before 5.51"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "HP Print and Scan Doctor may potentially be vulnerable to local elevation of privilege."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Local Elevation of Privilege"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.hp.com/us-en/document/c06982375",
                  "refsource": "MISC",
                  "url": "https://support.hp.com/us-en/document/c06982375"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "assignerShortName": "hp",
        "cveId": "CVE-2020-6931",
        "datePublished": "2021-11-03T19:07:43.000Z",
        "dateReserved": "2020-01-13T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:01.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }