    CVE-2020-5326 (GCVE-0-2020-5326)

    Vulnerability from nvd – Published: 2020-02-21 14:50 – Updated: 2024-09-17 01:56
    VLAI
    Summary
    Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Client Consumer and Commercial Platforms Affected: https://www.dell.com/support/article/SLN320337
    Create a notification for this product.
    Date Public
    2020-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:22:09.254Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/article/SLN320337"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Dell Client Consumer and Commercial Platforms",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "https://www.dell.com/support/article/SLN320337"
                }
              ]
            }
          ],
          "datePublic": "2020-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-21T14:50:14.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/article/SLN320337"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2020-02-18",
              "ID": "CVE-2020-5326",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Dell Client Consumer and Commercial Platforms",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "https://www.dell.com/support/article/SLN320337"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 6.1,
                "baseSeverity": "Medium",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/article/SLN320337",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/article/SLN320337"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2020-5326",
        "datePublished": "2020-02-21T14:50:14.182Z",
        "dateReserved": "2020-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:56:45.382Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5326 (GCVE-0-2020-5326)

    Vulnerability from cvelistv5 – Published: 2020-02-21 14:50 – Updated: 2024-09-17 01:56
    VLAI
    Summary
    Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Client Consumer and Commercial Platforms Affected: https://www.dell.com/support/article/SLN320337
    Create a notification for this product.
    Date Public
    2020-02-18 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:22:09.254Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/article/SLN320337"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Dell Client Consumer and Commercial Platforms",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "https://www.dell.com/support/article/SLN320337"
                }
              ]
            }
          ],
          "datePublic": "2020-02-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-21T14:50:14.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/article/SLN320337"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2020-02-18",
              "ID": "CVE-2020-5326",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Dell Client Consumer and Commercial Platforms",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "https://www.dell.com/support/article/SLN320337"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 6.1,
                "baseSeverity": "Medium",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/article/SLN320337",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/article/SLN320337"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2020-5326",
        "datePublished": "2020-02-21T14:50:14.182Z",
        "dateReserved": "2020-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:56:45.382Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }