Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for prc2402m_firmware by prolink

    CVE-2021-36708 (GCVE-0-2021-36708)

    Vulnerability from nvd – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:59.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:36.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36708",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36708",
        "datePublished": "2021-08-06T13:19:36.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:59.415Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36707 (GCVE-0-2021-36707)

    Vulnerability from nvd – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:59.348Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:30.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36707",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36707",
        "datePublished": "2021-08-06T13:19:30.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:59.348Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36706 (GCVE-0-2021-36706)

    Vulnerability from nvd – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:58.962Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:24.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36706",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36706",
        "datePublished": "2021-08-06T13:19:24.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:58.962Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36705 (GCVE-0-2021-36705)

    Vulnerability from nvd – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:58.968Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:17.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36705",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36705",
        "datePublished": "2021-08-06T13:19:17.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:58.968Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36708 (GCVE-0-2021-36708)

    Vulnerability from cvelistv5 – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:59.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:36.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36708",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36708",
        "datePublished": "2021-08-06T13:19:36.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:59.415Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36707 (GCVE-0-2021-36707)

    Vulnerability from cvelistv5 – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:59.348Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:30.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36707",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36707",
        "datePublished": "2021-08-06T13:19:30.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:59.348Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36706 (GCVE-0-2021-36706)

    Vulnerability from cvelistv5 – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:58.962Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:24.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36706",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36706",
        "datePublished": "2021-08-06T13:19:24.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:58.962Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-36705 (GCVE-0-2021-36705)

    Vulnerability from cvelistv5 – Published: 2021-08-06 13:19 – Updated: 2024-08-04 01:01
    VLAI
    Summary
    In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:01:58.968Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-06T13:19:17.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-36705",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection",
                  "refsource": "MISC",
                  "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-36705",
        "datePublished": "2021-08-06T13:19:17.000Z",
        "dateReserved": "2021-07-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:01:58.968Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }