CVE-2025-43938 (GCVE-0-2025-43938)

Vulnerability from nvd – Published: 2025-09-10 16:03 – Updated: 2025-09-10 18:04
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account.
CWE
  • CWE-256 - Plaintext Storage of a Password
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43938",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-10T18:04:05.557915Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-10T18:04:13.097Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-256",
              "description": "CWE-256: Plaintext Storage of a Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T16:03:38.951Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43938",
    "datePublished": "2025-09-10T16:03:38.951Z",
    "dateReserved": "2025-04-20T05:04:01.415Z",
    "dateUpdated": "2025-09-10T18:04:13.097Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43888 (GCVE-0-2025-43888)

Vulnerability from nvd – Published: 2025-09-10 15:42 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43888",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:26.040843Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:20.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
            }
          ],
          "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:43:08.746Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43888",
    "datePublished": "2025-09-10T15:42:34.448Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T14:43:20.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43887 (GCVE-0-2025-43887)

Vulnerability from nvd – Published: 2025-09-10 15:59 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43887",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:28.607021Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:04.073Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276: Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:59:56.185Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43887",
    "datePublished": "2025-09-10T15:59:56.185Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T14:43:04.073Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43886 (GCVE-0-2025-43886)

Vulnerability from nvd – Published: 2025-09-10 16:08 – Updated: 2025-09-11 13:24
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: '.../...//' vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
CWE
  • CWE-35 - Path Traversal: '.../...//'
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T13:24:22.142728Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T13:24:30.089Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-35",
              "description": "CWE-35: Path Traversal: \u0027.../...//\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T16:08:55.075Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43886",
    "datePublished": "2025-09-10T16:08:55.075Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T13:24:30.089Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43885 (GCVE-0-2025-43885)

Vulnerability from nvd – Published: 2025-09-10 15:52 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43885",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:24.294455Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:15.488Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:52:28.608Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43885",
    "datePublished": "2025-09-10T15:52:28.608Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T14:43:15.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43884 (GCVE-0-2025-43884)

Vulnerability from nvd – Published: 2025-09-10 15:47 – Updated: 2025-09-11 03:56
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43884",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-10T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T03:56:24.631Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:47:40.671Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43884",
    "datePublished": "2025-09-10T15:47:40.671Z",
    "dateReserved": "2025-04-18T05:05:05.740Z",
    "dateUpdated": "2025-09-11T03:56:24.631Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43725 (GCVE-0-2025-43725)

Vulnerability from nvd – Published: 2025-09-10 15:56 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43725",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:29.492613Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:09.450Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
            }
          ],
          "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276: Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:56:08.961Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43725",
    "datePublished": "2025-09-10T15:56:08.961Z",
    "dateReserved": "2025-04-17T05:03:55.667Z",
    "dateUpdated": "2025-09-11T14:43:09.450Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30480 (GCVE-0-2025-30480)

Vulnerability from nvd – Published: 2025-07-30 18:01 – Updated: 2025-07-30 18:21
VLAI?
Summary
Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.20 (semver)
Create a notification for this product.
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30480",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-30T18:20:42.511595Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-30T18:21:24.665Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.20",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
        }
      ],
      "datePublic": "2025-07-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.\u003c/span\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-30T18:01:53.920Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000349609/dsa-2025-304-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-30480",
    "datePublished": "2025-07-30T18:01:53.920Z",
    "dateReserved": "2025-03-23T18:45:23.729Z",
    "dateUpdated": "2025-07-30T18:21:24.665Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23377 (GCVE-0-2025-23377)

Vulnerability from nvd – Published: 2025-04-28 14:38 – Updated: 2025-04-28 14:50
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.
CWE
  • CWE-116 - Improper Encoding or Escaping of Output
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23377",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-28T14:50:02.276406Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-28T14:50:15.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-116",
              "description": "CWE-116: Improper Encoding or Escaping of Output",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:38:01.852Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23377",
    "datePublished": "2025-04-28T14:38:01.852Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-28T14:50:15.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23376 (GCVE-0-2025-23376)

Vulnerability from nvd – Published: 2025-04-28 14:34 – Updated: 2025-04-28 17:31
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.
CWE
  • CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Reporting Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23376",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-28T17:30:57.741219Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-28T17:31:27.959Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager Reporting",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1336",
              "description": "CWE-1336: Improper Neutralization of Special Elements Used in a Template Engine",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:34:13.504Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23376",
    "datePublished": "2025-04-28T14:34:13.504Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-28T17:31:27.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23375 (GCVE-0-2025-23375)

Vulnerability from nvd – Published: 2025-04-28 14:28 – Updated: 2025-04-30 03:56
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
CWE
  • CWE-648 - Incorrect Use of Privileged APIs
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23375",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-30T03:56:25.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-648",
              "description": "CWE-648: Incorrect Use of Privileged APIs",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:28:03.669Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23375",
    "datePublished": "2025-04-28T14:28:03.669Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-30T03:56:25.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25971 (GCVE-0-2024-25971)

Vulnerability from nvd – Published: 2024-03-28 18:43 – Updated: 2024-08-01 23:52
VLAI?
Summary
Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service.
CWE
  • CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.16 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-25971",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-28T19:31:40.256120Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:21:20.844Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:06.184Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.16",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-03-28T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611: Improper Restriction of XML External Entity Reference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-28T18:43:06.075Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-25971",
    "datePublished": "2024-03-28T18:43:06.075Z",
    "dateReserved": "2024-02-13T05:34:25.249Z",
    "dateUpdated": "2024-08-01T23:52:06.184Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-22454 (GCVE-0-2024-22454)

Vulnerability from nvd – Published: 2024-02-13 07:35 – Updated: 2025-05-09 18:26
VLAI?
Summary
Dell PowerProtect Data Manager, version 19.15 and prior versions, contain a weak password recovery mechanism for forgotten passwords. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to the application with privileges of the compromised account. The attacker could retrieve the reset password token without authorization and then perform the password change
CWE
  • CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 0 , ≤ 19.15 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.983Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22454",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T18:44:51.708724Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-09T18:26:40.775Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-02-13T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, version 19.15 and prior versions, contain a weak password recovery mechanism for forgotten passwords. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to the application with privileges of the compromised account. The attacker could retrieve the reset password token without authorization and then perform the password change\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell PowerProtect Data Manager, version 19.15 and prior versions, contain a weak password recovery mechanism for forgotten passwords. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to the application with privileges of the compromised account. The attacker could retrieve the reset password token without authorization and then perform the password change\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-640",
              "description": "CWE-640: Weak Password Recovery Mechanism for Forgotten Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-13T07:43:15.451Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-22454",
    "datePublished": "2024-02-13T07:35:35.667Z",
    "dateReserved": "2024-01-10T15:26:10.251Z",
    "dateUpdated": "2025-05-09T18:26:40.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-22445 (GCVE-0-2024-22445)

Vulnerability from nvd – Published: 2024-02-13 07:40 – Updated: 2024-08-22 15:28
VLAI?
Summary
Dell PowerProtect Data Manager, version 19.15 and prior versions, contain an OS command injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 0 , ≤ 19.15 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.937Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:dell:powerprotect_data_manager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "powerprotect_data_manager",
            "vendor": "dell",
            "versions": [
              {
                "lessThanOrEqual": "19.15",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22445",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-22T15:17:36.441308Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-22T15:28:00.442Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-02-13T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, version 19.15 and prior versions, contain an OS command injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell PowerProtect Data Manager, version 19.15 and prior versions, contain an OS command injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-13T07:42:23.027Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-22445",
    "datePublished": "2024-02-13T07:40:20.900Z",
    "dateReserved": "2024-01-10T15:26:10.250Z",
    "dateUpdated": "2024-08-22T15:28:00.442Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28062 (GCVE-0-2023-28062)

Vulnerability from nvd – Published: 2023-04-11 13:55 – Updated: 2025-02-07 16:30
VLAI?
Summary
Dell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.
CWE
  • CWE-648 - Incorrect Use of Privileged APIs
Assigner
References
Impacted products
Vendor Product Version
Dell PPDM Reporting (PowerProtect Data Manager) Affected: 19.10, 19.11 and 19.12
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:30:23.628Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28062",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-07T16:30:28.845773Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-07T16:30:36.177Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PPDM Reporting (PowerProtect Data Manager)",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "19.10, 19.11 and 19.12"
            }
          ]
        }
      ],
      "datePublic": "2023-04-11T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-648",
              "description": "CWE-648: Incorrect Use of Privileged APIs",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T13:55:40.618Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-28062",
    "datePublished": "2023-04-11T13:55:40.618Z",
    "dateReserved": "2023-03-10T05:06:06.441Z",
    "dateUpdated": "2025-02-07T16:30:36.177Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43886 (GCVE-0-2025-43886)

Vulnerability from cvelistv5 – Published: 2025-09-10 16:08 – Updated: 2025-09-11 13:24
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: '.../...//' vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
CWE
  • CWE-35 - Path Traversal: '.../...//'
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T13:24:22.142728Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T13:24:30.089Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-35",
              "description": "CWE-35: Path Traversal: \u0027.../...//\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T16:08:55.075Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43886",
    "datePublished": "2025-09-10T16:08:55.075Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T13:24:30.089Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43938 (GCVE-0-2025-43938)

Vulnerability from cvelistv5 – Published: 2025-09-10 16:03 – Updated: 2025-09-10 18:04
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account.
CWE
  • CWE-256 - Plaintext Storage of a Password
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43938",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-10T18:04:05.557915Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-10T18:04:13.097Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-256",
              "description": "CWE-256: Plaintext Storage of a Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T16:03:38.951Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43938",
    "datePublished": "2025-09-10T16:03:38.951Z",
    "dateReserved": "2025-04-20T05:04:01.415Z",
    "dateUpdated": "2025-09-10T18:04:13.097Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43887 (GCVE-0-2025-43887)

Vulnerability from cvelistv5 – Published: 2025-09-10 15:59 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43887",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:28.607021Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:04.073Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276: Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:59:56.185Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43887",
    "datePublished": "2025-09-10T15:59:56.185Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T14:43:04.073Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43725 (GCVE-0-2025-43725)

Vulnerability from cvelistv5 – Published: 2025-09-10 15:56 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43725",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:29.492613Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:09.450Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
            }
          ],
          "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276: Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:56:08.961Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43725",
    "datePublished": "2025-09-10T15:56:08.961Z",
    "dateReserved": "2025-04-17T05:03:55.667Z",
    "dateUpdated": "2025-09-11T14:43:09.450Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43885 (GCVE-0-2025-43885)

Vulnerability from cvelistv5 – Published: 2025-09-10 15:52 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43885",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:24.294455Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:15.488Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:52:28.608Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43885",
    "datePublished": "2025-09-10T15:52:28.608Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T14:43:15.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43884 (GCVE-0-2025-43884)

Vulnerability from cvelistv5 – Published: 2025-09-10 15:47 – Updated: 2025-09-11 03:56
VLAI?
Summary
Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43884",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-10T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T03:56:24.631Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:47:40.671Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43884",
    "datePublished": "2025-09-10T15:47:40.671Z",
    "dateReserved": "2025-04-18T05:05:05.740Z",
    "dateUpdated": "2025-09-11T03:56:24.631Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43888 (GCVE-0-2025-43888)

Vulnerability from cvelistv5 – Published: 2025-09-10 15:42 – Updated: 2025-09-11 14:43
VLAI?
Summary
Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43888",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-11T03:56:26.040843Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-11T14:43:20.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.21 build 11",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
            }
          ],
          "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-10T15:43:08.746Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43888",
    "datePublished": "2025-09-10T15:42:34.448Z",
    "dateReserved": "2025-04-18T05:05:05.741Z",
    "dateUpdated": "2025-09-11T14:43:20.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30480 (GCVE-0-2025-30480)

Vulnerability from cvelistv5 – Published: 2025-07-30 18:01 – Updated: 2025-07-30 18:21
VLAI?
Summary
Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.20 (semver)
Create a notification for this product.
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30480",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-30T18:20:42.511595Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-30T18:21:24.665Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.20",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
        }
      ],
      "datePublic": "2025-07-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.\u003c/span\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-30T18:01:53.920Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000349609/dsa-2025-304-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-30480",
    "datePublished": "2025-07-30T18:01:53.920Z",
    "dateReserved": "2025-03-23T18:45:23.729Z",
    "dateUpdated": "2025-07-30T18:21:24.665Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23377 (GCVE-0-2025-23377)

Vulnerability from cvelistv5 – Published: 2025-04-28 14:38 – Updated: 2025-04-28 14:50
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.
CWE
  • CWE-116 - Improper Encoding or Escaping of Output
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23377",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-28T14:50:02.276406Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-28T14:50:15.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-116",
              "description": "CWE-116: Improper Encoding or Escaping of Output",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:38:01.852Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23377",
    "datePublished": "2025-04-28T14:38:01.852Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-28T14:50:15.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23376 (GCVE-0-2025-23376)

Vulnerability from cvelistv5 – Published: 2025-04-28 14:34 – Updated: 2025-04-28 17:31
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.
CWE
  • CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Reporting Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23376",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-28T17:30:57.741219Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-28T17:31:27.959Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager Reporting",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1336",
              "description": "CWE-1336: Improper Neutralization of Special Elements Used in a Template Engine",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:34:13.504Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23376",
    "datePublished": "2025-04-28T14:34:13.504Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-28T17:31:27.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23375 (GCVE-0-2025-23375)

Vulnerability from cvelistv5 – Published: 2025-04-28 14:28 – Updated: 2025-04-30 03:56
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
CWE
  • CWE-648 - Incorrect Use of Privileged APIs
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23375",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-30T03:56:25.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-648",
              "description": "CWE-648: Incorrect Use of Privileged APIs",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:28:03.669Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23375",
    "datePublished": "2025-04-28T14:28:03.669Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-30T03:56:25.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25971 (GCVE-0-2024-25971)

Vulnerability from cvelistv5 – Published: 2024-03-28 18:43 – Updated: 2024-08-01 23:52
VLAI?
Summary
Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service.
CWE
  • CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: N/A , < 19.16 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-25971",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-28T19:31:40.256120Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:21:20.844Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:06.184Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "19.16",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-03-28T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
            }
          ],
          "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611: Improper Restriction of XML External Entity Reference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-28T18:43:06.075Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-25971",
    "datePublished": "2024-03-28T18:43:06.075Z",
    "dateReserved": "2024-02-13T05:34:25.249Z",
    "dateUpdated": "2024-08-01T23:52:06.184Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-22445 (GCVE-0-2024-22445)

Vulnerability from cvelistv5 – Published: 2024-02-13 07:40 – Updated: 2024-08-22 15:28
VLAI?
Summary
Dell PowerProtect Data Manager, version 19.15 and prior versions, contain an OS command injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 0 , ≤ 19.15 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.937Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:dell:powerprotect_data_manager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "powerprotect_data_manager",
            "vendor": "dell",
            "versions": [
              {
                "lessThanOrEqual": "19.15",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22445",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-22T15:17:36.441308Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-22T15:28:00.442Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-02-13T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, version 19.15 and prior versions, contain an OS command injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell PowerProtect Data Manager, version 19.15 and prior versions, contain an OS command injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-13T07:42:23.027Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-22445",
    "datePublished": "2024-02-13T07:40:20.900Z",
    "dateReserved": "2024-01-10T15:26:10.250Z",
    "dateUpdated": "2024-08-22T15:28:00.442Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-22454 (GCVE-0-2024-22454)

Vulnerability from cvelistv5 – Published: 2024-02-13 07:35 – Updated: 2025-05-09 18:26
VLAI?
Summary
Dell PowerProtect Data Manager, version 19.15 and prior versions, contain a weak password recovery mechanism for forgotten passwords. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to the application with privileges of the compromised account. The attacker could retrieve the reset password token without authorization and then perform the password change
CWE
  • CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Affected: 0 , ≤ 19.15 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.983Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22454",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T18:44:51.708724Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-09T18:26:40.775Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-02-13T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, version 19.15 and prior versions, contain a weak password recovery mechanism for forgotten passwords. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to the application with privileges of the compromised account. The attacker could retrieve the reset password token without authorization and then perform the password change\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell PowerProtect Data Manager, version 19.15 and prior versions, contain a weak password recovery mechanism for forgotten passwords. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to the application with privileges of the compromised account. The attacker could retrieve the reset password token without authorization and then perform the password change\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-640",
              "description": "CWE-640: Weak Password Recovery Mechanism for Forgotten Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-13T07:43:15.451Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-22454",
    "datePublished": "2024-02-13T07:35:35.667Z",
    "dateReserved": "2024-01-10T15:26:10.251Z",
    "dateUpdated": "2025-05-09T18:26:40.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28062 (GCVE-0-2023-28062)

Vulnerability from cvelistv5 – Published: 2023-04-11 13:55 – Updated: 2025-02-07 16:30
VLAI?
Summary
Dell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.
CWE
  • CWE-648 - Incorrect Use of Privileged APIs
Assigner
References
Impacted products
Vendor Product Version
Dell PPDM Reporting (PowerProtect Data Manager) Affected: 19.10, 19.11 and 19.12
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:30:23.628Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28062",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-07T16:30:28.845773Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-07T16:30:36.177Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PPDM Reporting (PowerProtect Data Manager)",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "19.10, 19.11 and 19.12"
            }
          ]
        }
      ],
      "datePublic": "2023-04-11T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-648",
              "description": "CWE-648: Incorrect Use of Privileged APIs",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T13:55:40.618Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-28062",
    "datePublished": "2023-04-11T13:55:40.618Z",
    "dateReserved": "2023-03-10T05:06:06.441Z",
    "dateUpdated": "2025-02-07T16:30:36.177Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",