Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
12 vulnerabilities found for poweredge_c4130_firmware by dell
CVE-2024-25942 (GCVE-0-2024-25942)
Vulnerability from nvd – Published: 2024-03-19 07:52 – Updated: 2024-08-12 13:53
VLAI?
Summary
Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
4.4 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Date Public ?
2024-03-18 06:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:53:19.426811Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:53:37.973Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:52:29.228Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25942",
"datePublished": "2024-03-19T07:52:29.228Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2024-08-12T13:53:37.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22453 (GCVE-0-2024-22453)
Vulnerability from nvd – Published: 2024-03-19 07:42 – Updated: 2024-08-01 22:43
VLAI?
Summary
Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory.
Severity ?
7.2 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Date Public ?
2024-03-18 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22453",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-19T14:44:45.916921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:52.907Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.929Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue"
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:42:27.785Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-22453",
"datePublished": "2024-03-19T07:42:27.785Z",
"dateReserved": "2024-01-10T15:26:10.251Z",
"dateUpdated": "2024-08-01T22:43:34.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0173 (GCVE-0-2024-0173)
Vulnerability from nvd – Published: 2024-03-13 16:52 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Date Public ?
2024-03-12 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0173",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T20:00:50.556667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:23.919Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.066Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform\t",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:52:21.293Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0173",
"datePublished": "2024-03-13T16:52:21.293Z",
"dateReserved": "2023-12-14T05:35:37.836Z",
"dateUpdated": "2024-08-01T17:41:16.066Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0154 (GCVE-0-2024-0154)
Vulnerability from nvd – Published: 2024-03-13 16:41 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Date Public ?
2024-03-12 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T19:40:48.987776Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:45.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:41:09.360Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0154",
"datePublished": "2024-03-13T16:41:09.360Z",
"dateReserved": "2023-12-14T05:29:25.760Z",
"dateUpdated": "2024-08-01T17:41:16.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0161 (GCVE-0-2024-0161)
Vulnerability from nvd – Published: 2024-03-13 16:04 – Updated: 2024-08-12 13:56
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
7.2 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 1.1.1
(semver)
Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Date Public ?
2024-03-12 06:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:15.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:56:13.395413Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:56:29.418Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.1.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:04:12.678Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0161",
"datePublished": "2024-03-13T16:04:12.678Z",
"dateReserved": "2023-12-14T05:30:39.766Z",
"dateUpdated": "2024-08-12T13:56:29.418Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32460 (GCVE-0-2023-32460)
Vulnerability from nvd – Published: 2023-12-08 05:37 – Updated: 2024-08-02 15:18
VLAI?
Summary
Dell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
Versions prior to 1.6.6
Affected: Versions prior to 1.3.6 Affected: Versions prior to 1.1.2 Affected: Versions prior to 1.12.1 Affected: Versions prior to 1.8.1 Affected: Versions prior to 1.13.3 Affected: Versions prior to 2.13.3 Affected: Versions prior to 2.20.1 Affected: Versions prior to 2.20.0 Affected: Versions prior to 2.15.1 Affected: Versions prior to 1.21.0 Affected: Versions prior to 2.18.1 Affected: Versions prior to 2.13.0 Affected: Versions prior to 2.18.2 Affected: Versions prior to 1.18.1 Affected: Versions prior to 2.19.1 |
Date Public ?
2023-12-07 06:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:18:37.251Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"BIOS"
],
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 1.6.6"
},
{
"status": "affected",
"version": "Versions prior to 1.3.6"
},
{
"status": "affected",
"version": "Versions prior to 1.1.2"
},
{
"status": "affected",
"version": "Versions prior to 1.12.1"
},
{
"status": "affected",
"version": "Versions prior to 1.8.1"
},
{
"status": "affected",
"version": "Versions prior to 1.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.20.1"
},
{
"status": "affected",
"version": "Versions prior to 2.20.0"
},
{
"status": "affected",
"version": "Versions prior to 2.15.1"
},
{
"status": "affected",
"version": "Versions prior to 1.21.0"
},
{
"status": "affected",
"version": "Versions prior to 2.18.1 "
},
{
"status": "affected",
"version": "Versions prior to 2.13.0\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.18.2 "
},
{
"status": "affected",
"version": "Versions prior to 1.18.1\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.19.1\u202f "
}
]
}
],
"datePublic": "2023-12-07T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-08T05:37:52.680Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-32460",
"datePublished": "2023-12-08T05:37:52.680Z",
"dateReserved": "2023-05-09T06:05:24.994Z",
"dateUpdated": "2024-08-02T15:18:37.251Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25942 (GCVE-0-2024-25942)
Vulnerability from cvelistv5 – Published: 2024-03-19 07:52 – Updated: 2024-08-12 13:53
VLAI?
Summary
Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
4.4 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Date Public ?
2024-03-18 06:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:53:19.426811Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:53:37.973Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:52:29.228Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25942",
"datePublished": "2024-03-19T07:52:29.228Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2024-08-12T13:53:37.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22453 (GCVE-0-2024-22453)
Vulnerability from cvelistv5 – Published: 2024-03-19 07:42 – Updated: 2024-08-01 22:43
VLAI?
Summary
Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory.
Severity ?
7.2 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Date Public ?
2024-03-18 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22453",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-19T14:44:45.916921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:52.907Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.929Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue"
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:42:27.785Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-22453",
"datePublished": "2024-03-19T07:42:27.785Z",
"dateReserved": "2024-01-10T15:26:10.251Z",
"dateUpdated": "2024-08-01T22:43:34.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0173 (GCVE-0-2024-0173)
Vulnerability from cvelistv5 – Published: 2024-03-13 16:52 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Date Public ?
2024-03-12 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0173",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T20:00:50.556667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:23.919Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.066Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform\t",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:52:21.293Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0173",
"datePublished": "2024-03-13T16:52:21.293Z",
"dateReserved": "2023-12-14T05:35:37.836Z",
"dateUpdated": "2024-08-01T17:41:16.066Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0154 (GCVE-0-2024-0154)
Vulnerability from cvelistv5 – Published: 2024-03-13 16:41 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Date Public ?
2024-03-12 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T19:40:48.987776Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:45.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:41:09.360Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0154",
"datePublished": "2024-03-13T16:41:09.360Z",
"dateReserved": "2023-12-14T05:29:25.760Z",
"dateUpdated": "2024-08-01T17:41:16.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0161 (GCVE-0-2024-0161)
Vulnerability from cvelistv5 – Published: 2024-03-13 16:04 – Updated: 2024-08-12 13:56
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
7.2 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 1.1.1
(semver)
Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Date Public ?
2024-03-12 06:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:15.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:56:13.395413Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:56:29.418Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.1.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:04:12.678Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0161",
"datePublished": "2024-03-13T16:04:12.678Z",
"dateReserved": "2023-12-14T05:30:39.766Z",
"dateUpdated": "2024-08-12T13:56:29.418Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32460 (GCVE-0-2023-32460)
Vulnerability from cvelistv5 – Published: 2023-12-08 05:37 – Updated: 2024-08-02 15:18
VLAI?
Summary
Dell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
Versions prior to 1.6.6
Affected: Versions prior to 1.3.6 Affected: Versions prior to 1.1.2 Affected: Versions prior to 1.12.1 Affected: Versions prior to 1.8.1 Affected: Versions prior to 1.13.3 Affected: Versions prior to 2.13.3 Affected: Versions prior to 2.20.1 Affected: Versions prior to 2.20.0 Affected: Versions prior to 2.15.1 Affected: Versions prior to 1.21.0 Affected: Versions prior to 2.18.1 Affected: Versions prior to 2.13.0 Affected: Versions prior to 2.18.2 Affected: Versions prior to 1.18.1 Affected: Versions prior to 2.19.1 |
Date Public ?
2023-12-07 06:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:18:37.251Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"BIOS"
],
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 1.6.6"
},
{
"status": "affected",
"version": "Versions prior to 1.3.6"
},
{
"status": "affected",
"version": "Versions prior to 1.1.2"
},
{
"status": "affected",
"version": "Versions prior to 1.12.1"
},
{
"status": "affected",
"version": "Versions prior to 1.8.1"
},
{
"status": "affected",
"version": "Versions prior to 1.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.20.1"
},
{
"status": "affected",
"version": "Versions prior to 2.20.0"
},
{
"status": "affected",
"version": "Versions prior to 2.15.1"
},
{
"status": "affected",
"version": "Versions prior to 1.21.0"
},
{
"status": "affected",
"version": "Versions prior to 2.18.1 "
},
{
"status": "affected",
"version": "Versions prior to 2.13.0\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.18.2 "
},
{
"status": "affected",
"version": "Versions prior to 1.18.1\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.19.1\u202f "
}
]
}
],
"datePublic": "2023-12-07T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-08T05:37:52.680Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-32460",
"datePublished": "2023-12-08T05:37:52.680Z",
"dateReserved": "2023-05-09T06:05:24.994Z",
"dateUpdated": "2024-08-02T15:18:37.251Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}