Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for power_manager by dell

    CVE-2024-49600 (GCVE-0-2024-49600)

    Vulnerability from nvd – Published: 2024-12-09 14:56 – Updated: 2024-12-10 16:47
    VLAI
    Summary
    Dell Power Manager (DPM), versions prior to 3.17, contain an improper access control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of Privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: N/A , < 3.17 (semver)
    Create a notification for this product.
    Date Public
    2024-12-05 06:30
    Credits
    Dell Technologies would like to thank TsungShu Chiu (CHT Security) for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-49600",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-09T22:09:13.049969Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-10T16:47:12.869Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.17",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank TsungShu Chiu (CHT Security) for reporting this issue."
            }
          ],
          "datePublic": "2024-12-05T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Power Manager (DPM), versions prior to 3.17, contain an improper access control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of Privileges."
                }
              ],
              "value": "Dell Power Manager (DPM), versions prior to 3.17, contain an improper access control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of Privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-09T14:56:34.237Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000244438/dsa-2024-439"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-49600",
        "datePublished": "2024-12-09T14:56:34.237Z",
        "dateReserved": "2024-10-17T05:03:48.988Z",
        "dateUpdated": "2024-12-10T16:47:12.869Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39576 (GCVE-0-2024-39576)

    Vulnerability from nvd – Published: 2024-08-22 02:54 – Updated: 2024-08-22 13:39
    VLAI
    Summary
    Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: N/A , < 3.16.0 (semver)
    Create a notification for this product.
    dell power_manager Affected: 0 , < 3.16.0 (semver)
        cpe:2.3:a:dell:power_manager:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-08-21 06:30
    Credits
    Dell would like to thank Lefteris Panos from LRQA Nettitude for reporting this issue
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:dell:power_manager:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "power_manager",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "3.16.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39576",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-22T13:35:22.576186Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-22T13:39:02.079Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.16.0",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank Lefteris Panos from LRQA Nettitude for reporting this issue"
            }
          ],
          "datePublic": "2024-08-21T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges."
                }
              ],
              "value": "Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-22T02:54:05.865Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000227010/dsa-2024-323"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-39576",
        "datePublished": "2024-08-22T02:54:05.865Z",
        "dateReserved": "2024-06-26T02:14:30.866Z",
        "dateUpdated": "2024-08-22T13:39:02.079Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25543 (GCVE-0-2023-25543)

    Vulnerability from nvd – Published: 2024-02-06 06:31 – Updated: 2024-08-02 11:25
    VLAI
    Summary
    Dell Power Manager, versions prior to 3.14, contain an Improper Authorization vulnerability in DPM service. A low privileged malicious user could potentially exploit this vulnerability in order to elevate privileges on the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-280 - Improper Handling of Insufficient Permissions or Privileges
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: 0 , < 3.14 (semver)
    Create a notification for this product.
    Date Public
    2023-04-04 06:30
    Credits
    Cedric Van Bockhaven
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25543",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-02-06T15:42:34.001281Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T17:21:32.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:25:19.264Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000209464/dsa-2023-075"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Cedric Van Bockhaven"
            }
          ],
          "datePublic": "2023-04-04T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Manager, versions prior to 3.14, contain an Improper Authorization vulnerability in DPM service. A low privileged malicious user could potentially exploit this vulnerability in order to elevate privileges on the system. \u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Manager, versions prior to 3.14, contain an Improper Authorization vulnerability in DPM service. A low privileged malicious user could potentially exploit this vulnerability in order to elevate privileges on the system. \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-280",
                  "description": "CWE-280: Improper Handling of Insufficient Permissions or Privileges",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-06T06:31:42.796Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000209464/dsa-2023-075"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-25543",
        "datePublished": "2024-02-06T06:31:20.673Z",
        "dateReserved": "2023-02-07T09:35:27.080Z",
        "dateUpdated": "2024-08-02T11:25:19.264Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32450 (GCVE-0-2023-32450)

    Vulnerability from nvd – Published: 2023-07-27 04:33 – Updated: 2024-10-15 15:39
    VLAI
    Summary
    Dell Power Manager, Versions 3.3 to 3.14 contains an Improper Access Control vulnerability. A low-privileged malicious user may potentially exploit this vulnerability to perform arbitrary code execution with limited access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-379 - Creation of Temporary File in Directory with Insecure Permissions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: Versions 3.3 to 3.14
    Create a notification for this product.
    Date Public
    2023-07-26 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.020Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000215215/dsa-2023-181-dell-power-manager-security-update-for-an-improper-access-control-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T15:12:45.987656Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T15:39:49.985Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 3.3 to 3.14"
                }
              ]
            }
          ],
          "datePublic": "2023-07-26T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Manager, Versions 3.3 to 3.14 contains an Improper Access Control vulnerability. A low-privileged malicious user may potentially exploit this vulnerability to perform arbitrary code execution with limited access.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Manager, Versions 3.3 to 3.14 contains an Improper Access Control vulnerability. A low-privileged malicious user may potentially exploit this vulnerability to perform arbitrary code execution with limited access.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-379",
                  "description": "CWE-379: Creation of Temporary File in Directory with Insecure Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-27T04:33:21.674Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000215215/dsa-2023-181-dell-power-manager-security-update-for-an-improper-access-control-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32450",
        "datePublished": "2023-07-27T04:33:21.674Z",
        "dateReserved": "2023-05-09T06:02:34.291Z",
        "dateUpdated": "2024-10-15T15:39:49.985Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-28051 (GCVE-0-2023-28051)

    Vulnerability from nvd – Published: 2023-04-07 07:20 – Updated: 2025-02-10 16:10
    VLAI
    Summary
    Dell Power Manager, versions 3.10 and prior, contains an Improper Access Control vulnerability. A low-privileged attacker could potentially exploit this vulnerability to elevate privileges on the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: Versions 3.10 and prior
    Create a notification for this product.
    Date Public
    2023-04-06 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:30:24.128Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000211891/dsa-2023-221-dell-power-manager"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-28051",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-10T16:10:05.294743Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-10T16:10:09.477Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 3.10 and prior"
                }
              ]
            }
          ],
          "datePublic": "2023-04-06T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Manager, versions 3.10 and prior, contains an Improper Access Control vulnerability. A low-privileged attacker could potentially exploit this vulnerability to elevate privileges on the system.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Manager, versions 3.10 and prior, contains an Improper Access Control vulnerability. A low-privileged attacker could potentially exploit this vulnerability to elevate privileges on the system.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-07T07:20:12.446Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000211891/dsa-2023-221-dell-power-manager"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-28051",
        "datePublished": "2023-04-07T07:20:12.446Z",
        "dateReserved": "2023-03-10T05:01:43.871Z",
        "dateUpdated": "2025-02-10T16:10:09.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-49600 (GCVE-0-2024-49600)

    Vulnerability from cvelistv5 – Published: 2024-12-09 14:56 – Updated: 2024-12-10 16:47
    VLAI
    Summary
    Dell Power Manager (DPM), versions prior to 3.17, contain an improper access control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of Privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: N/A , < 3.17 (semver)
    Create a notification for this product.
    Date Public
    2024-12-05 06:30
    Credits
    Dell Technologies would like to thank TsungShu Chiu (CHT Security) for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-49600",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-09T22:09:13.049969Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-10T16:47:12.869Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.17",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank TsungShu Chiu (CHT Security) for reporting this issue."
            }
          ],
          "datePublic": "2024-12-05T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Power Manager (DPM), versions prior to 3.17, contain an improper access control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of Privileges."
                }
              ],
              "value": "Dell Power Manager (DPM), versions prior to 3.17, contain an improper access control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of Privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-09T14:56:34.237Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000244438/dsa-2024-439"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-49600",
        "datePublished": "2024-12-09T14:56:34.237Z",
        "dateReserved": "2024-10-17T05:03:48.988Z",
        "dateUpdated": "2024-12-10T16:47:12.869Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39576 (GCVE-0-2024-39576)

    Vulnerability from cvelistv5 – Published: 2024-08-22 02:54 – Updated: 2024-08-22 13:39
    VLAI
    Summary
    Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: N/A , < 3.16.0 (semver)
    Create a notification for this product.
    dell power_manager Affected: 0 , < 3.16.0 (semver)
        cpe:2.3:a:dell:power_manager:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-08-21 06:30
    Credits
    Dell would like to thank Lefteris Panos from LRQA Nettitude for reporting this issue
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:dell:power_manager:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "power_manager",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "3.16.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39576",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-22T13:35:22.576186Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-22T13:39:02.079Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.16.0",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank Lefteris Panos from LRQA Nettitude for reporting this issue"
            }
          ],
          "datePublic": "2024-08-21T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges."
                }
              ],
              "value": "Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-22T02:54:05.865Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000227010/dsa-2024-323"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-39576",
        "datePublished": "2024-08-22T02:54:05.865Z",
        "dateReserved": "2024-06-26T02:14:30.866Z",
        "dateUpdated": "2024-08-22T13:39:02.079Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25543 (GCVE-0-2023-25543)

    Vulnerability from cvelistv5 – Published: 2024-02-06 06:31 – Updated: 2024-08-02 11:25
    VLAI
    Summary
    Dell Power Manager, versions prior to 3.14, contain an Improper Authorization vulnerability in DPM service. A low privileged malicious user could potentially exploit this vulnerability in order to elevate privileges on the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-280 - Improper Handling of Insufficient Permissions or Privileges
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: 0 , < 3.14 (semver)
    Create a notification for this product.
    Date Public
    2023-04-04 06:30
    Credits
    Cedric Van Bockhaven
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25543",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-02-06T15:42:34.001281Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T17:21:32.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:25:19.264Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000209464/dsa-2023-075"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Cedric Van Bockhaven"
            }
          ],
          "datePublic": "2023-04-04T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Manager, versions prior to 3.14, contain an Improper Authorization vulnerability in DPM service. A low privileged malicious user could potentially exploit this vulnerability in order to elevate privileges on the system. \u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Manager, versions prior to 3.14, contain an Improper Authorization vulnerability in DPM service. A low privileged malicious user could potentially exploit this vulnerability in order to elevate privileges on the system. \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-280",
                  "description": "CWE-280: Improper Handling of Insufficient Permissions or Privileges",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-06T06:31:42.796Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000209464/dsa-2023-075"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-25543",
        "datePublished": "2024-02-06T06:31:20.673Z",
        "dateReserved": "2023-02-07T09:35:27.080Z",
        "dateUpdated": "2024-08-02T11:25:19.264Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32450 (GCVE-0-2023-32450)

    Vulnerability from cvelistv5 – Published: 2023-07-27 04:33 – Updated: 2024-10-15 15:39
    VLAI
    Summary
    Dell Power Manager, Versions 3.3 to 3.14 contains an Improper Access Control vulnerability. A low-privileged malicious user may potentially exploit this vulnerability to perform arbitrary code execution with limited access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-379 - Creation of Temporary File in Directory with Insecure Permissions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: Versions 3.3 to 3.14
    Create a notification for this product.
    Date Public
    2023-07-26 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.020Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000215215/dsa-2023-181-dell-power-manager-security-update-for-an-improper-access-control-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T15:12:45.987656Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T15:39:49.985Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 3.3 to 3.14"
                }
              ]
            }
          ],
          "datePublic": "2023-07-26T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Manager, Versions 3.3 to 3.14 contains an Improper Access Control vulnerability. A low-privileged malicious user may potentially exploit this vulnerability to perform arbitrary code execution with limited access.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Manager, Versions 3.3 to 3.14 contains an Improper Access Control vulnerability. A low-privileged malicious user may potentially exploit this vulnerability to perform arbitrary code execution with limited access.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-379",
                  "description": "CWE-379: Creation of Temporary File in Directory with Insecure Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-27T04:33:21.674Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000215215/dsa-2023-181-dell-power-manager-security-update-for-an-improper-access-control-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32450",
        "datePublished": "2023-07-27T04:33:21.674Z",
        "dateReserved": "2023-05-09T06:02:34.291Z",
        "dateUpdated": "2024-10-15T15:39:49.985Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-28051 (GCVE-0-2023-28051)

    Vulnerability from cvelistv5 – Published: 2023-04-07 07:20 – Updated: 2025-02-10 16:10
    VLAI
    Summary
    Dell Power Manager, versions 3.10 and prior, contains an Improper Access Control vulnerability. A low-privileged attacker could potentially exploit this vulnerability to elevate privileges on the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Power Manager (DPM) Affected: Versions 3.10 and prior
    Create a notification for this product.
    Date Public
    2023-04-06 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:30:24.128Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000211891/dsa-2023-221-dell-power-manager"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-28051",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-10T16:10:05.294743Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-10T16:10:09.477Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Power Manager (DPM)",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 3.10 and prior"
                }
              ]
            }
          ],
          "datePublic": "2023-04-06T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Power Manager, versions 3.10 and prior, contains an Improper Access Control vulnerability. A low-privileged attacker could potentially exploit this vulnerability to elevate privileges on the system.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell Power Manager, versions 3.10 and prior, contains an Improper Access Control vulnerability. A low-privileged attacker could potentially exploit this vulnerability to elevate privileges on the system.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-07T07:20:12.446Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000211891/dsa-2023-221-dell-power-manager"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-28051",
        "datePublished": "2023-04-07T07:20:12.446Z",
        "dateReserved": "2023-03-10T05:01:43.871Z",
        "dateUpdated": "2025-02-10T16:10:09.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }