    3 vulnerabilities found for pm2.5_pm10_monitor_firmware by airveda

    FKIE_CVE-2024-7408

    Vulnerability from fkie_nvd - Published: 2024-08-12 13:38 - Updated: 2026-06-17 08:20
    Summary
    This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Air Quality Monitor PM2.5 PM10",
              "vendor": "Airveda",
              "versions": [
                {
                  "lessThan": "7.4.4.39",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "vdisclose@cert-in.org.in"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:airveda:pm2.5_pm10_monitor_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "97E9A41C-8043-4A2F-8FDD-E61150D06813",
                  "versionEndExcluding": "7.4.4.39",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:airveda:pm2.5_pm10_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0E792875-205F-4485-8FFA-30A5D1A376B0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\n\nSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system."
        },
        {
          "lang": "es",
          "value": "Esta vulnerabilidad existe en Airveda Air Quality Monitor PM2.5 PM10 debido a la transmisi\u00f3n de informaci\u00f3n confidencial en texto plano durante el modo de emparejamiento AP. Un atacante que se encuentre cerca podr\u00eda aprovechar esta vulnerabilidad capturando el tr\u00e1fico Wi-Fi de Airveda-AP. La explotaci\u00f3n exitosa de esta vulnerabilidad podr\u00eda permitir al atacante provocar un ataque Evil Twin en el sistema objetivo."
        }
      ],
      "id": "CVE-2024-7408",
      "lastModified": "2026-06-17T08:20:02.050",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "ADJACENT",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.6,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "HIGH",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "NONE",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "vdisclose@cert-in.org.in",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-7408",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-08-09T15:14:02.118389Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-08-12T13:38:41.777",
      "references": [
        {
          "source": "vdisclose@cert-in.org.in",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0233"
        }
      ],
      "sourceIdentifier": "vdisclose@cert-in.org.in",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-319"
            }
          ],
          "source": "vdisclose@cert-in.org.in",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-319"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2024-7408 (GCVE-0-2024-7408)

    Vulnerability from nvd – Published: 2024-08-09 10:40 – Updated: 2024-08-09 15:14
    VLAI
    Title
    Information Disclosure Vulnerability in Airveda Air Quality Monitor
    Summary
    This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-09 15:14 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    CERT-In CNA under the mitre root
    CNA scorecard A 90/100 over 27 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Airveda Air Quality Monitor PM2.5 PM10 Affected: 0 , < 7.4.4.39 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7408",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-09T15:14:02.118389Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-09T15:14:15.681Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Air Quality Monitor PM2.5 PM10",
              "vendor": "Airveda",
              "versions": [
                {
                  "lessThan": "7.4.4.39",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Anand Agrawal and Dr. Rajib Ranjan Maiti from BITS-Pilani, Hyderabad Campus"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\n\nSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-65",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-65 Sniff Application Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-09T10:40:54.953Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0233"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to patched version 7.4.4.39\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to patched version 7.4.4.39"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Information Disclosure Vulnerability in Airveda Air Quality Monitor",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2024-7408",
        "datePublished": "2024-08-09T10:40:54.953Z",
        "dateReserved": "2024-08-02T10:47:10.549Z",
        "dateUpdated": "2024-08-09T15:14:15.681Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7408 (GCVE-0-2024-7408)

    Vulnerability from cvelistv5 – Published: 2024-08-09 10:40 – Updated: 2024-08-09 15:14
    VLAI
    Title
    Information Disclosure Vulnerability in Airveda Air Quality Monitor
    Summary
    This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-09 15:14 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    CERT-In CNA under the mitre root
    CNA scorecard A 90/100 over 27 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Airveda Air Quality Monitor PM2.5 PM10 Affected: 0 , < 7.4.4.39 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7408",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-09T15:14:02.118389Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-09T15:14:15.681Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Air Quality Monitor PM2.5 PM10",
              "vendor": "Airveda",
              "versions": [
                {
                  "lessThan": "7.4.4.39",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Anand Agrawal and Dr. Rajib Ranjan Maiti from BITS-Pilani, Hyderabad Campus"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\n\nSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-65",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-65 Sniff Application Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-09T10:40:54.953Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0233"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to patched version 7.4.4.39\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to patched version 7.4.4.39"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Information Disclosure Vulnerability in Airveda Air Quality Monitor",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2024-7408",
        "datePublished": "2024-08-09T10:40:54.953Z",
        "dateReserved": "2024-08-02T10:47:10.549Z",
        "dateUpdated": "2024-08-09T15:14:15.681Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }