Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for pharmacymedical_store_point_of_sale_system by sourcecodester

    CVE-2024-36673 (GCVE-0-2024-36673)

    Vulnerability from nvd – Published: 2024-06-07 12:56 – Updated: 2025-02-13 15:59
    VLAI
    Summary
    Sourcecodester Pharmacy/Medical Store Point of Sale System 1.0 is vulnerable SQL Injection via login.php. This vulnerability stems from inadequate validation of user inputs for the email and password parameters, allowing attackers to inject malicious SQL queries.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-16 18:02 UTC
    CWE
    • n/a
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2134 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    sourcecodester pharmacymedical_store_point_of_sale_system Affected: 1.0
        cpe:2.3:a:sourcecodester:pharmacymedical_store_point_of_sale_system:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:37:05.355Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/CveSecLook/cve/issues/39"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:sourcecodester:pharmacymedical_store_point_of_sale_system:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "pharmacymedical_store_point_of_sale_system",
                "vendor": "sourcecodester",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-36673",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-16T18:02:20.871009Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-89",
                    "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-16T18:02:23.620Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Sourcecodester Pharmacy/Medical Store Point of Sale System 1.0 is vulnerable SQL Injection via login.php. This vulnerability stems from inadequate validation of user inputs for the email and password parameters, allowing attackers to inject malicious SQL queries."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-07T12:56:32.780Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/CveSecLook/cve/issues/39"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-36673",
        "datePublished": "2024-06-07T12:56:32.289Z",
        "dateReserved": "2024-05-30T00:00:00.000Z",
        "dateUpdated": "2025-02-13T15:59:28.066Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-36673 (GCVE-0-2024-36673)

    Vulnerability from cvelistv5 – Published: 2024-06-07 12:56 – Updated: 2025-02-13 15:59
    VLAI
    Summary
    Sourcecodester Pharmacy/Medical Store Point of Sale System 1.0 is vulnerable SQL Injection via login.php. This vulnerability stems from inadequate validation of user inputs for the email and password parameters, allowing attackers to inject malicious SQL queries.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-16 18:02 UTC
    CWE
    • n/a
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2134 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    sourcecodester pharmacymedical_store_point_of_sale_system Affected: 1.0
        cpe:2.3:a:sourcecodester:pharmacymedical_store_point_of_sale_system:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:37:05.355Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/CveSecLook/cve/issues/39"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:sourcecodester:pharmacymedical_store_point_of_sale_system:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "pharmacymedical_store_point_of_sale_system",
                "vendor": "sourcecodester",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-36673",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-16T18:02:20.871009Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-89",
                    "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-16T18:02:23.620Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Sourcecodester Pharmacy/Medical Store Point of Sale System 1.0 is vulnerable SQL Injection via login.php. This vulnerability stems from inadequate validation of user inputs for the email and password parameters, allowing attackers to inject malicious SQL queries."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-07T12:56:32.780Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/CveSecLook/cve/issues/39"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-36673",
        "datePublished": "2024-06-07T12:56:32.289Z",
        "dateReserved": "2024-05-30T00:00:00.000Z",
        "dateUpdated": "2025-02-13T15:59:28.066Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }