Search criteria

6 vulnerabilities found for openstage_sip by unify

CVE-2014-9563 (GCVE-0-2014-9563)

Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:47
VLAI?
Summary
CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:47:41.671Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-12T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-9563",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
              "refsource": "CONFIRM",
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
              "refsource": "MISC",
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-9563",
    "datePublished": "2018-04-12T21:00:00",
    "dateReserved": "2015-01-07T00:00:00",
    "dateUpdated": "2024-08-06T13:47:41.671Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8422 (GCVE-0-2014-8422)

Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
VLAI?
Summary
The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.283Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-12T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8422",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
              "refsource": "CONFIRM",
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
              "refsource": "MISC",
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8422",
    "datePublished": "2018-04-12T21:00:00",
    "dateReserved": "2014-10-22T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8421 (GCVE-0-2014-8421)

Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
VLAI?
Summary
Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.296Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-12T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8421",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
              "refsource": "CONFIRM",
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
              "refsource": "MISC",
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8421",
    "datePublished": "2018-04-12T21:00:00",
    "dateReserved": "2014-10-22T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.296Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8422 (GCVE-0-2014-8422)

Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
VLAI?
Summary
The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.283Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-12T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8422",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
              "refsource": "CONFIRM",
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
              "refsource": "MISC",
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8422",
    "datePublished": "2018-04-12T21:00:00",
    "dateReserved": "2014-10-22T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-9563 (GCVE-0-2014-9563)

Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:47
VLAI?
Summary
CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:47:41.671Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-12T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-9563",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
              "refsource": "CONFIRM",
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
              "refsource": "MISC",
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-9563",
    "datePublished": "2018-04-12T21:00:00",
    "dateReserved": "2015-01-07T00:00:00",
    "dateUpdated": "2024-08-06T13:47:41.671Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8421 (GCVE-0-2014-8421)

Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
VLAI?
Summary
Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.296Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-12T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8421",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
              "refsource": "CONFIRM",
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
              "refsource": "MISC",
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8421",
    "datePublished": "2018-04-12T21:00:00",
    "dateReserved": "2014-10-22T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.296Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}