Search

Find a vulnerability

Search criteria

    9 vulnerabilities found for openstage_sip by unify

    FKIE_CVE-2014-9563

    Vulnerability from fkie_nvd - Published: 2018-04-12 21:29 - Updated: 2026-06-17 00:18
    Summary
    CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:unify:openstage_sip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7228102B-6691-4602-A074-11B953C0D681",
                  "versionEndExcluding": "r3.32.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:unify:openstage_20:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E8FFABC-782E-43BB-A402-C20B6B92342A",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:unify:openstage_40:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95BBDFB6-DDA4-4E2C-8DEA-EDD6C07BB0A1",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:unify:openstage_60:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E660AD8F-0961-4BB8-A453-57FFC205C062",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:unify:openscape_desk_phone_ip_sip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CF4C6F5-E9A5-48E1-8E55-0D7204BA2DC3",
                  "versionEndExcluding": "r3.32.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_35g:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96DC9F9D-8C29-4524-9740-5216E93F86FB",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_35g_eco:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D542112-CDD8-4BEA-B52C-507BCC879279",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_55g:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC85895E-4D76-47EF-806D-8B6DB7058D5E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de inyecci\u00f3n CRLF en la interfaz de gesti\u00f3n web (WBM) en dispositivos Unify (anteriormente Siemens) OpenStage SIP y OpenScape Desk Phone IP V3, en versiones anteriores a la R3.32.0, permite que usuarios autenticados remotos modifiquen la contrase\u00f1a root y, en consecuencia, accedan al puerto de depuraci\u00f3n empleando la interfaz en serie mediante el par\u00e1metro ssh-password en page.cmd."
        }
      ],
      "id": "CVE-2014-9563",
      "lastModified": "2026-06-17T00:18:33.610",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-04-12T21:29:00.597",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-93"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2014-8422

    Vulnerability from fkie_nvd - Published: 2018-04-12 21:29 - Updated: 2026-06-17 00:16
    Summary
    The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:unify:openstage_sip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7228102B-6691-4602-A074-11B953C0D681",
                  "versionEndExcluding": "r3.32.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:unify:openstage_20:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E8FFABC-782E-43BB-A402-C20B6B92342A",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:unify:openstage_40:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95BBDFB6-DDA4-4E2C-8DEA-EDD6C07BB0A1",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:unify:openstage_60:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E660AD8F-0961-4BB8-A453-57FFC205C062",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:unify:openscape_desk_phone_ip_sip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CF4C6F5-E9A5-48E1-8E55-0D7204BA2DC3",
                  "versionEndExcluding": "r3.32.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_35g:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96DC9F9D-8C29-4524-9740-5216E93F86FB",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_35g_eco:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D542112-CDD8-4BEA-B52C-507BCC879279",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_55g:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC85895E-4D76-47EF-806D-8B6DB7058D5E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
        },
        {
          "lang": "es",
          "value": "La interfaz de gesti\u00f3n web en dispositivos Unify (anteriormente Siemens) OpenStage SIP y OpenScape Desk Phone IP V3, en versiones anteriores a la R3.32.0, genera cookies de sesi\u00f3n con una entrop\u00eda suficiente. Esto hace que sea m\u00e1s f\u00e1cil que los atacantes remotos secuestren sesiones mediante un ataque de fuerza bruta."
        }
      ],
      "id": "CVE-2014-8422",
      "lastModified": "2026-06-17T00:16:42.453",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-04-12T21:29:00.473",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mitigation",
            "Vendor Advisory"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mitigation",
            "Vendor Advisory"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-331"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2014-8421

    Vulnerability from fkie_nvd - Published: 2018-04-12 21:29 - Updated: 2026-06-17 00:16
    Summary
    Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:unify:openstage_sip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7228102B-6691-4602-A074-11B953C0D681",
                  "versionEndExcluding": "r3.32.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:unify:openstage_20:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E8FFABC-782E-43BB-A402-C20B6B92342A",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:unify:openstage_40:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95BBDFB6-DDA4-4E2C-8DEA-EDD6C07BB0A1",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:unify:openstage_60:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E660AD8F-0961-4BB8-A453-57FFC205C062",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:unify:openscape_desk_phone_ip_sip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CF4C6F5-E9A5-48E1-8E55-0D7204BA2DC3",
                  "versionEndExcluding": "r3.32.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_35g:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96DC9F9D-8C29-4524-9740-5216E93F86FB",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_35g_eco:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D542112-CDD8-4BEA-B52C-507BCC879279",
                  "vulnerable": false
                },
                {
                  "criteria": "cpe:2.3:h:atos:openscape_desk_phone_ip_55g:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC85895E-4D76-47EF-806D-8B6DB7058D5E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
        },
        {
          "lang": "es",
          "value": "Los dispositivos Unify (anteriormente Siemens) OpenStage SIP y OpenScape Desk Phone IP V3, en versiones anteriores a la R3.32.0, permiten que atacantes remotos obtengan privilegios de superusuario aprovechando el acceso SSH y la propiedad incorrecta de (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh o (20) appWeb en /Opera_Deploy."
        }
      ],
      "id": "CVE-2014-8421",
      "lastModified": "2026-06-17T00:16:42.337",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 8.5,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.6,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-04-12T21:29:00.427",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mitigation",
            "Vendor Advisory"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mitigation",
            "Vendor Advisory"
          ],
          "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-264"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2014-9563 (GCVE-0-2014-9563)

    Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:47
    VLAI
    Summary
    CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 30/100 over 2038 records in the last 180 days details
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:47:41.671Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-9563",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-9563",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2015-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:47:41.671Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8422 (GCVE-0-2014-8422)

    Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 30/100 over 2038 records in the last 180 days details
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.283Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8422",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8422",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.283Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8421 (GCVE-0-2014-8421)

    Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 30/100 over 2038 records in the last 180 days details
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.296Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8421",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8421",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.296Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8421 (GCVE-0-2014-8421)

    Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 30/100 over 2038 records in the last 180 days details
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.296Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8421",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8421",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.296Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-9563 (GCVE-0-2014-9563)

    Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:47
    VLAI
    Summary
    CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 30/100 over 2038 records in the last 180 days details
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:47:41.671Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-9563",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-9563",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2015-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:47:41.671Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8422 (GCVE-0-2014-8422)

    Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 30/100 over 2038 records in the last 180 days details
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.283Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8422",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8422",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.283Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }