    CVE-2014-9563 (GCVE-0-2014-9563)

    Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:47
    VLAI
    Summary
    CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:47:41.671Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-9563",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-9563",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2015-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:47:41.671Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8422 (GCVE-0-2014-8422)

    Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.283Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8422",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8422",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.283Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8421 (GCVE-0-2014-8421)

    Vulnerability from nvd – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.296Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8421",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8421",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.296Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-9563 (GCVE-0-2014-9563)

    Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:47
    VLAI
    Summary
    CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:47:41.671Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-9563",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CRLF injection vulnerability in the web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allows remote authenticated users to modify the root password and consequently access the debug port using the serial interface via the ssh-password parameter to page.cmd."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-9563",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2015-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:47:41.671Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8421 (GCVE-0-2014-8421)

    Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.296Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8421",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8421",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.296Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-8422 (GCVE-0-2014-8422)

    Vulnerability from cvelistv5 – Published: 2018-04-12 21:00 – Updated: 2024-08-06 13:18
    VLAI
    Summary
    The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-02-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:18:48.283Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-02-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-12T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2014-8422",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The web-based management (WBM) interface in Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 generates session cookies with insufficient entropy, which makes it easier for remote attackers to hijack sessions via a brute-force attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
                },
                {
                  "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                  "refsource": "MISC",
                  "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2014-8422",
        "datePublished": "2018-04-12T21:00:00.000Z",
        "dateReserved": "2014-10-22T00:00:00.000Z",
        "dateUpdated": "2024-08-06T13:18:48.283Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }