Search criteria

8 vulnerabilities found for open_sdn_controller by projectfloodlight

CVE-2024-51406 (GCVE-0-2024-51406)

Vulnerability from nvd – Published: 2024-11-01 00:00 – Updated: 2024-11-04 19:11
VLAI?
Summary
Floodlight SDN Open Flow Controller v.1.2 has an issue that allows local hosts to build fake LLDP packets that allow specific clusters to be missed by Floodlight, which in turn leads to missed hosts inside and outside the cluster.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:projectfloodlight:floodlight:1.2:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "floodlight",
            "vendor": "projectfloodlight",
            "versions": [
              {
                "status": "affected",
                "version": "1.2"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.2,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-51406",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-04T19:08:24.437669Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "description": "CWE-noinfo Not enough information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-04T19:11:07.872Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Floodlight SDN Open Flow Controller v.1.2 has an issue that allows local hosts to build fake LLDP packets that allow specific clusters to be missed by Floodlight, which in turn leads to missed hosts inside and outside the cluster."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-01T13:30:21.035882",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/floodlight/floodlight/issues/870"
        },
        {
          "url": "https://ieeexplore.ieee.org/document/10246976"
        },
        {
          "url": "https://github.com/floodlight/floodlight"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-51406",
    "datePublished": "2024-11-01T00:00:00",
    "dateReserved": "2024-10-28T00:00:00",
    "dateUpdated": "2024-11-04T19:11:07.872Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29461 (GCVE-0-2024-29461)

Vulnerability from nvd – Published: 2024-04-12 00:00 – Updated: 2025-03-17 15:19
VLAI?
Summary
An issue in Floodlight SDN OpenFlow Controller v.1.2 allows a remote attacker to cause a denial of service via the datapath id component.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:atlassian:floodlight_controller:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "floodlight_controller",
            "vendor": "atlassian",
            "versions": [
              {
                "status": "affected",
                "version": "v.1.2"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-29461",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-10T16:44:16.801677Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-17T15:19:58.624Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:55.382Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/floodlight/floodlight/issues/867"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://gist.github.com/ErodedElk/399a226905c574efe705e3bff77955e3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in Floodlight SDN OpenFlow Controller v.1.2 allows a remote attacker to cause a denial of service via the datapath id component."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-12T13:58:23.045Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/floodlight/floodlight/issues/867"
        },
        {
          "url": "https://gist.github.com/ErodedElk/399a226905c574efe705e3bff77955e3"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-29461",
    "datePublished": "2024-04-12T00:00:00.000Z",
    "dateReserved": "2024-03-19T00:00:00.000Z",
    "dateUpdated": "2025-03-17T15:19:58.624Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-2304 (GCVE-0-2014-2304)

Vulnerability from nvd – Published: 2019-10-23 17:01 – Updated: 2024-08-06 10:06
VLAI?
Summary
A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:06:00.338Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T17:01:41",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-2304",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf",
              "refsource": "MISC",
              "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-2304",
    "datePublished": "2019-10-23T17:01:41",
    "dateReserved": "2014-03-06T00:00:00",
    "dateUpdated": "2024-08-06T10:06:00.338Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-7333 (GCVE-0-2013-7333)

Vulnerability from nvd – Published: 2019-10-23 16:46 – Updated: 2024-08-06 18:01
VLAI?
Summary
A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T18:01:20.593Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T16:46:21",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-7333",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf",
              "refsource": "MISC",
              "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-7333",
    "datePublished": "2019-10-23T16:46:21",
    "dateReserved": "2014-03-06T00:00:00",
    "dateUpdated": "2024-08-06T18:01:20.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-51406 (GCVE-0-2024-51406)

Vulnerability from cvelistv5 – Published: 2024-11-01 00:00 – Updated: 2024-11-04 19:11
VLAI?
Summary
Floodlight SDN Open Flow Controller v.1.2 has an issue that allows local hosts to build fake LLDP packets that allow specific clusters to be missed by Floodlight, which in turn leads to missed hosts inside and outside the cluster.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:projectfloodlight:floodlight:1.2:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "floodlight",
            "vendor": "projectfloodlight",
            "versions": [
              {
                "status": "affected",
                "version": "1.2"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.2,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-51406",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-04T19:08:24.437669Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "description": "CWE-noinfo Not enough information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-04T19:11:07.872Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Floodlight SDN Open Flow Controller v.1.2 has an issue that allows local hosts to build fake LLDP packets that allow specific clusters to be missed by Floodlight, which in turn leads to missed hosts inside and outside the cluster."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-01T13:30:21.035882",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/floodlight/floodlight/issues/870"
        },
        {
          "url": "https://ieeexplore.ieee.org/document/10246976"
        },
        {
          "url": "https://github.com/floodlight/floodlight"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-51406",
    "datePublished": "2024-11-01T00:00:00",
    "dateReserved": "2024-10-28T00:00:00",
    "dateUpdated": "2024-11-04T19:11:07.872Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29461 (GCVE-0-2024-29461)

Vulnerability from cvelistv5 – Published: 2024-04-12 00:00 – Updated: 2025-03-17 15:19
VLAI?
Summary
An issue in Floodlight SDN OpenFlow Controller v.1.2 allows a remote attacker to cause a denial of service via the datapath id component.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:atlassian:floodlight_controller:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "floodlight_controller",
            "vendor": "atlassian",
            "versions": [
              {
                "status": "affected",
                "version": "v.1.2"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-29461",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-10T16:44:16.801677Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-17T15:19:58.624Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:55.382Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/floodlight/floodlight/issues/867"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://gist.github.com/ErodedElk/399a226905c574efe705e3bff77955e3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in Floodlight SDN OpenFlow Controller v.1.2 allows a remote attacker to cause a denial of service via the datapath id component."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-12T13:58:23.045Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/floodlight/floodlight/issues/867"
        },
        {
          "url": "https://gist.github.com/ErodedElk/399a226905c574efe705e3bff77955e3"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-29461",
    "datePublished": "2024-04-12T00:00:00.000Z",
    "dateReserved": "2024-03-19T00:00:00.000Z",
    "dateUpdated": "2025-03-17T15:19:58.624Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-2304 (GCVE-0-2014-2304)

Vulnerability from cvelistv5 – Published: 2019-10-23 17:01 – Updated: 2024-08-06 10:06
VLAI?
Summary
A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:06:00.338Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T17:01:41",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-2304",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf",
              "refsource": "MISC",
              "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-2304",
    "datePublished": "2019-10-23T17:01:41",
    "dateReserved": "2014-03-06T00:00:00",
    "dateUpdated": "2024-08-06T10:06:00.338Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-7333 (GCVE-0-2013-7333)

Vulnerability from cvelistv5 – Published: 2019-10-23 16:46 – Updated: 2024-08-06 18:01
VLAI?
Summary
A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T18:01:20.593Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T16:46:21",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-7333",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices connected to the targeted switch."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf",
              "refsource": "MISC",
              "url": "http://dovernetworks.com/wp-content/uploads/2013/12/OpenFloodlight-12302013.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-7333",
    "datePublished": "2019-10-23T16:46:21",
    "dateReserved": "2014-03-06T00:00:00",
    "dateUpdated": "2024-08-06T18:01:20.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}