    Summary
    This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537 [with vendor rollup]. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of certificates. A crafted certificate can force the server into an infinite loop. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-17203.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
    Assigner
    zdi
    Impacted products
    Vendor Product Version
    Unified Automation OPC UA C++ Demo Server Affected: 1.7.6-537 [with vendor rollup]
    Create a notification for this product.
    Credits
    Daan Keuper & Thijs Alkemade from Computest
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:21:32.556Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1029/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-37013",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-18T19:32:33.324188Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-18T19:32:44.598Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC UA C++ Demo Server",
              "vendor": "Unified Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.7.6-537 [with vendor rollup]"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Daan Keuper \u0026 Thijs Alkemade from Computest"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537 [with vendor rollup]. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of certificates. A crafted certificate can force the server into an infinite loop. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-17203."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-835",
                  "description": "CWE-835: Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-29T00:00:00.000Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
            },
            {
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1029/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2022-37013",
        "datePublished": "2023-03-29T00:00:00.000Z",
        "dateReserved": "2022-07-28T00:00:00.000Z",
        "dateUpdated": "2025-02-18T19:32:44.598Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-37012 (GCVE-0-2022-37012)

    Vulnerability from nvd – Published: 2023-03-29 00:00 – Updated: 2025-02-18 19:34
    VLAI
    Summary
    This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-911 - Improper Update of Reference Count
    Assigner
    zdi
    Impacted products
    Credits
    20urdjk
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:21:32.458Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-37012",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-18T19:34:15.764429Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-18T19:34:23.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC UA C++ Demo Server",
              "vendor": "Unified Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.7.6-537"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "20urdjk"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-911",
                  "description": "CWE-911: Improper Update of Reference Count",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-29T00:00:00.000Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/"
            },
            {
              "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2022-37012",
        "datePublished": "2023-03-29T00:00:00.000Z",
        "dateReserved": "2022-07-28T00:00:00.000Z",
        "dateUpdated": "2025-02-18T19:34:23.714Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-37013 (GCVE-0-2022-37013)

    Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 19:32
    VLAI
    Summary
    This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537 [with vendor rollup]. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of certificates. A crafted certificate can force the server into an infinite loop. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-17203.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
    Assigner
    zdi
    Impacted products
    Vendor Product Version
    Unified Automation OPC UA C++ Demo Server Affected: 1.7.6-537 [with vendor rollup]
    Create a notification for this product.
    Credits
    Daan Keuper & Thijs Alkemade from Computest
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:21:32.556Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1029/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-37013",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-18T19:32:33.324188Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-18T19:32:44.598Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC UA C++ Demo Server",
              "vendor": "Unified Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.7.6-537 [with vendor rollup]"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Daan Keuper \u0026 Thijs Alkemade from Computest"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537 [with vendor rollup]. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of certificates. A crafted certificate can force the server into an infinite loop. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-17203."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-835",
                  "description": "CWE-835: Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-29T00:00:00.000Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
            },
            {
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1029/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2022-37013",
        "datePublished": "2023-03-29T00:00:00.000Z",
        "dateReserved": "2022-07-28T00:00:00.000Z",
        "dateUpdated": "2025-02-18T19:32:44.598Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-37012 (GCVE-0-2022-37012)

    Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 19:34
    VLAI
    Summary
    This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-911 - Improper Update of Reference Count
    Assigner
    zdi
    Impacted products
    Credits
    20urdjk
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:21:32.458Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-37012",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-18T19:34:15.764429Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-18T19:34:23.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC UA C++ Demo Server",
              "vendor": "Unified Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.7.6-537"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "20urdjk"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-911",
                  "description": "CWE-911: Improper Update of Reference Count",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-29T00:00:00.000Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/"
            },
            {
              "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2022-37012",
        "datePublished": "2023-03-29T00:00:00.000Z",
        "dateReserved": "2022-07-28T00:00:00.000Z",
        "dateUpdated": "2025-02-18T19:34:23.714Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }