CVE-2016-5819 (GCVE-0-2016-5819)
Vulnerability from nvd – Published: 2019-03-21 13:23 – Updated: 2024-08-06 01:15
VLAI?
Summary
Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user’s browser within the trust relationship between their browser and the server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Cross-site scripting CWE-79
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Moxa | OnCell G3100V2 Series |
Affected:
< 2.8
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:15:10.044Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OnCell G3100V2 Series",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "\u003c 2.8"
}
]
},
{
"product": "OnCell G3111/G3151/G3211/G3251 Series",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "\u003c 1.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross-site scripting CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-21T13:23:04",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2016-5819",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OnCell G3100V2 Series",
"version": {
"version_data": [
{
"version_value": "\u003c 2.8"
}
]
}
}
]
},
"vendor_name": "Moxa"
},
{
"product": {
"product_data": [
{
"product_name": "OnCell G3111/G3151/G3211/G3251 Series",
"version": {
"version_data": [
{
"version_value": "\u003c 1.7"
}
]
}
}
]
},
"vendor_name": "Moxa"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-site scripting CWE-79"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2016-5819",
"datePublished": "2019-03-21T13:23:04",
"dateReserved": "2016-06-23T00:00:00",
"dateUpdated": "2024-08-06T01:15:10.044Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-5812 (GCVE-0-2016-5812)
Vulnerability from nvd – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
VLAI?
Summary
Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:15:10.727Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/92605"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-08-23T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-11-25T19:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/92605"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2016-5812",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/92605"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2016-5812",
"datePublished": "2016-08-24T01:00:00",
"dateReserved": "2016-06-23T00:00:00",
"dateUpdated": "2024-08-06T01:15:10.727Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-5799 (GCVE-0-2016-5799)
Vulnerability from nvd – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
VLAI?
Summary
Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:15:08.989Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92606",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/92606"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-08-23T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-11-25T19:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92606",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/92606"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2016-5799",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92606",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/92606"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2016-5799",
"datePublished": "2016-08-24T01:00:00",
"dateReserved": "2016-06-23T00:00:00",
"dateUpdated": "2024-08-06T01:15:08.989Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-5819 (GCVE-0-2016-5819)
Vulnerability from cvelistv5 – Published: 2019-03-21 13:23 – Updated: 2024-08-06 01:15
VLAI?
Summary
Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user’s browser within the trust relationship between their browser and the server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Cross-site scripting CWE-79
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Moxa | OnCell G3100V2 Series |
Affected:
< 2.8
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:15:10.044Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OnCell G3100V2 Series",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "\u003c 2.8"
}
]
},
{
"product": "OnCell G3111/G3151/G3211/G3251 Series",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "\u003c 1.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross-site scripting CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-21T13:23:04",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2016-5819",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OnCell G3100V2 Series",
"version": {
"version_data": [
{
"version_value": "\u003c 2.8"
}
]
}
}
]
},
"vendor_name": "Moxa"
},
{
"product": {
"product_data": [
{
"product_name": "OnCell G3111/G3151/G3211/G3251 Series",
"version": {
"version_data": [
{
"version_value": "\u003c 1.7"
}
]
}
}
]
},
"vendor_name": "Moxa"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-site scripting CWE-79"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2016-5819",
"datePublished": "2019-03-21T13:23:04",
"dateReserved": "2016-06-23T00:00:00",
"dateUpdated": "2024-08-06T01:15:10.044Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-5799 (GCVE-0-2016-5799)
Vulnerability from cvelistv5 – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
VLAI?
Summary
Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:15:08.989Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92606",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/92606"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-08-23T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-11-25T19:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92606",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/92606"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2016-5799",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92606",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/92606"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2016-5799",
"datePublished": "2016-08-24T01:00:00",
"dateReserved": "2016-06-23T00:00:00",
"dateUpdated": "2024-08-06T01:15:08.989Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-5812 (GCVE-0-2016-5812)
Vulnerability from cvelistv5 – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
VLAI?
Summary
Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:15:10.727Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/92605"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-08-23T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-11-25T19:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/92605"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2016-5812",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
},
{
"name": "92605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/92605"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2016-5812",
"datePublished": "2016-08-24T01:00:00",
"dateReserved": "2016-06-23T00:00:00",
"dateUpdated": "2024-08-06T01:15:10.727Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}