Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for oncell_g3100v2_firmware by moxa

    CVE-2016-5819 (GCVE-0-2016-5819)

    Vulnerability from nvd – Published: 2019-03-21 13:23 – Updated: 2024-08-06 01:15
    VLAI
    Summary
    Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user’s browser within the trust relationship between their browser and the server.
    Severity
    No CVSS data available.
    CWE
    • CWE-79 - Cross-site scripting CWE-79
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T01:15:10.044Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OnCell G3100V2 Series",
              "vendor": "Moxa",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 2.8"
                }
              ]
            },
            {
              "product": "OnCell G3111/G3151/G3211/G3251 Series",
              "vendor": "Moxa",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 1.7"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "Cross-site scripting CWE-79",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-03-21T13:23:04.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2016-5819",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OnCell G3100V2 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "\u003c 2.8"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Moxa"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OnCell G3111/G3151/G3211/G3251 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "\u003c 1.7"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Moxa"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site scripting CWE-79"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2016-5819",
        "datePublished": "2019-03-21T13:23:04.000Z",
        "dateReserved": "2016-06-23T00:00:00.000Z",
        "dateUpdated": "2024-08-06T01:15:10.044Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2016-5812 (GCVE-0-2016-5812)

    Vulnerability from nvd – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
    VLAI
    Summary
    Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2016-08-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T01:15:10.727Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
              },
              {
                "name": "92605",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/92605"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2016-08-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2016-11-25T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
            },
            {
              "name": "92605",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/92605"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2016-5812",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
                },
                {
                  "name": "92605",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/92605"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2016-5812",
        "datePublished": "2016-08-24T01:00:00.000Z",
        "dateReserved": "2016-06-23T00:00:00.000Z",
        "dateUpdated": "2024-08-06T01:15:10.727Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2016-5799 (GCVE-0-2016-5799)

    Vulnerability from nvd – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
    VLAI
    Summary
    Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2016-08-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T01:15:08.989Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
              },
              {
                "name": "92606",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/92606"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2016-08-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2016-11-25T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
            },
            {
              "name": "92606",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/92606"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2016-5799",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
                },
                {
                  "name": "92606",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/92606"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2016-5799",
        "datePublished": "2016-08-24T01:00:00.000Z",
        "dateReserved": "2016-06-23T00:00:00.000Z",
        "dateUpdated": "2024-08-06T01:15:08.989Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2016-5819 (GCVE-0-2016-5819)

    Vulnerability from cvelistv5 – Published: 2019-03-21 13:23 – Updated: 2024-08-06 01:15
    VLAI
    Summary
    Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user’s browser within the trust relationship between their browser and the server.
    Severity
    No CVSS data available.
    CWE
    • CWE-79 - Cross-site scripting CWE-79
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T01:15:10.044Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OnCell G3100V2 Series",
              "vendor": "Moxa",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 2.8"
                }
              ]
            },
            {
              "product": "OnCell G3111/G3151/G3211/G3251 Series",
              "vendor": "Moxa",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 1.7"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "Cross-site scripting CWE-79",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-03-21T13:23:04.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2016-5819",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OnCell G3100V2 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "\u003c 2.8"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Moxa"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OnCell G3111/G3151/G3211/G3251 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "\u003c 1.7"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Moxa"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user\u2019s browser within the trust relationship between their browser and the server."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site scripting CWE-79"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2016-5819",
        "datePublished": "2019-03-21T13:23:04.000Z",
        "dateReserved": "2016-06-23T00:00:00.000Z",
        "dateUpdated": "2024-08-06T01:15:10.044Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2016-5812 (GCVE-0-2016-5812)

    Vulnerability from cvelistv5 – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
    VLAI
    Summary
    Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2016-08-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T01:15:10.727Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
              },
              {
                "name": "92605",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/92605"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2016-08-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2016-11-25T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
            },
            {
              "name": "92605",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/92605"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2016-5812",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
                },
                {
                  "name": "92605",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/92605"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2016-5812",
        "datePublished": "2016-08-24T01:00:00.000Z",
        "dateReserved": "2016-06-23T00:00:00.000Z",
        "dateUpdated": "2024-08-06T01:15:10.727Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2016-5799 (GCVE-0-2016-5799)

    Vulnerability from cvelistv5 – Published: 2016-08-24 01:00 – Updated: 2024-08-06 01:15
    VLAI
    Summary
    Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2016-08-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T01:15:08.989Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
              },
              {
                "name": "92606",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/92606"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2016-08-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2016-11-25T19:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
            },
            {
              "name": "92606",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/92606"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2016-5799",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-236-01"
                },
                {
                  "name": "92606",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/92606"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2016-5799",
        "datePublished": "2016-08-24T01:00:00.000Z",
        "dateReserved": "2016-06-23T00:00:00.000Z",
        "dateUpdated": "2024-08-06T01:15:08.989Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }