Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for o6 by tenda

    VAR-202408-2381

    Vulnerability from variot - Updated: 2024-10-18 23:24

    A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter ip/localPort/publicPort/app of the fromVirtualSet function of the file/goform/setPortForward failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202408-2381",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "o6",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.7\\(2054\\)"
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "o6  firmware  1.0.0.7(2054)"
          },
          {
            "model": "o6",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.7"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "cve": "CVE-2024-8231",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-8231",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-010440",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-40457",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-8231",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-010440",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-8231",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-8231",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-010440",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-40457",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter ip/localPort/publicPort/app of the fromVirtualSet function of the file/goform/setPortForward failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-8231",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "275940",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "id": "VAR-202408-2381",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          }
        ]
      },
      "last_update_date": "2024-10-18T23:24:44.894000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/abcdefg-png/ahu-iot-vulnerable/blob/main/tenda/web-bridge/o6v3.0/fromvirtualset.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.275940"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.394032"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-8231"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.275940"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          },
          {
            "date": "2024-10-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "date": "2024-08-28T02:15:04.160000",
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40457"
          },
          {
            "date": "2024-10-17T01:37:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          },
          {
            "date": "2024-10-16T20:01:30.877000",
            "db": "NVD",
            "id": "CVE-2024-8231"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0o6\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-010440"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202409-1200

    Vulnerability from variot - Updated: 2024-10-13 23:19

    Tenda O6 V3.0 firmware V1.0.0.7(2054) contains a stack overflow vulnerability in the formexeCommand function. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda O6 is a wireless bridge from China's Tenda company. No detailed vulnerability details are currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202409-1200",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "o6",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.7\\(2054\\)"
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "o6  firmware  1.0.0.7(2054)"
          },
          {
            "model": "o6",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.7"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "cve": "CVE-2024-46049",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2024-40284",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-46049",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.1,
                "id": "CVE-2024-46049",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2024-46049",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-46049",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-46049",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2024-46049",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-40284",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda O6 V3.0 firmware V1.0.0.7(2054) contains a stack overflow vulnerability in the formexeCommand function. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda O6 is a wireless bridge from China\u0027s Tenda company. No detailed vulnerability details are currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-46049",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "id": "VAR-202409-1200",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          }
        ]
      },
      "last_update_date": "2024-10-13T23:19:26.758000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda O6 has an unspecified vulnerability (CNVD-2024-40284)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/598776"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/benjpopo/v/blob/main/tenda/o6/formexecommand.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-46049"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          },
          {
            "date": "2024-09-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "date": "2024-09-13T14:15:14.477000",
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40284"
          },
          {
            "date": "2024-09-25T00:54:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          },
          {
            "date": "2024-09-20T00:39:30.443000",
            "db": "NVD",
            "id": "CVE-2024-46049"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0o6\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-008801"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202408-2365

    Vulnerability from variot - Updated: 2024-10-13 23:10

    A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter mac of the frommacFilterModify function in the file /goform/operateMacFilter failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202408-2365",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "o6",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.7\\(2054\\)"
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "o6  firmware  1.0.0.7(2054)"
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.7"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "cve": "CVE-2024-8229",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-8229",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-006926",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-40455",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-8229",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-8229",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-006926",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-8229",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-8229",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-006926",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-40455",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter mac of the frommacFilterModify function in the file /goform/operateMacFilter failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-8229",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "275938",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "id": "VAR-202408-2365",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          }
        ]
      },
      "last_update_date": "2024-10-13T23:10:36.583000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/abcdefg-png/ahu-iot-vulnerable/blob/main/tenda/web-bridge/o6v3.0/frommacfiltermodify.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.275938"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.394030"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-8229"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.275938"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          },
          {
            "date": "2024-08-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "date": "2024-08-28T01:15:03.353000",
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40455"
          },
          {
            "date": "2024-08-30T02:38:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          },
          {
            "date": "2024-08-29T00:10:09.807000",
            "db": "NVD",
            "id": "CVE-2024-8229"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0o6\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006926"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202408-2352

    Vulnerability from variot - Updated: 2024-10-13 22:51

    A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter remark/type/time of the fromSafeSetMacFilter function in the file/goform/setMacFilterList failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202408-2352",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "o6",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.7\\(2054\\)"
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "o6  firmware  1.0.0.7(2054)"
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "o6",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.7"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "cve": "CVE-2024-8230",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-8230",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-006962",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-40456",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-8230",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-8230",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-006962",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-8230",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-8230",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-006962",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-40456",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of o6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter remark/type/time of the fromSafeSetMacFilter function in the file/goform/setMacFilterList failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-8230",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "275939",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "id": "VAR-202408-2352",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          }
        ]
      },
      "last_update_date": "2024-10-13T22:51:15.690000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/abcdefg-png/ahu-iot-vulnerable/blob/main/tenda/web-bridge/o6v3.0/fromsafesetmacfilter.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.275939"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.394031"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-8230"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.275939"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          },
          {
            "date": "2024-09-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "date": "2024-08-28T02:15:03.850000",
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-10-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-40456"
          },
          {
            "date": "2024-09-02T01:30:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          },
          {
            "date": "2024-08-29T00:08:24.643000",
            "db": "NVD",
            "id": "CVE-2024-8230"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0o6\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-006962"
          }
        ],
        "trust": 0.8
      }
    }

    CVE-2024-8231 (GCVE-0-2024-8231)

    Vulnerability from nvd – Published: 2024-08-28 01:00 – Updated: 2024-08-28 15:52
    VLAI
    Title
    Tenda O6 setPortForward fromVirtualSet stack-based overflow
    Summary
    A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.275940 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.275940 signaturepermissions-required
    https://vuldb.com/?submit.394032 third-party-advisory
    https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda O6 Affected: 1.0.0.7(2054)
    Create a notification for this product.
    tenda o6_firmware Affected: 1.0.0.7\(2054\)
        cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    yhryhryhr_miemie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "o6_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.7\\(2054\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8231",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-28T15:48:19.341160Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T15:52:09.155Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "O6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7(2054)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda O6 1.0.0.7(2054) entdeckt. Es betrifft die Funktion fromVirtualSet der Datei /goform/setPortForward. Mittels dem Manipulieren des Arguments ip/localPort/publicPort/app mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-28T01:00:09.903Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-275940 | Tenda O6 setPortForward fromVirtualSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.275940"
            },
            {
              "name": "VDB-275940 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.275940"
            },
            {
              "name": "Submit #394032 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.394032"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromVirtualSet.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-27T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-27T15:17:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda O6 setPortForward fromVirtualSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8231",
        "datePublished": "2024-08-28T01:00:09.903Z",
        "dateReserved": "2024-08-27T13:12:21.701Z",
        "dateUpdated": "2024-08-28T15:52:09.155Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-8230 (GCVE-0-2024-8230)

    Vulnerability from nvd – Published: 2024-08-28 01:00 – Updated: 2024-08-28 15:53
    VLAI
    Title
    Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow
    Summary
    A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.275939 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.275939 signaturepermissions-required
    https://vuldb.com/?submit.394031 third-party-advisory
    https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda O6 Affected: 1.0.0.7(2054)
    Create a notification for this product.
    tenda o6_firmware Affected: 1.0.0.7\(2054\)
        cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    yhryhryhr_miemie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "o6_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.7\\(2054\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8230",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-28T15:52:54.234842Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T15:53:48.670Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "O6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7(2054)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda O6 1.0.0.7(2054) ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterList. Durch Manipulation des Arguments remark/type/time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-28T01:00:07.395Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-275939 | Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.275939"
            },
            {
              "name": "VDB-275939 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.275939"
            },
            {
              "name": "Submit #394031 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.394031"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromSafeSetMacFilter.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-27T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-27T15:17:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8230",
        "datePublished": "2024-08-28T01:00:07.395Z",
        "dateReserved": "2024-08-27T13:12:18.685Z",
        "dateUpdated": "2024-08-28T15:53:48.670Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-8229 (GCVE-0-2024-8229)

    Vulnerability from nvd – Published: 2024-08-28 00:31 – Updated: 2024-08-28 15:54
    VLAI
    Title
    Tenda O6 operateMacFilter frommacFilterModify stack-based overflow
    Summary
    A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.275938 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.275938 signaturepermissions-required
    https://vuldb.com/?submit.394030 third-party-advisory
    https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda O6 Affected: 1.0.0.7(2054)
    Create a notification for this product.
    tenda o6_firmware Affected: 1.0.0.7\(2054\)
        cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    yhryhryhr_miemie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "o6_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.7\\(2054\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8229",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-28T15:54:16.386339Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T15:54:55.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "O6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7(2054)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda O6 1.0.0.7(2054) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion frommacFilterModify der Datei /goform/operateMacFilter. Durch die Manipulation des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-28T00:31:05.407Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-275938 | Tenda O6 operateMacFilter frommacFilterModify stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.275938"
            },
            {
              "name": "VDB-275938 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.275938"
            },
            {
              "name": "Submit #394030 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.394030"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromMacFilterModify.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-27T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-27T15:17:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda O6 operateMacFilter frommacFilterModify stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8229",
        "datePublished": "2024-08-28T00:31:05.407Z",
        "dateReserved": "2024-08-27T13:12:15.785Z",
        "dateUpdated": "2024-08-28T15:54:55.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-8231 (GCVE-0-2024-8231)

    Vulnerability from cvelistv5 – Published: 2024-08-28 01:00 – Updated: 2024-08-28 15:52
    VLAI
    Title
    Tenda O6 setPortForward fromVirtualSet stack-based overflow
    Summary
    A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.275940 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.275940 signaturepermissions-required
    https://vuldb.com/?submit.394032 third-party-advisory
    https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda O6 Affected: 1.0.0.7(2054)
    Create a notification for this product.
    tenda o6_firmware Affected: 1.0.0.7\(2054\)
        cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    yhryhryhr_miemie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "o6_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.7\\(2054\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8231",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-28T15:48:19.341160Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T15:52:09.155Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "O6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7(2054)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda O6 1.0.0.7(2054) entdeckt. Es betrifft die Funktion fromVirtualSet der Datei /goform/setPortForward. Mittels dem Manipulieren des Arguments ip/localPort/publicPort/app mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-28T01:00:09.903Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-275940 | Tenda O6 setPortForward fromVirtualSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.275940"
            },
            {
              "name": "VDB-275940 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.275940"
            },
            {
              "name": "Submit #394032 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.394032"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromVirtualSet.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-27T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-27T15:17:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda O6 setPortForward fromVirtualSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8231",
        "datePublished": "2024-08-28T01:00:09.903Z",
        "dateReserved": "2024-08-27T13:12:21.701Z",
        "dateUpdated": "2024-08-28T15:52:09.155Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-8230 (GCVE-0-2024-8230)

    Vulnerability from cvelistv5 – Published: 2024-08-28 01:00 – Updated: 2024-08-28 15:53
    VLAI
    Title
    Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow
    Summary
    A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.275939 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.275939 signaturepermissions-required
    https://vuldb.com/?submit.394031 third-party-advisory
    https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda O6 Affected: 1.0.0.7(2054)
    Create a notification for this product.
    tenda o6_firmware Affected: 1.0.0.7\(2054\)
        cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    yhryhryhr_miemie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "o6_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.7\\(2054\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8230",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-28T15:52:54.234842Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T15:53:48.670Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "O6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7(2054)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda O6 1.0.0.7(2054) ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterList. Durch Manipulation des Arguments remark/type/time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-28T01:00:07.395Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-275939 | Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.275939"
            },
            {
              "name": "VDB-275939 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.275939"
            },
            {
              "name": "Submit #394031 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.394031"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromSafeSetMacFilter.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-27T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-27T15:17:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8230",
        "datePublished": "2024-08-28T01:00:07.395Z",
        "dateReserved": "2024-08-27T13:12:18.685Z",
        "dateUpdated": "2024-08-28T15:53:48.670Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-8229 (GCVE-0-2024-8229)

    Vulnerability from cvelistv5 – Published: 2024-08-28 00:31 – Updated: 2024-08-28 15:54
    VLAI
    Title
    Tenda O6 operateMacFilter frommacFilterModify stack-based overflow
    Summary
    A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.275938 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.275938 signaturepermissions-required
    https://vuldb.com/?submit.394030 third-party-advisory
    https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda O6 Affected: 1.0.0.7(2054)
    Create a notification for this product.
    tenda o6_firmware Affected: 1.0.0.7\(2054\)
        cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    yhryhryhr_miemie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "o6_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.7\\(2054\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8229",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-28T15:54:16.386339Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T15:54:55.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "O6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.7(2054)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda O6 1.0.0.7(2054) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion frommacFilterModify der Datei /goform/operateMacFilter. Durch die Manipulation des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-28T00:31:05.407Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-275938 | Tenda O6 operateMacFilter frommacFilterModify stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.275938"
            },
            {
              "name": "VDB-275938 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.275938"
            },
            {
              "name": "Submit #394030 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.394030"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromMacFilterModify.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-27T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-27T15:17:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda O6 operateMacFilter frommacFilterModify stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8229",
        "datePublished": "2024-08-28T00:31:05.407Z",
        "dateReserved": "2024-08-27T13:12:15.785Z",
        "dateUpdated": "2024-08-28T15:54:55.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }