Search
Find a vulnerability
Search criteria
2 vulnerabilities found for nuc_kit_nuc7i5dnke by intel
CVE-2022-27229 (GCVE-0-2022-27229)
Vulnerability from nvd – Published: 2023-11-14 19:04 – Updated: 2024-08-30 18:25
VLAI
EPSS
VEX
Summary
Path transversal in some Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software before version 1.79.1.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
6.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-30 18:17 UTC
CWE
- escalation of privilege
- CWE-249 - Path transversal
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software |
Affected:
before version 1.79.1.1
|
|
| intel | nuc_hdmi_firmware_update_tool |
Affected:
0 , < 1.79.1.1
(custom)
cpe:2.3:a:intel:nuc_hdmi_firmware_update_tool:*:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i3dnhe |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i3dnhe:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i3dnke |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i3dnke:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i5dnhe |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i5dnhe:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i5dnke |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i5dnke:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i7dnhe |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i7dnhe:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i7dnke |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i7dnke:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:25:32.229Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:intel:nuc_hdmi_firmware_update_tool:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_hdmi_firmware_update_tool",
"vendor": "intel",
"versions": [
{
"lessThan": "1.79.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i3dnhe:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i3dnhe",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i3dnke:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i3dnke",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i5dnhe:-:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "nuc_kit_nuc7i5dnhe",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i5dnke:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i5dnke",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i7dnhe:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i7dnhe",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i7dnke:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i7dnke",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-27229",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-30T18:17:34.273725Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-30T18:25:32.791Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 1.79.1.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Path transversal in some Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software before version 1.79.1.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
},
{
"cweId": "CWE-249",
"description": "Path transversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T19:04:44.747Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-27229",
"datePublished": "2023-11-14T19:04:44.747Z",
"dateReserved": "2022-03-21T23:31:41.440Z",
"dateUpdated": "2024-08-30T18:25:32.791Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27229 (GCVE-0-2022-27229)
Vulnerability from cvelistv5 – Published: 2023-11-14 19:04 – Updated: 2024-08-30 18:25
VLAI
EPSS
VEX
Summary
Path transversal in some Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software before version 1.79.1.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
6.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-30 18:17 UTC
CWE
- escalation of privilege
- CWE-249 - Path transversal
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software |
Affected:
before version 1.79.1.1
|
|
| intel | nuc_hdmi_firmware_update_tool |
Affected:
0 , < 1.79.1.1
(custom)
cpe:2.3:a:intel:nuc_hdmi_firmware_update_tool:*:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i3dnhe |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i3dnhe:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i3dnke |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i3dnke:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i5dnhe |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i5dnhe:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i5dnke |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i5dnke:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i7dnhe |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i7dnhe:-:*:*:*:*:*:*:* |
|
| intel | nuc_kit_nuc7i7dnke |
Affected:
0 , < *
(custom)
cpe:2.3:h:intel:nuc_kit_nuc7i7dnke:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:25:32.229Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:intel:nuc_hdmi_firmware_update_tool:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_hdmi_firmware_update_tool",
"vendor": "intel",
"versions": [
{
"lessThan": "1.79.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i3dnhe:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i3dnhe",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i3dnke:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i3dnke",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i5dnhe:-:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "nuc_kit_nuc7i5dnhe",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i5dnke:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i5dnke",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i7dnhe:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i7dnhe",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:intel:nuc_kit_nuc7i7dnke:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nuc_kit_nuc7i7dnke",
"vendor": "intel",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-27229",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-30T18:17:34.273725Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-30T18:25:32.791Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 1.79.1.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Path transversal in some Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software before version 1.79.1.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
},
{
"cweId": "CWE-249",
"description": "Path transversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T19:04:44.747Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-27229",
"datePublished": "2023-11-14T19:04:44.747Z",
"dateReserved": "2022-03-21T23:31:41.440Z",
"dateUpdated": "2024-08-30T18:25:32.791Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}