Search criteria
14 vulnerabilities found for nuc_8_pro_kit_nuc8i3pnh_firmware by intel
CVE-2023-25771 (GCVE-0-2023-25771)
Vulnerability from nvd – Published: 2023-05-10 13:16 – Updated: 2025-01-27 18:08
VLAI?
Summary
Improper access control for some Intel(R) NUC BIOS firmware may allow a privileged user to potentially enable denial of service via local access.
Severity ?
5.8 (Medium)
CWE
- denial of service
- CWE-284 - Improper access control
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUC BIOS firmware |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:11.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25771",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T17:27:06.635615Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-27T18:08:44.812Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) NUC BIOS firmware",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control for some Intel(R) NUC BIOS firmware may allow a privileged user to potentially enable denial of service via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en"
},
{
"cweId": "CWE-284",
"description": "Improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-10T13:16:48.326Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-25771",
"datePublished": "2023-05-10T13:16:48.326Z",
"dateReserved": "2023-02-28T04:00:03.400Z",
"dateUpdated": "2025-01-27T18:08:44.812Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-33086 (GCVE-0-2021-33086)
Vulnerability from nvd – Published: 2021-11-17 18:59 – Updated: 2024-08-03 23:42
VLAI?
Summary
Out-of-bounds write in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable denial of service via local access.
Severity ?
No CVSS data available.
CWE
- denial of service
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:42:19.995Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds write in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable denial of service via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-17T18:59:09",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2021-33086",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Out-of-bounds write in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable denial of service via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "denial of service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2021-33086",
"datePublished": "2021-11-17T18:59:09",
"dateReserved": "2021-05-18T00:00:00",
"dateUpdated": "2024-08-03T23:42:19.995Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-0067 (GCVE-0-2021-0067)
Vulnerability from nvd – Published: 2021-06-09 19:07 – Updated: 2024-08-03 15:25
VLAI?
Summary
Improper access control in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T15:25:01.820Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\u0026nbsp;Improper access control in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-09T19:07:34",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2021-0067",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\u0026nbsp;Improper access control in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2021-0067",
"datePublished": "2021-06-09T19:07:34",
"dateReserved": "2020-10-22T00:00:00",
"dateUpdated": "2024-08-03T15:25:01.820Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-0054 (GCVE-0-2021-0054)
Vulnerability from nvd – Published: 2021-06-09 19:07 – Updated: 2024-08-03 15:25
VLAI?
Summary
Improper buffer restrictions in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T15:25:01.859Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-09T19:07:39",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2021-0054",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper buffer restrictions in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2021-0054",
"datePublished": "2021-06-09T19:07:39",
"dateReserved": "2020-10-22T00:00:00",
"dateUpdated": "2024-08-03T15:25:01.859Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-24525 (GCVE-0-2020-24525)
Vulnerability from nvd – Published: 2020-11-12 18:16 – Updated: 2024-08-04 15:12
VLAI?
Summary
Insecure inherited permissions in firmware update tool for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:12:09.087Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
},
{
"name": "20201116 Intel NUC - Local Privilege Escalation Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2020/Nov/26"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insecure inherited permissions in firmware update tool for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-16T11:06:07",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
},
{
"name": "20201116 Intel NUC - Local Privilege Escalation Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2020/Nov/26"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-24525",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insecure inherited permissions in firmware update tool for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
},
{
"name": "20201116 Intel NUC - Local Privilege Escalation Vulnerability",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2020/Nov/26"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-24525",
"datePublished": "2020-11-12T18:16:05",
"dateReserved": "2020-08-19T00:00:00",
"dateUpdated": "2024-08-04T15:12:09.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12337 (GCVE-0-2020-12337)
Vulnerability from nvd – Published: 2020-11-12 18:15 – Updated: 2024-08-04 11:56
VLAI?
Summary
Improper buffer restrictions in firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:51.397Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T18:15:58",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12337",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper buffer restrictions in firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12337",
"datePublished": "2020-11-12T18:15:58",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:51.397Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12336 (GCVE-0-2020-12336)
Vulnerability from nvd – Published: 2020-11-12 18:15 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insecure default variable initialization in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:52.019Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insecure default variable initialization in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T18:15:50",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12336",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insecure default variable initialization in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12336",
"datePublished": "2020-11-12T18:15:50",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:52.019Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25771 (GCVE-0-2023-25771)
Vulnerability from cvelistv5 – Published: 2023-05-10 13:16 – Updated: 2025-01-27 18:08
VLAI?
Summary
Improper access control for some Intel(R) NUC BIOS firmware may allow a privileged user to potentially enable denial of service via local access.
Severity ?
5.8 (Medium)
CWE
- denial of service
- CWE-284 - Improper access control
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUC BIOS firmware |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:11.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25771",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T17:27:06.635615Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-27T18:08:44.812Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) NUC BIOS firmware",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control for some Intel(R) NUC BIOS firmware may allow a privileged user to potentially enable denial of service via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en"
},
{
"cweId": "CWE-284",
"description": "Improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-10T13:16:48.326Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00777.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-25771",
"datePublished": "2023-05-10T13:16:48.326Z",
"dateReserved": "2023-02-28T04:00:03.400Z",
"dateUpdated": "2025-01-27T18:08:44.812Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-33086 (GCVE-0-2021-33086)
Vulnerability from cvelistv5 – Published: 2021-11-17 18:59 – Updated: 2024-08-03 23:42
VLAI?
Summary
Out-of-bounds write in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable denial of service via local access.
Severity ?
No CVSS data available.
CWE
- denial of service
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:42:19.995Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds write in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable denial of service via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-17T18:59:09",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2021-33086",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Out-of-bounds write in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable denial of service via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "denial of service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00567.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2021-33086",
"datePublished": "2021-11-17T18:59:09",
"dateReserved": "2021-05-18T00:00:00",
"dateUpdated": "2024-08-03T23:42:19.995Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-0054 (GCVE-0-2021-0054)
Vulnerability from cvelistv5 – Published: 2021-06-09 19:07 – Updated: 2024-08-03 15:25
VLAI?
Summary
Improper buffer restrictions in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T15:25:01.859Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-09T19:07:39",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2021-0054",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper buffer restrictions in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2021-0054",
"datePublished": "2021-06-09T19:07:39",
"dateReserved": "2020-10-22T00:00:00",
"dateUpdated": "2024-08-03T15:25:01.859Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-0067 (GCVE-0-2021-0067)
Vulnerability from cvelistv5 – Published: 2021-06-09 19:07 – Updated: 2024-08-03 15:25
VLAI?
Summary
Improper access control in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T15:25:01.820Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\u0026nbsp;Improper access control in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-09T19:07:34",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2021-0067",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\u0026nbsp;Improper access control in system firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00511.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2021-0067",
"datePublished": "2021-06-09T19:07:34",
"dateReserved": "2020-10-22T00:00:00",
"dateUpdated": "2024-08-03T15:25:01.820Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-24525 (GCVE-0-2020-24525)
Vulnerability from cvelistv5 – Published: 2020-11-12 18:16 – Updated: 2024-08-04 15:12
VLAI?
Summary
Insecure inherited permissions in firmware update tool for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:12:09.087Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
},
{
"name": "20201116 Intel NUC - Local Privilege Escalation Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2020/Nov/26"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insecure inherited permissions in firmware update tool for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-16T11:06:07",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
},
{
"name": "20201116 Intel NUC - Local Privilege Escalation Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2020/Nov/26"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-24525",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insecure inherited permissions in firmware update tool for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
},
{
"name": "20201116 Intel NUC - Local Privilege Escalation Vulnerability",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2020/Nov/26"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-24525",
"datePublished": "2020-11-12T18:16:05",
"dateReserved": "2020-08-19T00:00:00",
"dateUpdated": "2024-08-04T15:12:09.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12337 (GCVE-0-2020-12337)
Vulnerability from cvelistv5 – Published: 2020-11-12 18:15 – Updated: 2024-08-04 11:56
VLAI?
Summary
Improper buffer restrictions in firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:51.397Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T18:15:58",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12337",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper buffer restrictions in firmware for some Intel(R) NUCs may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12337",
"datePublished": "2020-11-12T18:15:58",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:51.397Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12336 (GCVE-0-2020-12336)
Vulnerability from cvelistv5 – Published: 2020-11-12 18:15 – Updated: 2024-08-04 11:56
VLAI?
Summary
Insecure default variable initialization in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity ?
No CVSS data available.
CWE
- escalation of privilege
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUCs |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:56:52.019Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) NUCs",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insecure default variable initialization in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-12T18:15:50",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2020-12336",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) NUCs",
"version": {
"version_data": [
{
"version_value": "See references"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insecure default variable initialization in firmware for some Intel(R) NUCs may allow an authenticated user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "escalation of privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00414"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2020-12336",
"datePublished": "2020-11-12T18:15:50",
"dateReserved": "2020-04-28T00:00:00",
"dateUpdated": "2024-08-04T11:56:52.019Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}