Search

Find a vulnerability

Search criteria

    44 vulnerabilities found for myREX24.virtual by Helmholz

    FKIE_CVE-2023-4834

    Vulnerability from fkie_nvd - Published: 2023-10-16 09:15 - Updated: 2026-06-17 06:38
    Summary
    In Red Lion Europe mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an improperly implemented access validation allows an authenticated, low privileged attacker to gain read access to limited, non-critical device information in his account he should not have access to.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B75F1E4-3DFA-4163-A9C7-8CF5C9A78562",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "885E9E11-89FE-468F-8160-EC3B21E6CA77",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2029F9FB-397A-490D-A86F-B2B39C516A79",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F77AC2B-5B57-4CFF-A4F1-AA8E6B1B8C3B",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Red Lion Europe\u00a0mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u00a0improperly implemented access validation allows an authenticated, low privileged\u00a0attacker to gain read access to limited, non-critical device information in his account he should not have access to.\n\n\n\n\t\t\t\t\t\n\n\n\t\t\t\t\n\n\n\t\t\t\n\n\n\t\t\n\n\n\t\n"
        },
        {
          "lang": "es",
          "value": "En Red Lion Europe mbCONNECT24 y mymbCONNECT24 y Helmholz myREX24 y myREX24.virtual hasta la versi\u00f3n 2.14.2 incluida, una validaci\u00f3n de acceso implementada incorrectamente permite a un atacante autenticado y con pocos privilegios obtener acceso de lectura a informaci\u00f3n limitada y no cr\u00edtica del dispositivo a la que no deber\u00eda tener acceso en su cuenta."
        }
      ],
      "id": "CVE-2023-4834",
      "lastModified": "2026-06-17T06:38:42.783",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-4834",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-09-16T18:16:53.810599Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-10-16T09:15:11.830",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2022-22520

    Vulnerability from fkie_nvd - Published: 2022-09-14 14:15 - Updated: 2026-06-17 04:28
    Summary
    A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
        },
        {
          "lang": "es",
          "value": "Un atacante remoto no autenticado puede enumerar usuarios v\u00e1lidos mediante el env\u00edo de peticiones espec\u00edficas al webservice de la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta v2.11.2"
        }
      ],
      "id": "CVE-2022-22520",
      "lastModified": "2026-06-17T04:28:31.333",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2022-09-14T14:15:12.427",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-204"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-34574

    Vulnerability from fkie_nvd - Published: 2021-08-02 11:15 - Updated: 2026-06-17 03:56
    Summary
    In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
        },
        {
          "lang": "es",
          "value": "En MB connect line mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2 un atacante autenticado puede cambiar la contrase\u00f1a de su cuenta por una nueva que viole la pol\u00edtica de contrase\u00f1as interceptando y modificando la petici\u00f3n que se env\u00eda al servidor."
        }
      ],
      "id": "CVE-2021-34574",
      "lastModified": "2026-06-17T03:56:09.380",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2021-08-02T11:15:11.350",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-669"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-669"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-35570

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. An unauthenticated attacker is able to access files (that should have been restricted) via forceful browsing.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. An unauthenticated attacker is able to access files (that should have been restricted) via forceful browsing."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual hasta la versi\u00f3n 2.11.2. Un atacante no autenticado es capaz de acceder a archivos (que deber\u00edan haber sido restringidos) a trav\u00e9s de la navegaci\u00f3n forzada."
        }
      ],
      "id": "CVE-2020-35570",
      "lastModified": "2026-06-17T03:13:57.467",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.830",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-425"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35568

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An incomplete filter applied to a database response allows an authenticated attacker to gain non-public information about other users and devices in the account.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An incomplete filter applied to a database response allows an authenticated attacker to gain non-public information about other users and devices in the account."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2. Un filtro incompleto aplicado a una respuesta de la base de datos permite a un atacante autenticado obtener informaci\u00f3n no p\u00fablica sobre otros usuarios y dispositivos de la cuenta.\n"
        }
      ],
      "id": "CVE-2020-35568",
      "lastModified": "2026-06-17T03:13:57.210",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.707",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35566

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An attacker can read arbitrary JSON files via Local File Inclusion.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An attacker can read arbitrary JSON files via Local File Inclusion."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2. Un atacante puede leer archivos JSON arbitrarios a trav\u00e9s de la inclusi\u00f3n de archivos locales."
        }
      ],
      "id": "CVE-2020-35566",
      "lastModified": "2026-06-17T03:13:56.963",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.567",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-706"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35561

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. There is an SSRF in the HA module allowing an unauthenticated attacker to scan for open ports.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. There is an SSRF in the HA module allowing an unauthenticated attacker to scan for open ports."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2. Existe un SSRF en el m\u00f3dulo HA que permite a un atacante no autentificado escanear puertos abiertos."
        }
      ],
      "id": "CVE-2020-35561",
      "lastModified": "2026-06-17T03:13:56.470",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.317",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-918"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35558

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. There is an SSRF in the in the MySQL access check, allowing an attacker to scan for open ports and gain some information about possible credentials.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. There is an SSRF in the in the MySQL access check, allowing an attacker to scan for open ports and gain some information about possible credentials."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual hasta la versi\u00f3n 2.11.2. Hay un SSRF en la en la comprobaci\u00f3n de acceso a MySQL, lo que permite a un atacante escanear los puertos abiertos y obtener alguna informaci\u00f3n sobre posibles credenciales"
        }
      ],
      "id": "CVE-2020-35558",
      "lastModified": "2026-06-17T03:13:55.090",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.113",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-918"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35557

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 allows a logged in user to see devices in the account he should not have access to due to improper use of access validation.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 allows a logged in user to see devices in the account he should not have access to due to improper use of access validation."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2 permite a un usuario conectado ver dispositivos en la cuenta a la que no deber\u00eda tener acceso debido al uso incorrecto de la validaci\u00f3n de acceso"
        }
      ],
      "id": "CVE-2020-35557",
      "lastModified": "2026-06-17T03:13:54.953",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.050",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-12527

    Vulnerability from fkie_nvd - Published: 2021-03-02 22:15 - Updated: 2026-06-17 02:51
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2.6.2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2.6.2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.11.2"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions."
        },
        {
          "lang": "es",
          "value": "Se ha descubierto un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2. Una validaci\u00f3n de acceso inadecuada permite a un usuario conectado apagar o reiniciar los dispositivos de su cuenta sin tener los permisos correspondientes"
        }
      ],
      "id": "CVE-2020-12527",
      "lastModified": "2026-06-17T02:51:58.707",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 6.8,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 6.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2021-03-02T22:15:12.387",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    CVE-2025-3092 (GCVE-0-2025-3092)

    Vulnerability from nvd – Published: 2025-06-24 08:14 – Updated: 2025-06-24 13:55
    VLAI
    Title
    MB connect line: Observable response discrepancy in mbCONNECT24/mymbCONNECT24
    Summary
    An unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-24 13:55 UTC
    CWE
    • CWE-204 - Observable Response Discrepancy
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3092",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-24T13:55:22.243364Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-24T13:55:34.477Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Peter Husted Simonsen"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Irwin Przeperski"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Eviden"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-204",
                  "description": "CWE-204:Observable Response Discrepancy",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-24T08:14:31.864Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-035"
            },
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-038"
            }
          ],
          "source": {
            "advisory": "VDE-2025-035",
            "defect": [
              "CERT@VDE#641772"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line: Observable response discrepancy in mbCONNECT24/mymbCONNECT24",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3092",
        "datePublished": "2025-06-24T08:14:31.864Z",
        "dateReserved": "2025-04-01T13:41:23.509Z",
        "dateUpdated": "2025-06-24T13:55:34.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3091 (GCVE-0-2025-3091)

    Vulnerability from nvd – Published: 2025-06-24 08:10 – Updated: 2025-06-24 13:56
    VLAI
    Title
    MB connect line: Authorization bypass in mbCONNECT24/mymbCONNECT24
    Summary
    An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-24 13:55 UTC
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3091",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-24T13:55:50.726894Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-24T13:56:13.121Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Peter Husted Simonsen"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Irwin Przeperski"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Eviden"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password."
                }
              ],
              "value": "An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-24T08:10:29.717Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-035"
            },
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-038"
            }
          ],
          "source": {
            "advisory": "VDE-2025-035",
            "defect": [
              "CERT@VDE#641772"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line: Authorization bypass in mbCONNECT24/mymbCONNECT24",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3091",
        "datePublished": "2025-06-24T08:10:29.717Z",
        "dateReserved": "2025-04-01T13:41:22.429Z",
        "dateUpdated": "2025-06-24T13:56:13.121Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3090 (GCVE-0-2025-3090)

    Vulnerability from nvd – Published: 2025-06-24 08:05 – Updated: 2025-06-24 14:18
    VLAI
    Title
    MB connect line: Missing Authentication in mbCONNECT24/mymbCONNECT24
    Summary
    An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-24 14:17 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3090",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-24T14:17:56.862943Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-24T14:18:57.831Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function."
                }
              ],
              "value": "An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-24T08:05:15.547Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-034"
            },
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-037"
            }
          ],
          "source": {
            "advisory": "VDE-2025-034",
            "defect": [
              "CERT@VDE#641771"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line: Missing Authentication in mbCONNECT24/mymbCONNECT24",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3090",
        "datePublished": "2025-06-24T08:05:15.547Z",
        "dateReserved": "2025-04-01T13:41:20.503Z",
        "dateUpdated": "2025-06-24T14:18:57.831Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45273 (GCVE-0-2024-45273)

    Vulnerability from nvd – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:47
    VLAI
    Title
    MB connect line/Helmholz: Weak encryption of configuration file
    Summary
    An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-15 18:22 UTC
    CWE
    • CWE-261 - Weak Encoding for Password
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    MB connect line mbNET/mbNET.rokey Affected: 0.0.0 , ≤ 8.2.0 (semver)
    Create a notification for this product.
    MB connect line mbNET HW1 Affected: 0.0.0 , ≤ 5.1.11 (semver)
    Create a notification for this product.
    MB connect line mbSPIDER Affected: 0.0.0 , ≤ 2.6.5 (semver)
    Create a notification for this product.
    MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ <= 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX200/250 Affected: 0.0.0 , ≤ <= 8.2.0 (semver)
    Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX300 Affected: 0.0.0 , ≤ <= 5.1.11 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_mbnet.rokey Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_hw1 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbspider Affected: 0 , ≤ 2.6.5 (semver)
        cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mymbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex100 Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_200 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex250 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24_v2 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24.virtual Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex300 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_mbnet.rokey",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_hw1",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbspider",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.6.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mymbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex100",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_200",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex250",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24_v2",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24.virtual",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex300",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45273",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T18:22:26.955543Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T18:31:20.013Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:47:04.737Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET HW1",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbSPIDER",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.6.5",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX300",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-261",
                  "description": "CWE-261: Weak Encoding for Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:27:52.208Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066, VDE-2024-068, VDE-2024-069",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641695",
              "CERT@VDE#641692",
              "CERT@VDE#641696"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Weak encryption of configuration file",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45273",
        "datePublished": "2024-10-15T10:27:52.208Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:47:04.737Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45272 (GCVE-0-2024-45272)

    Vulnerability from nvd – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:36
    VLAI
    Title
    MB connect line/Helmholz: Generation of weak passwords vulnerability
    Summary
    An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-15 13:40 UTC
    CWE
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Vendor Product Version
    MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    mbconnectline mbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mymbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24_v2 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24.virtual Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mymbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24_v2",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24.virtual",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45272",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:40:14.338031Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:43:55.942Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:36:22.123Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-061.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1391",
                  "description": "CWE-1391: Use of Weak Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:27:32.688Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
            }
          ],
          "source": {
            "advisory": "VDE-2024-068, VDE-2024-069",
            "defect": [
              "CERT@VDE#641695",
              "CERT@VDE#641696"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Generation of weak passwords vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45272",
        "datePublished": "2024-10-15T10:27:32.688Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:36:22.123Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-4834 (GCVE-0-2023-4834)

    Vulnerability from nvd – Published: 2023-10-16 08:40 – Updated: 2024-09-16 18:17
    VLAI
    Summary
    In Red Lion Europe mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an improperly implemented access validation allows an authenticated, low privileged attacker to gain read access to limited, non-critical device information in his account he should not have access to.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-16 18:16 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Date Public
    2023-10-16 08:40
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:38:00.778Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-4834",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-16T18:16:53.810599Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-16T18:17:07.881Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2023-10-16T08:40:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eIn \u003cspan style=\"background-color: rgb(249, 250, 251);\"\u003eRed Lion Europe\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(249, 250, 251);\"\u003embCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u0026nbsp;\u003c/span\u003eimproperly implemented access validation \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallows an authenticated, \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003elow privileged\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;attacker to gain read access to limited, non-critical device information in his account he should not have access to.\u003c/span\u003e\n\u003c/p\u003e\n\t\t\t\t\t\u003c/div\u003e\n\t\t\t\t\u003c/div\u003e\n\t\t\t\u003c/div\u003e\n\t\t\u003c/div\u003e\n\t\n"
                }
              ],
              "value": "In Red Lion Europe\u00a0mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u00a0improperly implemented access validation allows an authenticated, low privileged\u00a0attacker to gain read access to limited, non-critical device information in his account he should not have access to.\n\n\n\n\t\t\t\t\t\n\n\n\t\t\t\t\n\n\n\t\t\t\n\n\n\t\t\n\n\n\t\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269 Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-16T08:59:23.795Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64587"
            ],
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-4834",
        "datePublished": "2023-10-16T08:40:13.064Z",
        "dateReserved": "2023-09-08T07:54:38.764Z",
        "dateUpdated": "2024-09-16T18:17:07.881Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-1779 (GCVE-0-2023-1779)

    Vulnerability from nvd – Published: 2023-06-06 10:07 – Updated: 2025-01-07 19:19
    VLAI
    Title
    Helmholz and MB Connect Line: Account takeover via password reset in multiple products
    Summary
    Exposure of Sensitive Information to an unauthorized actor vulnerability in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual in versions <=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-07 19:17 UTC
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    MB Connect Line mbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    MB Connect Line mymbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24 Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:57:25.020Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-07T19:17:38.403913Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-07T19:19:11.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Helmholz GmbH \u0026 Co. KG"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Exposure of Sensitive Information to an unauthorized actor vulnerability\u0026nbsp;in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual in versions \u0026lt;=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information."
                }
              ],
              "value": "Exposure of Sensitive Information to an unauthorized actor vulnerability\u00a0in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual in versions \u003c=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-02T05:30:25.424Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-002",
            "defect": [
              "CERT@VDE#64404"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Helmholz and MB Connect Line: Account takeover via password reset in multiple products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-1779",
        "datePublished": "2023-06-06T10:07:35.354Z",
        "dateReserved": "2023-03-31T13:00:50.757Z",
        "dateUpdated": "2025-01-07T19:19:11.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0985 (GCVE-0-2023-0985)

    Vulnerability from nvd – Published: 2023-06-06 10:06 – Updated: 2025-01-07 19:20
    VLAI
    Title
    Helmholz and MB Connect Line: Account takeover via password reset in multiple products
    Summary
    An Authorization Bypass vulnerability was found in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual version <= 2.13.3. An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-07 19:19 UTC
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    MB Connect Line mbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    MB Connect Line mymbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24 Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Date Public
    2023-05-15 10:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:32:45.981Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0985",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-07T19:19:39.189272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-07T19:20:21.167Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hussein Alsharafi"
            }
          ],
          "datePublic": "2023-05-15T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An Authorization Bypass vulnerability was found in MB Connect Lines\u0026nbsp;mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual version \u0026lt;= 2.13.3.\u0026nbsp;An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account."
                }
              ],
              "value": "An Authorization Bypass vulnerability was found in MB Connect Lines\u00a0mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual version \u003c= 2.13.3.\u00a0An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-06T10:06:48.102Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-002",
            "defect": [
              "CERT@VDE#64404"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Helmholz and MB Connect Line: Account takeover via password reset in multiple products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-0985",
        "datePublished": "2023-06-06T10:06:48.102Z",
        "dateReserved": "2023-02-23T14:11:49.473Z",
        "dateUpdated": "2025-01-07T19:20:21.167Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22520 (GCVE-0-2022-22520)

    Vulnerability from nvd – Published: 2022-09-14 14:05 – Updated: 2024-09-17 04:14
    VLAI
    Title
    User enumeration vulnerability in MB connect line and Helmholz products
    Summary
    A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2.
    CWE
    • CWE-204 - Response Discrepancy Information Exposure
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Date Public
    2022-09-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.402Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "SySS GmbH reported this vulnerability to Helmholz.  Helmholz reported this vulnerability to MB connect line. CERT@VDE coordinated with Helmholz \u0026 MB connect line."
            }
          ],
          "datePublic": "2022-09-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-204",
                  "description": "CWE-204 Response Discrepancy Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-14T14:05:29.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update to Version 2.12.1"
            }
          ],
          "source": {
            "advisory": "VDE-2022-011",
            "discovery": "EXTERNAL"
          },
          "title": "User enumeration vulnerability in MB connect line and Helmholz products",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
              "ID": "CVE-2022-22520",
              "STATE": "PUBLIC",
              "TITLE": "User enumeration vulnerability in MB connect line and Helmholz products"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "mymbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "mbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "MB connect line"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myREX24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "myREX24.virtual",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Helmholz"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "SySS GmbH reported this vulnerability to Helmholz.  Helmholz reported this vulnerability to MB connect line. CERT@VDE coordinated with Helmholz \u0026 MB connect line."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-204 Response Discrepancy Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
                },
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-011",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update to Version 2.12.1"
              }
            ],
            "source": {
              "advisory": "VDE-2022-011",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22520",
        "datePublished": "2022-09-14T14:05:30.024Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T04:14:21.926Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34574 (GCVE-0-2021-34574)

    Vulnerability from nvd – Published: 2021-08-02 10:24 – Updated: 2024-09-16 18:14
    VLAI
    Title
    Password policy evasion in products of MB connect line and Helmholz
    Summary
    In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server.
    CWE
    • CWE-669 - Incorrect Resource Transfer Between Spheres
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Date Public
    2022-09-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:19:46.604Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "OTORIO reported the vulnerabilities to MB connect line."
            }
          ],
          "datePublic": "2022-09-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-669",
                  "description": "CWE-669 Incorrect Resource Transfer Between Spheres",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-14T14:05:29.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update to version 2.12.1"
            }
          ],
          "source": {
            "advisory": "VDE-2021-030, VDE-2022-039",
            "discovery": "EXTERNAL"
          },
          "title": "Password policy evasion in products of MB connect line and Helmholz",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
              "ID": "CVE-2021-34574",
              "STATE": "PUBLIC",
              "TITLE": "Password policy evasion in products of MB connect line and Helmholz"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "mymbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "mbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "MB connect line"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myREX24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "myREX24.virtual",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Helmholz"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "OTORIO reported the vulnerabilities to MB connect line."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-669 Incorrect Resource Transfer Between Spheres"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
                },
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2021-030",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update to version 2.12.1"
              }
            ],
            "source": {
              "advisory": "VDE-2021-030, VDE-2022-039",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34574",
        "datePublished": "2021-08-02T10:24:31.932Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:14:15.495Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3092 (GCVE-0-2025-3092)

    Vulnerability from cvelistv5 – Published: 2025-06-24 08:14 – Updated: 2025-06-24 13:55
    VLAI
    Title
    MB connect line: Observable response discrepancy in mbCONNECT24/mymbCONNECT24
    Summary
    An unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-24 13:55 UTC
    CWE
    • CWE-204 - Observable Response Discrepancy
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3092",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-24T13:55:22.243364Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-24T13:55:34.477Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Peter Husted Simonsen"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Irwin Przeperski"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Eviden"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-204",
                  "description": "CWE-204:Observable Response Discrepancy",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-24T08:14:31.864Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-035"
            },
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-038"
            }
          ],
          "source": {
            "advisory": "VDE-2025-035",
            "defect": [
              "CERT@VDE#641772"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line: Observable response discrepancy in mbCONNECT24/mymbCONNECT24",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3092",
        "datePublished": "2025-06-24T08:14:31.864Z",
        "dateReserved": "2025-04-01T13:41:23.509Z",
        "dateUpdated": "2025-06-24T13:55:34.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3091 (GCVE-0-2025-3091)

    Vulnerability from cvelistv5 – Published: 2025-06-24 08:10 – Updated: 2025-06-24 13:56
    VLAI
    Title
    MB connect line: Authorization bypass in mbCONNECT24/mymbCONNECT24
    Summary
    An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-24 13:55 UTC
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3091",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-24T13:55:50.726894Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-24T13:56:13.121Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.16.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Peter Husted Simonsen"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Irwin Przeperski"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Eviden"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password."
                }
              ],
              "value": "An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-24T08:10:29.717Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-035"
            },
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-038"
            }
          ],
          "source": {
            "advisory": "VDE-2025-035",
            "defect": [
              "CERT@VDE#641772"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line: Authorization bypass in mbCONNECT24/mymbCONNECT24",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3091",
        "datePublished": "2025-06-24T08:10:29.717Z",
        "dateReserved": "2025-04-01T13:41:22.429Z",
        "dateUpdated": "2025-06-24T13:56:13.121Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3090 (GCVE-0-2025-3090)

    Vulnerability from cvelistv5 – Published: 2025-06-24 08:05 – Updated: 2025-06-24 14:18
    VLAI
    Title
    MB connect line: Missing Authentication in mbCONNECT24/mymbCONNECT24
    Summary
    An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-24 14:17 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3090",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-24T14:17:56.862943Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-24T14:18:57.831Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.18.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function."
                }
              ],
              "value": "An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-24T08:05:15.547Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-034"
            },
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-037"
            }
          ],
          "source": {
            "advisory": "VDE-2025-034",
            "defect": [
              "CERT@VDE#641771"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line: Missing Authentication in mbCONNECT24/mymbCONNECT24",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3090",
        "datePublished": "2025-06-24T08:05:15.547Z",
        "dateReserved": "2025-04-01T13:41:20.503Z",
        "dateUpdated": "2025-06-24T14:18:57.831Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45273 (GCVE-0-2024-45273)

    Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:47
    VLAI
    Title
    MB connect line/Helmholz: Weak encryption of configuration file
    Summary
    An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-15 18:22 UTC
    CWE
    • CWE-261 - Weak Encoding for Password
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    MB connect line mbNET/mbNET.rokey Affected: 0.0.0 , ≤ 8.2.0 (semver)
    Create a notification for this product.
    MB connect line mbNET HW1 Affected: 0.0.0 , ≤ 5.1.11 (semver)
    Create a notification for this product.
    MB connect line mbSPIDER Affected: 0.0.0 , ≤ 2.6.5 (semver)
    Create a notification for this product.
    MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ <= 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX200/250 Affected: 0.0.0 , ≤ <= 8.2.0 (semver)
    Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX300 Affected: 0.0.0 , ≤ <= 5.1.11 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_mbnet.rokey Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_hw1 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbspider Affected: 0 , ≤ 2.6.5 (semver)
        cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mymbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex100 Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_200 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex250 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24_v2 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24.virtual Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex300 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_mbnet.rokey",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_hw1",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbspider",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.6.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mymbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex100",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_200",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex250",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24_v2",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24.virtual",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex300",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45273",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T18:22:26.955543Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T18:31:20.013Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:47:04.737Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET HW1",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbSPIDER",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.6.5",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX300",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-261",
                  "description": "CWE-261: Weak Encoding for Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:27:52.208Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066, VDE-2024-068, VDE-2024-069",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641695",
              "CERT@VDE#641692",
              "CERT@VDE#641696"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Weak encryption of configuration file",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45273",
        "datePublished": "2024-10-15T10:27:52.208Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:47:04.737Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45272 (GCVE-0-2024-45272)

    Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:36
    VLAI
    Title
    MB connect line/Helmholz: Generation of weak passwords vulnerability
    Summary
    An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-15 13:40 UTC
    CWE
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Vendor Product Version
    MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    mbconnectline mbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mymbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24_v2 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24.virtual Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mymbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24_v2",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24.virtual",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45272",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:40:14.338031Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:43:55.942Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:36:22.123Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-061.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1391",
                  "description": "CWE-1391: Use of Weak Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:27:32.688Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
            }
          ],
          "source": {
            "advisory": "VDE-2024-068, VDE-2024-069",
            "defect": [
              "CERT@VDE#641695",
              "CERT@VDE#641696"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Generation of weak passwords vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45272",
        "datePublished": "2024-10-15T10:27:32.688Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:36:22.123Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-4834 (GCVE-0-2023-4834)

    Vulnerability from cvelistv5 – Published: 2023-10-16 08:40 – Updated: 2024-09-16 18:17
    VLAI
    Summary
    In Red Lion Europe mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an improperly implemented access validation allows an authenticated, low privileged attacker to gain read access to limited, non-critical device information in his account he should not have access to.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-16 18:16 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Date Public
    2023-10-16 08:40
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:38:00.778Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-4834",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-16T18:16:53.810599Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-16T18:17:07.881Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2023-10-16T08:40:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eIn \u003cspan style=\"background-color: rgb(249, 250, 251);\"\u003eRed Lion Europe\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(249, 250, 251);\"\u003embCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u0026nbsp;\u003c/span\u003eimproperly implemented access validation \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallows an authenticated, \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003elow privileged\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;attacker to gain read access to limited, non-critical device information in his account he should not have access to.\u003c/span\u003e\n\u003c/p\u003e\n\t\t\t\t\t\u003c/div\u003e\n\t\t\t\t\u003c/div\u003e\n\t\t\t\u003c/div\u003e\n\t\t\u003c/div\u003e\n\t\n"
                }
              ],
              "value": "In Red Lion Europe\u00a0mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u00a0improperly implemented access validation allows an authenticated, low privileged\u00a0attacker to gain read access to limited, non-critical device information in his account he should not have access to.\n\n\n\n\t\t\t\t\t\n\n\n\t\t\t\t\n\n\n\t\t\t\n\n\n\t\t\n\n\n\t\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269 Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-16T08:59:23.795Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64587"
            ],
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-4834",
        "datePublished": "2023-10-16T08:40:13.064Z",
        "dateReserved": "2023-09-08T07:54:38.764Z",
        "dateUpdated": "2024-09-16T18:17:07.881Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-1779 (GCVE-0-2023-1779)

    Vulnerability from cvelistv5 – Published: 2023-06-06 10:07 – Updated: 2025-01-07 19:19
    VLAI
    Title
    Helmholz and MB Connect Line: Account takeover via password reset in multiple products
    Summary
    Exposure of Sensitive Information to an unauthorized actor vulnerability in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual in versions <=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-07 19:17 UTC
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    MB Connect Line mbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    MB Connect Line mymbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24 Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:57:25.020Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-07T19:17:38.403913Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-07T19:19:11.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Helmholz GmbH \u0026 Co. KG"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Exposure of Sensitive Information to an unauthorized actor vulnerability\u0026nbsp;in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual in versions \u0026lt;=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information."
                }
              ],
              "value": "Exposure of Sensitive Information to an unauthorized actor vulnerability\u00a0in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual in versions \u003c=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-02T05:30:25.424Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-002",
            "defect": [
              "CERT@VDE#64404"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Helmholz and MB Connect Line: Account takeover via password reset in multiple products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-1779",
        "datePublished": "2023-06-06T10:07:35.354Z",
        "dateReserved": "2023-03-31T13:00:50.757Z",
        "dateUpdated": "2025-01-07T19:19:11.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0985 (GCVE-0-2023-0985)

    Vulnerability from cvelistv5 – Published: 2023-06-06 10:06 – Updated: 2025-01-07 19:20
    VLAI
    Title
    Helmholz and MB Connect Line: Account takeover via password reset in multiple products
    Summary
    An Authorization Bypass vulnerability was found in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual version <= 2.13.3. An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-07 19:19 UTC
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    MB Connect Line mbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    MB Connect Line mymbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24 Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0 , ≤ 2.13.3 (semver)
    Create a notification for this product.
    Date Public
    2023-05-15 10:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:32:45.981Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0985",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-07T19:19:39.189272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-07T19:20:21.167Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hussein Alsharafi"
            }
          ],
          "datePublic": "2023-05-15T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An Authorization Bypass vulnerability was found in MB Connect Lines\u0026nbsp;mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual version \u0026lt;= 2.13.3.\u0026nbsp;An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account."
                }
              ],
              "value": "An Authorization Bypass vulnerability was found in MB Connect Lines\u00a0mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual version \u003c= 2.13.3.\u00a0An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-06T10:06:48.102Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-002",
            "defect": [
              "CERT@VDE#64404"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Helmholz and MB Connect Line: Account takeover via password reset in multiple products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-0985",
        "datePublished": "2023-06-06T10:06:48.102Z",
        "dateReserved": "2023-02-23T14:11:49.473Z",
        "dateUpdated": "2025-01-07T19:20:21.167Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22520 (GCVE-0-2022-22520)

    Vulnerability from cvelistv5 – Published: 2022-09-14 14:05 – Updated: 2024-09-17 04:14
    VLAI
    Title
    User enumeration vulnerability in MB connect line and Helmholz products
    Summary
    A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2.
    CWE
    • CWE-204 - Response Discrepancy Information Exposure
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Date Public
    2022-09-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.402Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "SySS GmbH reported this vulnerability to Helmholz.  Helmholz reported this vulnerability to MB connect line. CERT@VDE coordinated with Helmholz \u0026 MB connect line."
            }
          ],
          "datePublic": "2022-09-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-204",
                  "description": "CWE-204 Response Discrepancy Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-14T14:05:29.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update to Version 2.12.1"
            }
          ],
          "source": {
            "advisory": "VDE-2022-011",
            "discovery": "EXTERNAL"
          },
          "title": "User enumeration vulnerability in MB connect line and Helmholz products",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
              "ID": "CVE-2022-22520",
              "STATE": "PUBLIC",
              "TITLE": "User enumeration vulnerability in MB connect line and Helmholz products"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "mymbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "mbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "MB connect line"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myREX24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "myREX24.virtual",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Helmholz"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "SySS GmbH reported this vulnerability to Helmholz.  Helmholz reported this vulnerability to MB connect line. CERT@VDE coordinated with Helmholz \u0026 MB connect line."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-204 Response Discrepancy Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
                },
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-011",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update to Version 2.12.1"
              }
            ],
            "source": {
              "advisory": "VDE-2022-011",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22520",
        "datePublished": "2022-09-14T14:05:30.024Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T04:14:21.926Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34574 (GCVE-0-2021-34574)

    Vulnerability from cvelistv5 – Published: 2021-08-02 10:24 – Updated: 2024-09-16 18:14
    VLAI
    Title
    Password policy evasion in products of MB connect line and Helmholz
    Summary
    In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server.
    CWE
    • CWE-669 - Incorrect Resource Transfer Between Spheres
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Date Public
    2022-09-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:19:46.604Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "OTORIO reported the vulnerabilities to MB connect line."
            }
          ],
          "datePublic": "2022-09-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-669",
                  "description": "CWE-669 Incorrect Resource Transfer Between Spheres",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-14T14:05:29.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update to version 2.12.1"
            }
          ],
          "source": {
            "advisory": "VDE-2021-030, VDE-2022-039",
            "discovery": "EXTERNAL"
          },
          "title": "Password policy evasion in products of MB connect line and Helmholz",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
              "ID": "CVE-2021-34574",
              "STATE": "PUBLIC",
              "TITLE": "Password policy evasion in products of MB connect line and Helmholz"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "mymbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "mbCONNECT24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "MB connect line"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myREX24",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "myREX24.virtual",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "2",
                                "version_value": "2.11.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Helmholz"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "OTORIO reported the vulnerabilities to MB connect line."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-669 Incorrect Resource Transfer Between Spheres"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
                },
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2021-030",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update to version 2.12.1"
              }
            ],
            "source": {
              "advisory": "VDE-2021-030, VDE-2022-039",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34574",
        "datePublished": "2021-08-02T10:24:31.932Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:14:15.495Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }