Search
Find a vulnerability
Search criteria
2 vulnerabilities found for mt20_mobile_thin_client_firmware by hp
CVE-2022-27540 (GCVE-0-2022-27540)
Vulnerability from nvd – Published: 2024-06-28 19:00 – Updated: 2024-08-22 14:52
VLAI
Summary
A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27540",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T15:47:15.827287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T14:52:53.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-28T19:00:28.307Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27540",
"datePublished": "2024-06-28T19:00:28.307Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2024-08-22T14:52:53.925Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27540 (GCVE-0-2022-27540)
Vulnerability from cvelistv5 – Published: 2024-06-28 19:00 – Updated: 2024-08-22 14:52
VLAI
Summary
A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27540",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T15:47:15.827287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T14:52:53.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-28T19:00:28.307Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27540",
"datePublished": "2024-06-28T19:00:28.307Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2024-08-22T14:52:53.925Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}